TSL.R.020 ribbon sensor faucet Read and save these instructions WARNING To reduce the risk of fire, electric shock or injury to persons, observe the following: Use this unit in the manner intended by the manufacturer. If you have questions, contact the manufacturer This equipment should be installed in a way that ensures all electrical parts are kept dry.
Page 6
technical data FRONT SIDE 7-5/16" 2-1/8" 4-31/32" Default S ensor Range 4-3/4" Ø 1-11/32" Through Hole 3/8" MIN 1-3/8" MAX 2-23/32" Ø 1-1/4" MAX Length 11-13/16" 6" 1/2" BS P Battery Power S upply Mains Power S upply TSL.R.020 RIBBON SENSOR FAUCET MANUAL...
Sinks Use of a The Splash Lab sink is recommended when used in conjunction with any of the The Splash Lab Ribbon taps. When using other sinks, ensure that holes and appropriate mounting points are created in accordance with the diagram below.
how to install Ensure internal anti-rotation ring (D) and Position tap on sink deck through a the gasket (E) are fitted into the recesses Ø 1 1/4” hole and ensure the tap is angled in the Ribbon sensor tap head (A). These pointing in the required direction.
Page 9
This tap can be fitted to a variety of sink types: The Splash Lab Approved Sink a. When using an approved The Splash Lab Ribbon sink, there will be a recess available for the under-sink anti- rotation plate (F). No fixings are required at this stage.
Page 10
how to install Attach the Ribbon fixing nut (G) with the flat surface towards the sink. We recommend tightening to 15-20 Nm, however this is subject to the sink material and install situation. Fit the end of the flexi-hose onto the outlet of the solenoid, ensuring that the flow restrictor is in place, between the fixing nut and the solenoid valve.
Page 11
the complete system Water Aerator Ribbon sensor faucet head Mains power supply Battery supply Solenoid and cable Flow restrictor Mains Water Supply Flexi-Hose 110-240 Volt Mains Supply TSL.R.020 RIBBON SENSOR FAUCET MANUAL...
resetting the sensor Firstly disconnect the Ribbon Tap head Look under the tap at the sensor near from the Power unit. Wait a minimum of 4 the nozzle. You should see a flashing red seconds and reconnect the power. light. When you see the light position your hand within 2”...
Page 13
When the light stops flashing move your When the light goes out the new hand down to the desired activation detection distance is set. Test the system position and hold. and repeat from step 1 until the tap works as required. *Remove reflective clothing during installation TSL.R.020 RIBBON SENSOR FAUCET MANUAL...
The Ribbon system has been developed to accommodate for this maintenance yet all work should be done by a trained member of an approved maintenance team. For more information, contact The Splash Lab. cleaning External parts should be cleaned with a soft cloth and a mild solution of soapy water as part of the regular cleaning regime.
Should a replacement mains power supply be required it is imperative that an identical type is used. Contact The Splash Lab for further information. product identification A unique product identification code can be found on the product tag attached to the water hose.
Check that transformer is operating and supplying 6 volts Replace battery on battery powered versions Sensor range is incorrect Adjust sensor settings (see page 10 and 11, or contact The Splash Lab to purchase remote controller Water does not flow / Valve can be heard to open...
Sensor taps 2 years’ parts & labour If a defect is found in normal use, The Splash Lab will, at their discretion, repair, provide a replacement part or product, or make appropriate adjustments. Damage caused by accident, misuse, or abuse is not covered by this warranty. Improper care and cleaning will void the warranty.