Munro LP200B Owner's Manual

Munro LP200B Owner's Manual

Centrifugal pumps

Advertisement

LP Manual/Rev 0817
© 2017 MUNRO COMPANIES INC, ALL RIGHTS RESERVED

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LP200B and is the answer not in the manual?

Questions and answers

Summary of Contents for Munro LP200B

  • Page 1 LP Manual/Rev 0817 © 2017 MUNRO COMPANIES INC, ALL RIGHTS RESERVED...
  • Page 2 CAN cause serious ROTATION personal injury, death or major property damage if ignored. 1. All Munro pumps run in a Counter-Clockwise (CCW) rotation warns about hazards that WILL or CAN cause only. (When facing the pump’s suction tapping, all Munro minor personal injury, or property damage if ignored.
  • Page 3: Pipe Connection

    5. Replace and bolt the pump body to the motor assembly. 1. Drain the entire system if there is a danger of freezing. Call Munro technical support for any questions relating to 2. Drain valves are provided in both upper and lower pump start-up or operation of this pump.
  • Page 4: Pump Performance

    PUMP PERFORMANCE LP Series 3/4 HP - 3 HP Capacity - U.S. Gallons per Minute Shut Off Suction Discharge Max ▲ Discharge Pressure (PSI) at 5’ Suction Lift Pressure Pipe Pipe Suction Lift 2” 1-1/2” 15 Ft. 2” 1-1/2” 15 Ft.
  • Page 5: Pump Specifications

    PUMP SPECIFICATIONS LP Series 3/4 HP - 3 HP Service Factor Motor Amps Motor Voltage Type Volts/Amps (Factory) Liquid Single Phase Three Phase Connected Temperature 115V 208V 230V 208V 230V 460V 11.6 16.6 115/208-230 Single 1-1/2 3450 230V 12.5 11.5 180˚F...
  • Page 6: Pump Dimensions

    PUMP DIMENSIONS LP Series 3/4 HP - 3 HP Discharge Suction 1 1/2” 2” 19 3/4” 3 5/8” 4 1/4” 8 1/2” 7 1/2” 9 1/2” 10 7/8” 9 1/2” 2 3/8” 4 3/4” 2 5/8” 5 1/4” 6” 1 1/2”...
  • Page 7: Parts Breakdown

    PARTS BREAKDOWN LP Series 3/4 HP - 3 HP ITEM SINGLE HORSEPOWER 1 1/2 PHASE MODEL NO. LP075B LP100B LP150B LP200B LP300B DESCRIPTION PART NO. Motor, Nema J - 1 Phase MLP119370 MLP119399 MLP119219 MLP26452 MLP26453 Motor Access Cover Screw, Access Cover ▲...
  • Page 8: Terms And Conditions

    12 months or 1000 hours of operation which prevents normal function and The Company deems that the breakdown or fail- ure is a result of defects in manufacturing or workmanship, Munro will repair the breakdown or failure or replace any defective part or the whole unit at the Company’s discretion. Freight charges will be the User’s responsibility.
  • Page 9 Pump leaks at shaft 1. Worn mechanical shaft seal 1. Replace rotary seal (See Rotary Seal Replacement) Call Munro technical support for any questions relating to start-up or Download troubleshooting guide @ www.munrocompanies.com operation of this pump. Toll Free: 1.800.942.4270 Page 8...