Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Ultima Manuals
Dental equipment
HT18/36
Installation & user manual
Ultima HT18/36 Installation & User Manual
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
page
of
52
Go
/
52
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
Abbrevia Ons
Specifica Ons
Tritek Controller
Operator Parts Iden Fica on
Site Layout
Gate Pull & Running Forces
Cable Recommenda Ons
Anchoring the Founda on Plate
Removing the Lid
Placing the Operator in Manual Override
Securing Operator to the Founda on Plate
Placing Oil in the Gearbox
Moun Ng the Marker Magnet
Tritek Control Board Layout
Overview of Low Power Inputs & Outputs
Charging Supply Op Ons
Menu Naviga on Overview
Commissioning the Operator for the First Me
Two Sets of Safety Beams (Relay Output)
External Radio Receiver & Loop Detector
Closing Safety Beam (FET Output & Relay Output)
Opening Safety Beam (FET Output & Relay Output)
Connec Ng Common External Devices
Connec on for Relay Module
Electric & Magne C Locks
Two Synchronised Operators Connected to One Set of Safety Beams
Control Board Func Ons
Beam Se Ngs
Auto Close Setup
Remote Se Ngs
Pedestrian Entry
Light Se Ngs
Security Se Ngs
Lock Se Ngs
Opera Ng Modes
GSM Se Ngs
Energy Saving
USB Se Ngs
HID Se Ngs
Diagnos Cs
General Se Ngs
Time Manager
Gate Setup
Holiday Lockout
Ground Loop
Upgrading Controller so Ware
Service Schedule
Warning Messages
Glossary
Technical Specifica Ons
Terms & Condi Ons
Warranty & Disclaimer
Advertisement
Quick Links
Download this manual
RT25/50
Regular Traffic
12V/24V
•
25/50m per min
•
500/300kg
•
Ver 1.01
•
Proudly manufactured by
www.dace.co.za
HT18/36
High Traffic
12V/24V
•
18/36m per min
600/300kg
•
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the HT18/36 and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Ultima HT18/36
Dental equipment Ultima 250 Series Owner's Manual
(20 pages)
Dental equipment Ultima RT25/50 Installation & User Manual
(52 pages)
Summarization of Contents
ABBREVIATIONS
INTRODUCTION & RECOMMENDATIONS
Gate Installation Prerequisites
Checks to ensure the gate is suitable for automation and safe operation.
Electrical Safety Precautions
Warnings and requirements for safe electrical connections and installations.
ULTIMA TECHNICAL SPECIFICATIONS
Gate Specifications
Details on maximum gate mass, pull, running forces, and size.
Motor Specifications
Information on supply voltage, current draw, standby power, and receiver details.
TRITEK CONTROLLER SPECIFICATIONS
Controller System Details
Specifications for processor, memory, display, and user interface.
Inputs and Outputs
Lists available inputs and outputs for various functions and devices.
OPERATOR PARTS IDENTIFICATION
GATE PULL & RUNNING FORCES
GATES ON A GRADIENT
CABLE RECOMMENDATIONS
ANCHORING THE FOUNDATION PLATE
PLACING THE OPERATOR IN MANUAL OVERRIDE
SECURE OPERATOR TO THE FOUNDATION PLATE
MOUNTING THE RACK ON THE GATE
PLACING OIL IN THE GEARBOX
MOUNTING THE MARKER MAGNET
TRITEK CONTROL BOARD LAYOUT
OVERVIEW OF POWER CONNECTIONS & FUSES
OVERVIEW OF LOW POWER INPUTS & OUTPUTS
CHARGING SUPPLY OPTIONS
MENU NAVIGATION OVERVIEW
Joystick Menu Navigation
Explanation of how to navigate the controller's menu using the joystick.
Quick Nav Screen Functionality
Overview of shortcuts to common functions via the Quick NAV screen.
COMMISSIONING THE OPERATOR FOR THE FIRST TIME
Step 1: Programming Gate Limits
Process for setting the open and closed positions using the Setup Wizard.
Step 2: Setting Collision Sensing
Configuration of safety features for detecting obstructions.
Step 3: Programming a Remote
Steps to add and configure remote control buttons for gate operation.
TWO SETS OF SAFETY BEAMS (RELAY OUTPUT)
EXTERNAL RADIO RECEIVER & LOOP DETECTOR
CLOSING SAFETY BEAM (FET OUTPUT)
CLOSING SAFETY BEAM (RELAY OUTPUT)
OPENING SAFETY BEAM (FET OUTPUT)
OPENING SAFETY BEAM (RELAY OUTPUT)
CONNECTING COMMON EXTERNAL DEVICES
CONNECTION FOR RELAY MODULE
ELECTRIC LOCK
MAGNETIC LOCK
CONNECTING VARIOUS DEVICES TO PULSE & ALARM OUTPUTS
TWO SYNCHRONISED OPERATORS CONNECTED TO ONE SET OF SAFETY BEAMS
CONTROL BOARD FUNCTIONS
BEAM SETTINGS
Configuration options for safety beams, including auto-close and reverse functions.
AUTO CLOSE SETUP
REMOTE SETTINGS
Add Remotes (No groups)
Procedure for programming new remotes to the controller without using groups.
Second Method: Duplicate Group Functions
Copying existing remote functions to a new remote.
Add Remotes (With groups)
Adding remotes to specific groups for organized access control.
Edit Group
Managing functions and access permissions for different user groups.
PEDESTRIAN ENTRY
Pedestrian Gap
Setting the distance for partial opening for pedestrian access.
Pre Open Delay
Delay before gate opens for pedestrian access, allowing warning signals.
SECURITY SETTINGS
Ambush Alarm
Configuring an alarm triggered by blocked safety beams in the open position.
Break In Alarm
Configuring an alarm triggered by blocked safety beams while the gate is closed.
LOCK SETTINGS
Off When Open
Function to disable magnetic locks when the gate is open to save power.
GSM SETTINGS
USB SETTINGS
TIME MANAGER
Set Time & Date
Setting the controller's current date and time for accurate scheduling.
Set Time Period
Creating time periods for scheduled activation or deactivation of functions.
GATE SETUP
Setup Wizard
Automatic programming of gate open and closed limits.
Safety Settings
Configuration of closing and opening forces and collision sensing.
GATE RUN PROFILE
Open Ramp Up
Adjusts acceleration distance before reaching maximum opening speed.
Opening Speed
Sets the maximum speed for gate opening.
HOLIDAY LOCKOUT
GROUND LOOP (Loop Detector)
UPGRADING CONTROLLER SOFTWARE
SERVICE SCHEDULE
WEEKLY Checks
Routine cleaning and checks to maintain the gate operator.
MONTHLY Checks
Monthly inspection of operator condition, parts, and forces.
NOTIFICATION MESSAGES
WARNING MESSAGES
GLOSSARY
TECHNICAL SPECIFICATIONS
CONTROLLER SYSTEM
Detailed specifications of the controller's hardware and software components.
SUPPLY SYSTEM
Specifications for power supply inputs, voltage, and battery charging.
TERMS & CONDITIONS
NOTES
WARRANTY
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the HT18/36 and is the answer not in the manual?
Questions and answers