Download Print this page
August AT-30 Manual

August AT-30 Manual

Wastewater treatment plants

Advertisement

Quick Links

WASTEWATER TREATMENT
P L A N T T E C H N I C A L PA S S
AT SYSTEM
S O LU T I O N S F O R H U M A N A N D N AT U R E
WASTEWATER TREATMENT
PLANT MODEL AT6 - AT50

Advertisement

loading
Need help?

Need help?

Do you have a question about the AT-30 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Performance and Physical Properties of the Unit
Performance of the Unit
Details the daily load of organic pollutants and hydraulic load of the unit.
Rules for the Installation of the Unit
Selection of Installation Location
Guidelines for choosing the optimal site for the wastewater treatment unit.
Preparation for Construction
Covers requirements for wastewater pipes, depth, and pit dimensions.
Unit Construction Guidelines
Earthwork and Pit Excavation
Details the two-step process for excavating the pit for the unit.
Unit Installation Base and Burial
Discusses the need for a concrete base and options for unit burial.
Groundwater Considerations
Addresses challenges and solutions for sites with high groundwater levels.
Mechanical and Electrical Devices Overview
Solids Bag Functionality
Explains the function of the solids bag for separating gross solids from wastewater.
Air Distribution Panel and Valves
Details the air distribution manifold and its adjustable valves for controlling aeration.
AUGUST BASIC Controller Operation Guide
Initial Setup (First Run)
Covers language selection, date, and time setting for the controller.
Changing Operating Mode and Programs
Explains how to navigate the menu to select different operational programs.
Available Controller Programs
Lists and briefly describes the standard and non-standard programs for the controller.
Operation and Maintenance Instructions
Maintenance Schedule and Tasks
Outlines periodic maintenance checks and specific tasks for unit upkeep.
Operational Phenomena and Control
Addresses common operational issues like foam, odour, and blower control.
Controller Alarms and Error Messages
Explains the controller's alarm system, including optical signals and their meanings.
Removal of Excess Sludge
Measurement of Settled Sludge Content
Explains the procedure for determining the amount of settled sludge using a test flask.