Desa Firewerks VTDMV18NA Owner's Operation And Installation Manual page 6

Vented decorative gas log heater
Table of Contents

Advertisement

CHECK GAS TYPE
Use the correct gas type (natural or propane/LP) for
your unit. If your gas supply is not correct, do not
instal in fireplace. Call dealer where you bought
the appliance for proper type of appliance.
WARNING: This appliance
is equipped for (natural or pro-
pane/LP) gas. Field conversion
is not permitted.
INSTALLATION AND CLEARANCES
Figure 2 shows technical information regarding
the installation of your gas log set. Please make
sure all specifications shown are applicable before
installation is attempted.
LOG SIZING REQUIREMENTS
MINIMUM FIREBOX SIZE
LOG
SIZE HEIGHT DEPTH WIDTH WIDTH
18"
20"
14"
24"
20"
14"
*Measured at 14" depth
6
FRONT REAR* MIN. FLUE
SIZE
25"
20.5"
6.5"
29"
24.5"
6.5"
www.desatech.com
Damper
Clamp
Damper
Clamp
Damper
Masonry
Fireplace
Figure 4 - Attaching Damper Clamp
Damper
Damper
Manufactured
Fireplace
114926-01B