Crestron iLux CLSI-C6W Operation Manual

Crestron iLux CLSI-C6W Operation Manual

Integrated lighting system

Advertisement

Crestron CLS/CLSI-C6 & CLS/CLSI-C6M
®
iLux
Integrated Lighting System
Operations Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iLux CLSI-C6W and is the answer not in the manual?

Questions and answers

Summarization of Contents

Features and Functions
Six Channel Dimming
Details the six channels of dimming for various lighting loads.
Six Group Shade Control
Describes control of motorized window treatments in six shade groups.
Energy Management
Covers energy saving via load shedding and occupancy sensing.
Versatile Front Panel Controls
Explains the functionality of the unit's front panel controls.
Built-in Motion Detector (CLS/CLSI-C6M)
Details the integrated infrared motion detector for automated control.
Daylight Harvesting
Describes energy saving by reducing light levels based on natural light.
IR Remote Control
Explains wireless remote control using an onboard IR receiver.
Multipoint Keypad Control
Details connecting up to 16 keypads for versatile control.
Touch Screen Support
Covers support for up to two touch screens without a central processor.
Multi-Unit Expansion
Explains system expansion by linking multiple CLS-C6 units.
Room Combining Support
Describes advanced features for combining rooms in complex layouts.
Specifications
Available Accessories
Lists optional accessories compatible with the CLS-C6.
Physical Description
CLS-C6M Overall Dimensions
Provides the physical dimensions of the CLS-C6M unit.
CLS-C6M Front Panel
Describes the components and layout of the front panel.
CLS-C6 Rear Panel
Describes the connectors and layout of the rear panel.
Setup
Network Wiring
Guidelines for wiring the Cresnet network for optimal performance.
Identity Code
Explains MNET ID assignment for network devices.
Installation
References detailed installation procedures for the system.
Configuring the CLS-C6
Configuring With Front Panel Controls
Describes basic setup using the unit's front panel controls.
Temporary Changes/Adjustments
How to make temporary adjustments to lighting or shade presets.
Changing Scene Presets
Procedure for modifying scene presets via the front panel.
Setup Mode
Mode for changing internal settings and scene presets.
Setup Mode Mnemonics
List of mnemonic codes used in Setup mode.
Scene Programming (Sc)
Setup option to adjust scene parameters and settings.
Setup Lighting Load Types (Ld)
Procedure to set the load types for each lighting load.
Setup Low-End Levels (LE)
Procedure to specify the low-end limit for lighting loads.
Setup High-End Levels (HE)
Procedure to set the full on level for lighting loads.
Setup Button Functions (bF)
Defines behavior of buttons on the unit and remote keypads.
Setup Up/Down Button Function (ud)
Defines the operation of the up/down button.
Setup Occupancy Sensing (oc)
Defines the operation of the Occupancy Sensing feature.
Run Auto-Discovery (Ad)
Finds network devices and assigns default functions.
Assign Shade Groups (AS)
Assigns shade controller channels to specific shade groups.
Display/Set MNET ID Of This Unit (id)
Changes the MNET ID for connecting to a Cresnet network.
Photocell Test (Ph)
Tests the photocell output.
Photocell Calibration (Pc)
Calibrates photocell response for daylight harvesting.
Photocell Lower Limit (PL)
Adjusts the lower limit for photocell dimming.
Photocell Response Time (Pr)
Adjusts the response time to photocell reading changes.
Restore Factory Defaults (Fd)
Resets all settings to their factory defaults.
Configuring with iLux Designer
Guides for configuring the CLS-C6 using iLux Designer software.
Load Schedule
Defines lighting loads, types, and wattage in iLux Designer.
Shades
Assigns shade controllers and defines shade groups in iLux Designer.
Scenes
Defines scene lighting levels and shade positions in iLux Designer.
CLS-C6
Configures CLS-C6 specific settings in iLux Designer.
Keypads
Adds and configures remote keypads in iLux Designer.
Touchpanel
Adds and configures touch screens in iLux Designer.
Finish
Sends project to CLS-C6 and sets network IDs in iLux Designer.
Console Command Settings
Settings adjustable via console commands.
IR Reception
Enables or disables IR reception using console commands.
LED Brightness
Sets brightness for white and green LEDs via console.
Glow Mode Brightness
