Maxwell BMOD0165 P048 B01 User Manual

Ultracapacitor energy storage modules

Advertisement

USER MANUAL
Maxwell Technologies
Ultracapacitor Energy Storage Modules
Models:
16 V Series:
 BMOD0500 P016 B01
 BMOD0500 P016 B02
 BMOD0250 P016 B01
 BMOD0110 P016 B01
Document 1008491
Please contact Maxwell Technologies directly for any technical specifications critical to application. All products featured on this
user manual are covered by the following U.S. patents and their respective foreign counterparts: 6643119, 7102877, 7180726
7203056, 7295423, 7342770, 7352558, 7384433, 7440258, 7492571, 7508651, 7580243, 7791860, 7791861, 7816891,
7859826, 7883553, 7935155, 7859826, 7883553, 7935155, 8072734, 8098481, 8279580 and patents pending.
MAXWELL TECHNOLOGIES, MAXWELL, MAXWELL CERTIFIED INTEGRATOR, ENABLING ENERGY'S FUTURE, BOOSTCAP, C
CELL, D CELL, CONDIS, RAD-PAK and their respective designs and/or logos are either trademarks or registered trademarks of
Maxwell Technologies, Inc. and may not be copied, imitated or used, in whole or in part, without the prior written permission
Maxwell Technologies, Inc. All contents copyright © 2014 Maxwell Technologies, Inc. All rights reserved. No portion of these
materials may be reproduced in any form, or by any means, without prior written permission from Maxwell Technologies, Inc.
®
48 V Series:
 BMOD0165 P048 B01
 BMOD0110 P048 B01
 BMOD0083 P048 B01
 BMOD0165 P048 B06
 BMOD0165 P048 B09
Downloaded From
Oneyac.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BMOD0165 P048 B01 and is the answer not in the manual?

Questions and answers

Summarization of Contents

2. Unpacking and Handling
2.1 Unpacking
Inspect shipping carton for damage, report issues, retain materials until inspected.
2.2 Handling
Follow handling precautions like not stacking or dropping modules to avoid damage.
3. Installation
3.1 Mechanical
Mount modules in any orientation, ensure co-planar mounting points for proper installation.
3.2 Electrical
Details electrical considerations including wiring, grounding, and terminal post connections.
3.2.1 Output Terminal Posts
Connect terminals with ring lugs or bus bars, ensuring proper thread depth and clean contacts.
3.2.2 Module to Module Connections
Modules use active voltage management; module-to-module balancing is not required.
3.2.3 Logic outputs
Provides overvoltage monitoring and temperature monitoring via open collector logic output.
3.3 Thermal Performance
Low internal resistance generates less heat; use natural or forced cooling for optimal performance.
5. Safety
5.1 Discharge Procedure
Procedure to discharge module safely using a voltmeter and resistor or shorting wire.
6. Maintenance
6.1 Routine Maintenance
Clean modules, check fasteners, inspect housing, and check connections periodically.

Table of Contents