5. Wait five (5) minutes to clear out any gas.
If you then smell gas, STOP! Follow "B" in
the safety information in column 1. If you
don't smell gas, go on the next step.
6. Press in and turn control knob counter-
clockwise
Press in control knob for five (5) seconds
(see Figure 12).
7. With control knob pressed in, press and release
ignitor button. This will light pilot. If needed,
keep pressing ignitor button until pilot lights.
Note: If pilot does not stay lit, contact a
qualified service person or gas supplier for
repairs.
8. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob.
• If control knob does not pop out when
released, contact a qualified service person
or gas supplier for repairs.
Note: If pilot goes out, repeat steps 4
through 8.
9. Slightly push in and turn control knob coun-
terclockwise
10. Wait one minute and move switch to the
ON position to light burner. Note: AUTO is
only functional when using optional remote
control accessory.
11. Set flame adjustment knob to any level
between HI and LO.
Figure 12 - Setting Control Knobs
www.desatech.com
to the PILOT position.
to the ON position.
114926-01B