Sets glow brightness for white LEDs via console commands.
Replacing the Function Button Label
Procedure for replacing the unit's button label.
Programming Software
Software Requirements for the PC
Lists minimum software versions required for programming.
Programming with SystemBuilder
Details using SystemBuilder for system programming.
Programming with D3 Pro
Details using D3 Pro software for lighting system control.
Programming with SIMPL Windows
Details using SIMPL Windows for control system programming.
Configuration Manager
View in SIMPL Windows for building control system hardware.
Program Manager
View in SIMPL Windows for assigning signals to symbols.
Uploading and Upgrading
Establishing Communication
Prerequisites for transferring programs or firmware.
Direct Serial
Method for direct serial communication with the CLS-C6.
Indirect
Method for indirect communication via a control system.
Programs and Firmware
Procedures for uploading programs and updating firmware.
Operation
Standard Mode
The default mode for recalling scenes and basic operations.
Button Types
Describes the different types of buttons on the CLS-C6.
Recall-Scene Buttons
Details function of buttons used to recall scenes.
Toggle-Scene Buttons
Explains how toggle scene buttons alternate actions.
Master (Last Scene) Raise/Lower Buttons
Describes master control for lighting loads in the last scene.
Lighting Master (Last Scene) Raise Buttons
Details master raise function for lighting loads in the last scene.
Lighting Master (Last Scene) Lower Buttons
Details master lower function for lighting loads in the last scene.
Shade Control (Open/Stop/Close/Stop) Buttons
Describes shade control functions for groups.
IR Receiver
How to use the IR receiver for functions.
Occupancy Sensing
Details the occupancy sensing feature and its actions.
Override Mode
Explains the override mode for controlling lights and shades.
Load Shedding (Demand Response)
Describes entering load shed mode for demand response.
Building Management System (BMS) Interface
Covers interface with Building Management Systems.
Problem Solving
Troubleshooting
Provides corrective actions for common trouble situations.
Check Network Wiring
Ensures optimum performance by using correct network wiring.
Calculate Power
Guidance on calculating wire gauge and power usage.
Appendix A: Supported Devices
Keypads
Lists default button functions for supported keypad types.
Shade Controllers
Lists supported shade controllers.
Touch Screens
Lists supported touch screens.
Joins
Digital Command Joins (from Touch Screen to CLS-C6)
Defines digital command joins for touch screen to CLS-C6 communication.
Digital Feedback Joins (from CLS-C6 to Touch Screen)
Defines digital feedback joins from CLS-C6 to touch screen.
Analog Command Joins
Defines analog command joins from touch screen to CLS-C6.
Analog Feedback Joins
Defines analog feedback joins from CLS-C6 to touch screen.
Bidirectional Serial Joins
Defines bidirectional serial joins between CLS-C6 and touch screen.
Appendix B: Console Commands
GREENLEDLEVEL
Displays or sets the green LED brightness level.
HELP
Displays a list of help categories.
INFO
Displays additional device information.
IR
Displays or enables/disables IR reception.
MOTIONSENSORLEVEL
Displays or changes the internal motion sensor sensitivity level.
PROJECTINFO
Displays project file name, date, and version.
PUTCONFIG
Loads the project file to the CLS-C6.
REBOOT
Reboots the CLS-C6.
REPORTCRESNET
Reports devices on the local network.
RESTORE
Sets all configuration parameters to factory default settings.
SYSTEM
Loads firmware to the CLS-C6.
UPLOAD
Loads firmware to a slave device on the local network.
VERSION
Displays the firmware version number.
WHITELEDLEVEL
Displays or sets the white LEDs brightness level.
WHITELEDGLOWLEVEL
Displays or sets the white LEDs glow brightness level.
Appendix C: RS-232 Commands
Command Format
Specifies the ASCII character set and packet format for commands.
Serial Command String Format to Third Party Controllers
Format for sending commands from a third-party controller.
Serial Command String Format From Third Party Controllers
Format for receiving commands from a third-party controller.
iLux Controller Code Table
Table mapping controller codes to descriptions.
RS-232 Command Table
Table listing RS-232 commands for controlling the iLux system.
Light Zone Commands
Light zone Level Command
