Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Toshiba Manuals
Air Conditioner
RAV-RM801 CTP-TR
Service manual
Toshiba RAV-RM801 CTP-TR Service Manual
Split type
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
page
of
105
Go
/
105
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Table of Contents
Construction Views (External Views)
Rav-Rm401Ctp*, Rm561Ctp
Rav-Rm801Ctp
Systematic Refrigerating Cycle Diagram
Wiring Diagram
Specifications of Electrical Parts
Indoor Control Circuit
Indoor Controller Block Diagram
Control Specifications
Indoor Print Circuit Board
Troubleshooting
Summary of Troubleshooting
Troubleshooting
Replacement of Service P.C. Board
Setup at Local Site and Others
Indoor Unit
Setup at Local Site / Others
How to Set up Central Control Address Number
Address Setup
Address Setup & Group Control
Address Setup (Manual Setting from Remote Controller)
Confirmation of Indoor Unit No. Position
Detachments
Exploded Views and Parts List
Rav-Rm401Ctp-E, Rav-Rm401Ctp-Tr Rav-Rm561Ctp-E, Rav-Rm561Ctp-Tr
Rav-Rm801Ctp-E, Rav-Rm801Ctp-Tr
Rav-Rm1101Ctp-E, Rav-Rm1101Ctp-Tr Rav-Rm1401Ctp-E, Rav-Rm1401Ctp-Tr
Advertisement
Quick Links
1
Table of Contents
2
Control Specifications
Download this manual
FILE NO. SVM-18038-1
SERVICE MANUAL
AIR-CONDITIONER
(SPLIT TYPE)
INDOOR UNIT
<Ceiling type>
RAV-RM401CTP Series
RAV-RM561CTP Series
RAV-RM801CTP Series
RAV-RM1101CTP Series
RAV-RM1401CTP Series
RAV-RM1601CTP Series
R32 or R410A
Revised on March, 2019
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Troubleshooting
TROUBLESHOOTING
39
Troubleshooting
41
Need help?
Do you have a question about the RAV-RM801 CTP-TR and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Toshiba RAV-RM801 CTP-TR
Air Conditioner Toshiba RAV-GM 801UT-E Service Manual
Split type, outdoor unit (125 pages)
Air Conditioner Toshiba RAV-RM561FT-EN Service Manual
Air-conditioner (split type) (111 pages)
Air Conditioner Toshiba RAV-RM561FT-EN Installation Manual
Indoor unit (28 pages)
Air Conditioner Toshiba RAV-RM561FT-EN Owner's Manual
(68 pages)
Air Conditioner Toshiba RAV-RM401CTP Series Service Manual
(105 pages)
Air Conditioner Toshiba RAV-RM401CTP-E Installation Manual
(28 pages)
Air Conditioner Toshiba RAV-RM561CTP-E Owner's Manual
Split type indoor unit (18 pages)
Air Conditioner Toshiba RAV-RM801KRTP Series Service Manual
High wall type (113 pages)
Air Conditioner Toshiba RAV-RM301KRTP Series Service Manual
High wall type (113 pages)
Air Conditioner Toshiba RAV-RM561KRTP-E Installation Manual
(56 pages)
Air Conditioner Toshiba RAV-RM561BTP Series Service Manual
Concealed duct type (97 pages)
Air Conditioner Toshiba RAV-RM801UTP Series Service Manual
(106 pages)
Air Conditioner Toshiba RAV-RM801UTP-E Service Manual
(106 pages)
Air Conditioner Toshiba RAV-RM561UTP Series Service Manual
(106 pages)
Air Conditioner Toshiba RAV-RM801 CTP-E Service Manual
Split type (105 pages)
Air Conditioner Toshiba RAV-RM301KRTP-NZ Owner's Manual
Wireless remote controller (44 pages)
Summarization of Contents
SAFETY CAUTION
Definition of Qualified Installer or Qualified Service Person
Defines the qualifications and knowledge required for installation and service personnel.
Definition of Protective Gear
Details the protective gear required for various types of work related to the air conditioner.
