Maxwell 16 V Series User Manual

Ultracapacitor energy storage modules

Advertisement

USER MANUAL
Maxwell Technologies
Ultracapacitor Energy Storage Modules
Models:
16 V Series:
 BMOD0500 P016 B01
 BMOD0500 P016 B02
 BMOD0250 P016 B01
 BMOD0110 P016 B01
Document 1008491
Please contact Maxwell Technologies directly for any technical specifications critical to application. All products featured on this
user manual are covered by the following U.S. patents and their respective foreign counterparts: 6643119, 7102877, 7180726
7203056, 7295423, 7342770, 7352558, 7384433, 7440258, 7492571, 7508651, 7580243, 7791860, 7791861, 7816891,
7859826, 7883553, 7935155, 7859826, 7883553, 7935155, 8072734, 8098481, 8279580 and patents pending.
MAXWELL TECHNOLOGIES, MAXWELL, MAXWELL CERTIFIED INTEGRATOR, ENABLING ENERGY'S FUTURE, BOOSTCAP, C
CELL, D CELL, CONDIS, RAD-PAK and their respective designs and/or logos are either trademarks or registered trademarks of
Maxwell Technologies, Inc. and may not be copied, imitated or used, in whole or in part, without the prior written permission
Maxwell Technologies, Inc. All contents copyright © 2014 Maxwell Technologies, Inc. All rights reserved. No portion of these
materials may be reproduced in any form, or by any means, without prior written permission from Maxwell Technologies, Inc.
®
48 V Series:
 BMOD0165 P048 B01
 BMOD0110 P048 B01
 BMOD0083 P048 B01
 BMOD0165 P048 B06
 BMOD0165 P048 B09
Downloaded From
Oneyac.com

Advertisement

Table of Contents
loading

Summary of Contents for Maxwell 16 V Series

  • Page 1 CELL, D CELL, CONDIS, RAD-PAK and their respective designs and/or logos are either trademarks or registered trademarks of Maxwell Technologies, Inc. and may not be copied, imitated or used, in whole or in part, without the prior written permission Maxwell Technologies, Inc. All contents copyright © 2014 Maxwell Technologies, Inc. All rights reserved. No portion of these materials may be reproduced in any form, or by any means, without prior written permission from Maxwell Technologies, Inc.
  • Page 2: Unpacking And Handling

    Material Authorization (RMA) number must be issued prior to returning the unit for repair or replacement. Handling Maxwell ultracapacitor modules are designed to provide years of trouble-free operation. Proper handling is required to avoid damage to module. In particular, the following handling precautions should be observed: ...
  • Page 3: Installation

    That pressure can be relieved through the vent tube. User Manual – 16 V and 48 V Modules – Doc. No. 1008491.13 © 2014 Maxwell Technologies, Inc. Page 2 Downloaded From...
  • Page 4 When tightening the terminal bolts, a torque of 20 N-m / 14.8 ft-lbs for the M8 and 30 N-m / 22.1 ft-lbs for the M10 bolts should be used. Do not exceed recommended torque. User Manual – 16 V and 48 V Modules – Doc. No. 1008491.13 © 2014 Maxwell Technologies, Inc. Page 3 Downloaded From...
  • Page 5 When several modules are connected in series for operating at higher voltage, care must be taken to ensure proper creepage and clearance distances in compliance with national safety standards for electrical equipment. User Manual – 16 V and 48 V Modules – Doc. No. 1008491.13 © 2014 Maxwell Technologies, Inc. Page 4 Downloaded From Oneyac.com...
  • Page 6 2. The Overvoltage Alarm will be asserted if any individual cell goes into an over voltage condition. The range of the alarm threshold is as follows: 2.73V minimum 2.80V nominal User Manual – 16 V and 48 V Modules – Doc. No. 1008491.13 © 2014 Maxwell Technologies, Inc. Page 5 Downloaded From Oneyac.com...
  • Page 7 The temperature rise can be expressed by the following equation. User Manual – 16 V and 48 V Modules – Doc. No. 1008491.13 © 2014 Maxwell Technologies, Inc. Page 6 Downloaded From Oneyac.com...
  • Page 8: Operation

    Prior to installation on or removal from the system, it is mandatory to fully discharge the module to guarantee the safety of all personnel. User Manual – 16 V and 48 V Modules – Doc. No. 1008491.13 © 2014 Maxwell Technologies, Inc. Page 7 Downloaded From...
  • Page 9: Maintenance

    (for example, the BK Precision DC Electronic Load Model 8500 or a similar tool). If the voltage is under 2V, connect the shorting wire provided by Maxwell to the + and – connectors.
  • Page 10: Specification

    Do not dispose of module in trash. Dispose of according to local regulations. 9. Specification Refer to datasheets at our website, www.maxwell.com, for specifications for each specific product. User Manual – 16 V and 48 V Modules – Doc. No. 1008491.13 ©...
  • Page 11 Maxwell Technologies, Inc. Maxwell Technologies SA Maxwell Technologies GmbH Maxwell Technologies Korea Co., Ltd. Maxwell Technologies Maxwell Technologies Global Headquarters Route de Montena 65 Leopoldstrasse 244 Room 1524, D-Cube City Shanghai Trading Co., Ltd. Shanghai Representative Office 3888 Calle Fortunada CH-1728 Rossens 80807 München...
  • Page 12 单击下面可查看定价,库存,交付和生命周期等信息 >>Maxwell Technologies(麦克斯威) Downloaded From Oneyac.com...

Table of Contents