Page 1
OperatiOn and parts Manual GlOBuG series MOdels: GBW (pentapod With lamp) Serial No. G2400001 aNd above GBs (Offset pole With lamp) Serial No. G2500001 aNd above GBp (lamp Only) Serial No. G2600001 aNd above GBHM (Hitch Mount accessory) GBMp (Mounting plate)
Page 2
notes page 2 — globug lighting system • operation and parts manual — rev. #0 (06/24/13)
Page 3
globug lighting system • operation and parts manual — rev. #0 (06/24/13) — page 3...
fuel chemical warning Gasoline engine exhaust and some of its constituents are known to cause cancer, birth defects and other reproductive harm. page 4 — globug lighting system • operation and parts manual — rev. #0 (06/24/13)
, 2006 order via internet (dealers only) best deal! If you have an MQ Account, to obtain a Username Order parts on-line using Multiquip’s SmartEquip website! and Password, E-mail us at: parts@multiquip. com. I View Parts Diagrams I Order Parts To obtain an MQ Account, contact your District Sales Manager for more information.
safety information Do not operate or service the equipment before reading Potential hazards associated with the operation of this the entire manual. Safety precautions should be followed equipment will be referenced with hazard symbols which at all times when operating this equipment. may appear throughout this manual in conjunction with Failure to read and understand the safety safety messages.
Page 8
never use accessories or attachments that are not never operate this equipment when not recommended by Multiquip for this equipment. Damage feeling well due to fatigue, illness or when to the equipment and/or injury to user may result.
Page 9
safety information lighting system saFety lamp saFety Warning Warning never disconnect any emergency or safety devices. never attempt to replace lamp with the power on. These devices are intended for operator safety. Always unplug the power cord from the generator or Disconnection of these devices can cause severe injury, power source when changing the lamp.
Page 10
safety information balloon saFety eleCtriCal saFety Warning danger To prevent serious burns, never touch Lighting system is equipped with a ground pin on the power plug. For your protection, ALWAYS complete the or unzip the balloon envelope when the lamp is on.
Page 11
safety information loading and unloading Cart type - no lifiting hook Cart type - With lifiting hook If lighting system is not equipped with a transport lifting hook and the mast is removable, refer to the following If lighting system is equipped with a transport lifting hook, safety information.
sPecifications table 1. specifications Model GBW/GBS/GBP Input Voltage 90-130, 170-240 VAC Max. Current 9.3 A @ 120 V Frequency 50-60 Hz Single-Phase Appropriate Generator 1200 Watts lamp Lamp Type 1,000 Watt Metal Halide Total Luminous Flux 99,750 lm Standard Balloon Diameter 47.2 in (1200 mm) Light Coverage (360°) 150 ft (45.7 meters)
The Multiquip GloBug GBW, GBS, GBP are general- The GBW has a three-stage mast that extends to a height purpose, portable, glare-free lighting systems intended of up to 13 feet and 2 inches. The GBW has five outriggers for emergency and remote lighting needs.
comPonents GBW/GBWE GBWE*/GBHM/ GBHM GBMP GBMP ONLY Extension pole for GBWE is 35 inches long, aluminum. Figure 5. GBW/GBS/GBP Components page 18 — globug lighting system • operation and parts manual — rev. #0 (06/24/13)
Page 19
comPonents Figure 5 shows the location of the controls and components 14. lamp/balloon bolt — Used to tighten mast when for the GBW Lighting System. The functions of each control attached to the lamp/balloon assembly. is described below: 15. Fan motor (blower) — Inflates the balloon as soon 1.
setuP GBW Setup upper or lower position. Placing the lock in the upper position will provide 1 foot (305 mm) more height. See 1. Set the GBW on a firm level surface where there is Figure 8. enough space around the pentapod for the outriggers to be deployed.
Page 21
setuP GBS Setup 4. Attach the straight pole to the clamps. Tighten locknuts on both clamps. See Figure 13. 1. Attach one of the clamps that come with the GBS to the external support pole. The clamps may be attached to STRAIGHT POLE vertical, horizontal, or angled pole.
Page 22
setuP balloon installation (gbW/gbs) 4. Secure the power cable by hooking it to the eyelet on the bottom of the balloon as shown in Figure 18. 1. Insert the balloon assembly into the mast. Tighten the T-bolt securely. See Figure 15. CABLE HOOK BALLOON PROTECTIVE...
Page 23
setuP GBHM iNStALLAtiON The GBHM Hitch Mount can be used to attach a balloon/ lamp assembly (GBP) to the hitch of a truck or similar vehicle. See Figure 20 for installation procedure. LOCKING BOLT BALL INSTALL HITCH COTTER REMOVE BOLT OR LOCKING COTTER PIN GBHM...
Page 24
setuP GBMp iNStALLAtiON The GBMP Plate Mount is attached to a trailer or similar vehicle to support the balloon/lamp assembly (GBP). See Figure 21 for installation procedure. T-HANDLE TURN CLOCKWISE TO LOCK POLE CONNECT TO POWER SOURCE POLE INSERT BOLT AND TIGHTEN NUT TO LOCK TRAILER FRAME...
oPeration raising the mast (gbW) loWering the mast (gbW) 1. Loosen the T-bolt holding the second mast and push danger mast all the way down. Tighten T-bolt securely. See ALWAYS make sure the area above Figure 24. the lighting system is open and clear of overhead power lines and other SECOND MAST...
Page 26
oPeration applying poWer NOTICE 1. Before applying power, make sure that the Power If the power cable is accidentally unplugged from on/oFF switch (Figure 26) is in the oFF position. the power source, wait three to five minutes before reconnecting the power. This will allow time for the fan to reset and ensure balloon will inflate properly when POWER power is reconnected.