MEANING OF SYMBOLS DISPLAYED ON THE UNIT
Explains the meaning of symbols used on the unit for safety and operation.
Warning Indications on the Air Conditioner Unit
Lists and explains warning labels found on the main unit.
Precaution for Safety
Declaration of Conformity
Specifications
Refrigerant (R32 or R410A)
Safety Caution Concerned to Refrigerant R32 or R410A
Highlights safety precautions and differences related to R32 or R410A refrigerant.
Cautions on Installation/Service
Provides specific cautions for installation and service involving R32 or R410A refrigerant.
Pipe Materials
Details the types of pipes recommended for refrigerant lines, including copper pipe specifications.
Tools
CONSTRUCTION VIEWS (EXTERNAL VIEWS)
Indoor Unit
Provides external views and dimensions for indoor units RAV-RM401CTP* and RAV-RM561CTP*.
SYSTEMATIC REFRIGERATING CYCLE DIAGRAM
Indoor Unit
Illustrates the refrigerating cycle for single, twin, and triple type indoor unit combinations.
WIRING DIAGRAM
Indoor Unit
Shows the wiring diagram for the indoor unit, including connections and components.
SPECIFICATIONS OF ELECTRICAL PARTS
Indoor Unit
Lists specifications for various electrical parts used in the indoor unit.
INDOOR CONTROL CIRCUIT
Indoor Controller Block Diagram
Illustrates the block diagram of the indoor controller and its connections to remote controllers.
Control Specifications
Details control specifications for operation modes, temperature settings, and fan speed selection.
Indoor Print Circuit Board
Shows an image and labels of the indoor unit's print circuit board components.
TROUBLESHOOTING
Summary of Troubleshooting
Provides an overview of troubleshooting procedures, required tools, and confirmation points before diagnosis.
Troubleshooting
Lists check codes, their causes of occurrence, and diagnostic procedures for indoor unit errors.
REPLACEMENT OF SERVICE P.C. BOARD
Indoort Unit
Details procedures for replacing the indoor unit's P.C. board, including data backup and restoration.
SETUP AT LOCAL SITE AND OTHERS
Indoor Unit
Covers test run setup, forced defrost, LED displays, function selection, and remote controller wiring.
1:1 Model Connection Interface (TCC-LINK adapter)
Explains the function, block diagram, and wiring for the 1:1 model connection interface.
How to Set up Central Control Address Number
Guides on setting the central control address number for indoor units via the remote controller.
ADDRESS SETUP
Address Setup
Details the process of setting line, indoor, and group addresses, including manual and automatic methods.
Address Setup & Group Control
Explains terminology, system configurations, and group control operations for indoor units.
Address Setup (Manual Setting from Remote Controller)
Provides a step-by-step guide for manually setting addresses using the remote controller.
Confirmation of Indoor Unit No. Position
Describes how to check and confirm indoor unit addresses and positions via the remote controller.
Maintenance/Check list
DETACHMENTS
Ceiling Type
Details the detachment and attachment procedures for specific parts of the ceiling type indoor unit.
EXPLODED VIEWS AND PARTS LIST
RAV-RM401CTP-E, RAV-RM401CTP-TR, RAV-RM561CTP-E, RAV-RM561CTP-TR
Provides exploded views and parts lists for specific RAV-RM401/561CTP models.
RAV-RM801CTP-E, RAV-RM801CTP-TR
Provides exploded views and parts lists for RAV-RM801CTP models.
RAV-RM1101CTP-E, RAV-RM1401CTP-E, RAV-RM1601CTP-E RAV-RM1101CTP-TR, RAV-RM1401CTP-TR, RAV-RM1601CTP-TR
Provides exploded views and parts lists for RAV-RM1101/1401/1601CTP models.
WARNINGS ON REFRIGERANT LEAKAGE
Check of Concentration Limit
Details refrigerant concentration limits and requirements for installation rooms to ensure safety.
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the RAV-RM801 CTP-TR and is the answer not in the manual?
Questions and answers