Command to set light zone levels with optional fade time.
Light Zone Lower or Raise Command
Command to lower or raise light zone control.
Light Zone Stop Command
Command to stop light zone control.
Light Zone Toggle Command
Command to toggle light zone actions.
Light zone Lower Limit Command
Command to get light zone minimum limit.
Light Zone Upper Limit Command
Command to get light zone maximum limit.
Light Zone Load Type Command
Command to get light zone load types.
Light Zone Name Query Command
Command to read light zone names.
Shade Group Commands
Shade Group Position Command
Command to set shade group position.
Shade Group Position Query Command
Command to get shade group position.
Shade Group Open, Close and Stop Command
Command to open, close, or stop shade group(s).
Shade Group Jog Open and Close Command
Command to jog open or close shade group(s).
Shade Group Open/Stop/Close/Stop Command
Command to alternate between open, stop, and close shade functions.
Shade Group Name Query Command
Command to query shade group name.
Shade Type Query Command
Command to query shade type.
Scene Commands
Scene Recall
Command to recall a scene.
Scene Raise, Lower and Stop Command
Command to raise, lower, or stop scene light levels.
Scene Toggle Command
Command to toggle scene lights.
Scene Programming Commands
Scene Light Add/Remove Mask Command
Removes or adds light zones to scenes.
Scene Light Mask Status Command
Reads light mask status in scenes.
Scene Shade Mask Command
Removes or adds shade groups to scenes.
Scene Shade Status Command
Reads shade group mask status in scenes.
Scene Name Query Command
Queries scene name.
Room combining commands
Combine Rooms
Command to combine room controllers.
Un-Combine Rooms
Command to un-combine room controllers.
Query Combine Status
Command to query room combine status.
Override Commands
Override On Command
Command to turn on override.
Override Off Command
Command to turn off override.
Override Status Command
Reads the override status.
Load Shed Commands
Load Shed Mode
Enters load shed mode for demand response.
Load Shed On Command
Command to turn on load shed.
Load Shed Off Command
Command to turn off load shed.
Load Shed Status Command
Reads the load shed status.
Occupancy Operation Commands
Occupancy Commands
Sets or clears occupancy state.
Occupancy State Set/Clear Command
Sets or clears occupancy state.
Occupancy State Query Command
Queries occupancy state.
Photocell Operation Commands
Photocell Commands
Queries photocell active state.
Photocell Enable Command
Queries photocell active state.
Appendix E: Button Functions
Toggle Scene (on, 1-15)
Alternates between Recall Scene and Turn Off Scene Lights.
Raise Lighting Load (1-6)
Raises lighting load level while button is held.
Lower Lighting Load (1-6)
Lowers lighting load level while button is held.
Raise/Lower Lighting Load (1-6)
Raises or lowers lighting load level based on button press.
Master Raise Lighting Loads (Last Scene, All Lights, On scene, Scenes 1-15)
Master raise for dimmable lighting loads affected by scene.
Master Lower Lighting Loads (Last Scene, All Lights, On scene, Scenes 1-15)
Master lower for dimmable lighting loads affected by scene.
Master Raise/Lower Lighting Loads (Last Scene, All Lights, On scene, Scenes 1-15)
Master raise/lower for dimmable lighting loads affected by scene.
Toggle-Dim Scene (on, 1-15)
Toggles scene or enters cycle-dim mode.
Open Shades Full (All, Group 1-6)
Sends specified shades to full open position.
Close Shades Full (All, Group 1-6)
Sends specified shades to full closed position.
Stop Shades (All, Group 1-6)
Stops specified shades at current position.
Open Shades Momentary (All, Group 1-6)
Moves shades to open position while button is pressed.
Close Shades Momentary (All, Group 1-6)
Moves shades to closed position while button is pressed.
Open/Stop/Close/Stop (All, Group 1-6)
Alternates between open, stop, and close shade commands.
External Function (1-32)
Activates digital signals on the Cresnet system.
Dual External Function (1/2 ...31/32)
Activates dual digital signals on the Cresnet system.
Shift
Alternates between lower and upper functions for buttons.
Return and Warranty Policies
Merchandise Returns / Repair Service
Procedures for returning products for credit, exchange, or service.
Crestron Limited Warranty
Details Crestron's 3-year limited warranty for its products.

Table of Contents