Page 1
ELECTRICAL WATER HEATERS BEHOLDERE TANKS 08:013-1703 Manual Smart Control models 60, 110 and 160 Type 206 ECO, 211 ECO and 216 ECO...
Page 2
Model 60, Smart Control Type 206 ECO METRO number: 112061003 Plumbing number: 345181360 Model 110, Smart Control Type 211 ECO METRO number: 112111003 Plumbing number: 345181560 Model 160, Smart Control Type 216 ECO METRO number: 112161003 Plumbing number 345181760 Type 206 ECO...
Contents Transport Position Diagram Plumbing installation Electrical installation User Guide Maintenance Troubleshooting Guarantee terms Declaration of compliance...
Transport Inspect the water heater for damage and missing parts immediately upon receipt. Report any damage or missing parts to the carrier immediately. All shipping is the responsibility of the recipient unless otherwise agreed.
Check that the wall can bear the weight of the tank when full of water. A stand and plate set with adjustable feet is available for models 60, 110 and 160, making it possible to install a water heater on a level, firm surface.
Diagram Model 60-110-160 Hot water outlet Cold water inlet Connector 3/4” with plug (e.g. for circulation) Holes in mounting plate CC measurements for mounting plate Seen from above Dimensioned diagram All dimensions are in mm. Volume Type no. Model (litres)
Using softened water in a METRO THERM tank 4. Overflow 3/4” Water softened using salt can be used in a METRO THERM hot water tank. However, we 5. Drain tap recommend removing the anode before the tank is used, to avoid degradation of the anode.
Page 8
Safety device The safety valve must be mounted on the cold water supply pipe close to the tank, and easily ac- cessible for service and testing. It must be impossible to shut-off the pipe connecting safety valve and tank and the overflow from the safety valve. Diameter min. 3/4” (20 mm.). The overflow outlet must be visible and run to a drain.
Electrical installation Remember! The water Electrical installation can only be performed by an authorised heater must be filled with electrical installer. water before connecting The water heater has splashproof IP24 encapsulation and must always be extra-protected in electricity. accordance with the LVD directive. The water heater is fitted with Smart Control, which includes a thermostat, a thermal fuse and a display for setting the different forms of control systems and temperature levels.
Page 10
BR (SILICONE) Smart Control with 350 mm sensor bulb. Mechanical thermal fuse 95°C +/– 7°C Thermal fuse, Mechanical Electronic thermostat 60°C to 75°C TYPE: 216 ECO Smart Control with 450 mm sensor bulb. Mechanical thermal fuse 95°C +/– 7°C Thermostat, Electronic Electronic thermostat 60°C to 75°C...
User Guide Read this manual carefully before installation and using the water heater. Safety regulations Installation, first activation and maintenance of this product can only be performed by an authorised plumber/electrician, who will be responsible for observance of the relevant standards and installation regulations.
Page 12
Start When switching on electricity for the water heater – at the mains switch – the Smart Control will run a short test, during which the seven diodes will light in turn. After a few seconds, ECO mode will automatically cut in, using comfort level 2, meaning that the water heater is working. The diode opposite the comfort level in use will flash when the heating element is on.
Page 13
1 to 4, by pressing the level selector buttons + (arrow up), and – (arrow down), until the diode by the temperature level required comes on. Temperature level no. 1 = 60°C and should normally be used, as it minimises limescale ac- cumulation on the heating element, extending its service life.
Page 14
ECO + Holiday and Manual diodes, and the diodes for levels 1 to 4 will all be off. Pipes and fittings near the water heater can reach temperatures over 60˚C. The water heater is fitted with a thermal fuse that will cut-out in the event of overheating.
Maintenance External cleaning The tank can only be cleaned with a damp cloth. Window or glass cleaner can be used, but not scouring cream/powder or solvents. Always read the instructions on the cleaning product. Safety valve Always inspect the safety valve at least twice annually. The plumbing installer can show you how. When testing, water should flow out of the valve.
Page 16
Checking/replacing the anode Must be performed by an authorised plumbing/electrical installer. The tank is fitted with a magnesium anode that can be inspected. It is fitted in the bottom flange, and can be inspected by removing the connection to the tank and inserting a multimeter (see figure 9). If the anode current reading is greater than 0.3 mA, the mass of the anode is sufficient to protect the tank.
Troubleshooting The table below can help identify and remedy any problems. If a problem cannot be remedied using the table, contact an authorised plumbing/electrical installer. Fault Cause Action No water flow Water supply cut off (hot or Check ballcock is open. cold water pipe).
- The installer has stated manufacturing number when contacting METRO THERM. - The installer has sent a copy of the invoice for purchase or installation and the faulty product item to METRO THERM after replacement/repair. What the guarantee does NOT cover: - Compensation for anything other than the above, or for personal injury caused by any faults regarding the product.
Declaration of compliance The declaration of compliance is available on our website at: www.METROTHERM.dk...
Page 20
Get a 1-year extended guarantee on your METRO product We offer a one-year extended guarantee on your METRO product when you register the product, entering where and when it was installed and by which company. Go to http://FQR.dk or scan the QR code Enter product and installation details You will receive a mail confirming the extended guarantee.
Need help?
Do you have a question about the 211 ECO and is the answer not in the manual?