Safety Instructions
General Safety Instructions
Read and understand instructions before use. Use only for specified purpose. Modifications require authorization.
Compressed Air Supply System
Installation
Ensure clean, dry, lubricated air at correct pressure. Connect pipes with compatible dimensions.
Air Pressure
Maintain pressure between 5.5 and 6.5 bar. Lower pressure loses power, higher pressure causes damage.
Air Quantity
Refer to table 1 for continuous operation. Intermittent use reduces consumption.
Pipes, Hoses, and Connections
Use oil-resistant pipes, correct diameter for length, and unobstructed connections.
Cleaning the Air
Use a filter as close to the motor as possible. Filter air from impurities. Empty filter daily.
Lubrication
Motors require lubrication. Use special oil. Automatic lubricators recommended. 3-5 mg/m³ oil content.
Motor Use and Speed Adjustment
Adjusting the Speed
Vary compressed air line pressure or use a choke system. Adjusting airflow modifies performance.