Wiring Diagram - Desa VT36ENA Series Owner's Operation And Installation Manual

Direct-vent fireplace ng/lp “tudor” model
Hide thumbs Also See for VT36ENA Series:
Table of Contents

Advertisement

FIREPLACE INSTALLATION
24
Wall Switch Installation
Optional Remote Control Installation (Model WRC)

WIRING DIAGRAM

FIREPLACE INSTALLATION
Continued
WALL SWITCH INSTALLATION
The installation of a wall switch allows you to activate the gas control
valve and turn the fireplace on and off. The wall switch is to be
connected to the incoming 120 volt regular household wiring that
supplies the electricity to the fireplace. Refer to wiring diagram below.
OPTIONAL REMOTE CONTROL
INSTALLATION (Model WRC)
Note: If using optional wireless hand-held remote control, the wall
switch must be in the ON position to be operational. The remote control
then becomes the switching mechanism for fireplace operation.
1. Open lower louver panel of firebox.
2. The WRC model receiver does not require a battery. The re-
ceiver can be installed by first plugging the short extension
cord into the fireplace receptacle. Then plug the receiver unit
into the extension cord. Finally plug the ignition module plug
into the receiver unit (see Figure 46).
3. Activate the remote handset battery by removing the insulat-
ing tab on the back of the handset (see Figure 47). The battery
is included pre-installed.
4. Once the battery is activated the unit is ready to use.
5. Close lower louver panel.
WIRING DIAGRAM
INCOMING MAIN
GAS SUPPLY
EV1
EV2
GAS LINE TO
BURNER
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Pilot Burner
Pilot Gas
Line
24V AC
STEP DOWN
TRANSFORMER
120V AC
Fireplace
Receptacle
Extension Cord
Figure 46 - Installing the WRC Remote Receiver
Battery Cover
12 Volt Battery
Back of
Handset
Figure 47 - Installing Battery into Back of Handset
WALL SWITCH
(SUPPLIED)
BLACK
WHITE
GREEN
ELECTRICAL RATING:
120v, 60Hz, 0.7A
OPTIONAL
REMOTE
CONTROL
Remote Control
Receiver
Ignition
Module Plug
Pull to Remove
Insulation Tab
INCOMING
120V AC
(FUSE BOX
OR BREAKER)
111251-01B

Advertisement

Table of Contents
loading

This manual is also suitable for:

T36ena seriesT36epa series

Table of Contents