Page 27
oPeration 4. To turn off the lamp, press and hold the dimmer switch 7. Continue pulling upward on the mast until all the for 3 seconds. The LED will light red and the lamp will pentapod legs are fully retracted and are stowed. See turn off.
maintenance replaCing lamp 3. Remove the lamp guard. 4. Press the tabs on the lamp holder and push up lamp danger holder to release it from lamp. See Figure 37. Never attempt to replace lamp in a wet place. The possibility exists of electric shock.
Page 29
maintenance 3. Slide in the new replacement balloon over the top of NOTICE the lamp guard assembly. See Figure 42. Do not use excessive force when screwing the lamp to prevent lamp from breaking. 7. Secure lamp holder on top of the lamp. 8.
Page 30
maintenance Filter replaCement 3. Turn the three locking tabs outwards to release the air plate. See Figure 44. 1. Remove the balloon as described in the STORAGE 4. Remove the air plate and filter. See Figure 45. section. 2. Turn the balloon/lamp assembly upsidedown to access AIR PLATE the filter.
Page 31
maintenance table 6. troubleshooting SYMptOM possible problem SOLutiON Is plug disconnected? Plug in correctly. Is generator power switched off? Turn on switch. Is lamp loose? Screw lamp securely into socket. Is power connector disconnected or Connect disconnected connector. loose? Are any other electric appliances Lamp does not light.
Page 32
maintenance GBW/GBWE Figure 47. Maintenance Check Points page 32 — globug lighting system • operation and parts manual — rev. #0 (06/24/13)
Page 33
maintenance table 7. periodic Check and maintenance Figure part CHeCK iteM SOLutiON Lamp (Base) Lamp base loose? Screw in securely. • Lamp Holder Lamp holder loose? Replace. Lamp Pipe Frame Pipe Frame skewed Replace. & Lamp Defective lamp? Replace. • Balloon (Envelope) Defective or dirty? Replace.
wiring Diagram WHITE WHITE WHITE WHITE WHITE WHITE BLACK BLACK BLACK BLACK BLACK(-) BLACK(-) RED(+) RED(+) BLACK BLACK WHITE WHITE Green/Yellow Green/Yellow WHITE WHITE BLACK BLACK RED(+) RED(+) BLACK(-) BLACK(-) WHITE WHITE BLACK BLACK Green/Yellow Green/Yellow page 34 — globug lighting system • operation and parts manual — rev. #0 (06/24/13)
Page 35
notes globug lighting system • operation and parts manual — rev. #0 (06/24/13) — page 35...
A blank entry generally indicates that the item is not sold assembly/kit that can be purchased, or is not available separately or is not sold by Multiquip. Other entries will for sale through Multiquip. be clarifi ed in the “Remarks” Column.
suggesteD sPare Parts gbW/gbs/gbp lighting system 1 to 3 units Qty. description 2....E000125600 ..LAMP 2....A300275900 ..E BALLAST ASSY 2....A100057000 ..BALLOON CLOTH CP 3....A300155100 ..FILTER 1....1654000230 ..BALLOON PATCH KIT NOTICE Part numbers on this Suggested Spare Parts list may supersede/replace the part numbers shown in the following parts lists.
namePlates anD Decals (gbw) MODEL SERIAL NO. page 38 — globug lighting system • operation and parts manual — rev. #0 (06/24/13)
Page 39
namePlates anD Decals (gbw) part no. part name Qty. remarKs A400324800 DECAL; GLOBUG INFORMATION A400166701 DECAL; LATCH, RIGHT A400324100 DECAL; LATCH, LEFT A400290900 DECAL; CAUTION, LAMP INFORMATION (ENGLISH) A400324200 DECAL; CAUTION, LAMP INFORMATION (FRENCH) A400326400 DECAL; LAMP TYPE A400325000 DECAL; CAUTION, AC ONLY A400206500 DECAL;...
namePlates anD Decals (gbs) MODEL SERIAL NO. page 40 — globug lighting system • operation and parts manual — rev. #0 (06/24/13)
Page 41
namePlates anD Decals (gbs) part no. part name Qty. remarKs A400193300 DECAL; GLOBUG LIGHTING SYSTEM A400323800 DECAL; GLOBUG INFO, ELECTRIC SHOCK(FRENCH) A400204701 DECAL; GLOBUG INFO, ELECTRIC SHOCK(ENGLISH) A400326400 DECAL; LAMP TYPE A400290900 DECAL; CAUTION, LAMP INFORMATION (ENGLISH) A400324200 DECAL; CAUTION, LAMP INFORMATION (FRENCH) A400325000 DECAL;...
Pole assy (gbs) page 50 — globug lighting system • operation and parts manual — rev. #0 (06/24/13)
Page 51
Pole assy (gbs) part no. part name Qty. remarKs A200056702 OFFSET POLE A300166600 POLE E000077100 KNOB E000093400 CLAMP 0013112040 BOLT, M12x40 0033112000 NUT, M12 A000028100 POLE MOUNT KIT ..........1....INCLUDES ITEMS W/ # CONTACT MQ UNIT SALES globug lighting system • operation and parts manual — rev. #0 (06/24/13) — page 51...
hitch mount assy (gbhm) page 52 — globug lighting system • operation and parts manual — rev. #0 (06/24/13)
Page 53
hitch mount assy (gbhm) part no. part name Qty. remarKs A300164601 SHAFT, JOINT A300164501 JOINT A300166600 POLE 0033112000 NUT, M12 0013112040 BOLT, M12x40 GBHM HITCH MOUNT ..........1....INCLUDES ITEMS W# CONTACT MQ UNIT SALES globug lighting system • operation and parts manual — rev. #0 (06/24/13) — page 53...
Need help?
Do you have a question about the GBW and is the answer not in the manual?
Questions and answers