Crestron iLux CLS-C6W Operation Manual

Crestron iLux CLS-C6W Operation Manual

Integrated lighting system

Advertisement

Crestron CLS/CLSI-C6 & CLS/CLSI-C6M
®
iLux
Integrated Lighting System
Operations Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iLux CLS-C6W and is the answer not in the manual?

Questions and answers

Summarization of Contents

Regulatory Compliance
FCC Compliance Statement
Federal Communications Commission (FCC) compliance information and cautionary notes.
IC Compliance Statement
Industry Canada (IC) compliance statement and requirements.
Features and Functions
Core Lighting and Shade Control
Highlights wall-mounted control, dimming, shade groups, and scenes.
Advanced Features and Controls
Six Channel Dimming
Details dimming capabilities for various load types up to 800W per channel.
Six Group Shade Control
Explains control of motorized window treatments in up to six groups.
Energy Management Features
Covers Crestron Green Light technology for energy efficiency.
Versatile Front Panel Controls
Describes front panel buttons, bar graphs, and display for intuitive control.
Extended System Capabilities
Built-in Motion Detector
Details the integrated motion detector for automated room occupancy control.
Daylight Harvesting Functionality
Explains energy savings through automatic light reduction based on natural light.
IR Remote and Keypad Control
Covers IR remote control and multipoint keypad connectivity.
Touch Screen and Multi-Unit Expansion
Details touch screen support and system expansion via linked units.
Room Combining Support
Describes advanced features for combining rooms and managing partitions.
System Integration and Specifications
Building Management System Integration
Discusses BMS integration capabilities for energy management.
Control System Integration
Details integration with Crestron 2-Series control systems and networks.
RS-232 Interface via C2N-IO
Explains RS-232 communication using the C2N-IO module for third-party control.
CLS-C6 Specifications Continued
Available Accessories List
Lists compatible accessories such as keypads, gateways, and expansion modules.
Physical Description
CLS-C6 Physical View
Illustrates the physical layout and components of the CLS-C6 unit.
Unit Dimensions and Panels
CLS-C6M Dimensions and Front/Rear Panels
Provides dimensional drawings and details panel layouts for CLS-C6M.
Connectors, Controls, and Indicators
Front Panel Interface Elements
Describes bar graphs, label strip, function buttons, IR detector, and display.
Front Panel Control Details
Mode, Navigation, and Power Controls
Explains mode buttons, navigation, ON/OFF, and load terminals.
Network and System Ports
Describes Cresnet network ports for system and local devices.
Setup Procedures
Network Wiring and Identity Code
Covers wiring best practices and setting MNET IDs for network devices.
Installation Guidance
Refers to installation guides for detailed setup instructions.
Configuring the CLS-C6
Front Panel Configuration and Scene Presets
Describes basic setup and modifying scene presets via the front panel.
Setup Mode Operations
Entering and Navigating Setup Mode
Explains how to enter Setup mode and navigate options, with notes on lockouts.
Setup Mode Mnemonics and Scene Programming
Setup Mode Mnemonics
Lists mnemonic codes for various setup options and their descriptions.
Scene Programming (Sc)
Allows adjustment of scene parameters, including those beyond scene 6.
Lighting Load Configuration
Setup Lighting Load Types (Ld)
Describes how to set the load types for each lighting load using the setup menu.
Lighting Level Settings
Setup Low-End Levels (LE)
Explains how to set low-end limits to avoid flickering at low light levels.
Button and Load Configuration
Setup High-End Levels (HE)
Details setting the 'full on' level for lighting loads below maximum brightness.
Setup Button Functions (bF)
Defines behavior of unit buttons and remote keypads, overriding defaults.
Button and Sensor Configuration
Setup Up/Down Button Function (ud)
Configures the up/down button for master light or shade control.
Setup Occupancy Sensing (oc)
Defines actions for the occupancy sensing feature based on room state.
Network Device Discovery
Run Auto-Discovery (Ad)
Finds network devices, assigns IDs, and sets default functions for new hardware.
Shade Group Assignment
Assign Shade Groups (AS)
Assigns shade controller channels to specific shade groups.
Unit Identification
Display/Set MNET ID Of This Unit (id)
Guides on changing the unit's MNET ID for Cresnet network connection.
Photocell Testing and Calibration
Photocell Test (Ph)
Used to test the output of the photocell and its real-time percentage.
Photocell Calibration (Pc)
Calibrates photocell response for lighting control based on daylight.
Photocell Adjustments
Photocell Lower Limit (PL)
Sets the minimum dim level for photocell control to prevent flickering.
Photocell Response Time and Defaults
Photocell Response Time (Pr)
Adjusts the time lights take to respond to photocell reading changes.
Restore Factory Defaults (Fd)
Resets all unit settings to their original factory defaults.
iLux Designer Configuration Sections
Load Schedule Configuration
Identifies loads, types, wattage, and dimmer levels for system setup.
Shade Configuration
Assigns shade controllers to groups and defines travel times.
Scene Configuration
Defines lighting levels and shade positions for up to 17 scenes.
CLS-C6 Configuration Options
CLS-C6 Specific Settings
Configures ramp rate, button functions, and motion sensor timeouts.
Keypad and Touchpanel Configuration
Adds and configures keypads and touch screens with custom actions.
Finish Screen and Console Commands
Sends projects, sets IDs, and manages console settings like IR and LEDs.
Front Panel Labeling and Console Command Details
IR Reception and LED Brightness Settings
Details console commands for IR reception and LED brightness adjustments.
Glow Mode Brightness and Button Label Replacement
Explains Glow mode and replacing front panel labels.
Programming Software and Requirements
PC Software Requirements
Lists minimum software versions needed for iLux Designer and related tools.
Programming Tools Overview
Overviews of SystemBuilder and D3 Pro for creating lighting and control programs.
SIMPL Windows Programming
Configuration Manager for SIMPL Windows
Guides on adding CLS-C6 to a system via the Device Library in SIMPL Windows.
Program Manager in SIMPL Windows
Program Manager Overview
Explains the Program Manager view for assigning signals to symbols in SIMPL Windows.
Uploading and Upgrading Procedures
Establishing Communication Methods
Details direct serial and indirect communication setup steps.
Programs and Firmware Management
SIMPL Windows Program Upload
Describes uploading programs to the control system using SIMPL Windows.
Firmware Upgrade Process
Outlines steps for upgrading CLS-C6 firmware using Crestron Toolbox.
Operation Modes Overview
Standard Mode Operation
Default mode for scene recall, with notes on ON/OFF buttons and up/down rocker.
Button Types in Standard Mode
Lists programmable button types like Recall Scene, Toggle Scene, and Shade Control.
Scene Recall Functionality
Recall-Scene Buttons Details
Explains how scenes are recalled, including fade times and cut functions.
Scene Button Functions
Toggle Scene and Master Lighting Control
Covers toggle scenes and master raise/lower for lighting loads.
Shade Control Button Operations
Operates shade groups for open, stop, close functions.
Input and Control Interfaces
IR Receiver and Occupancy Sensing
Details IR receiver use and how occupancy sensing triggers functions.
Override Mode Operation
Describes engaging Override mode to lock out local functions.
Special Operation Modes
Load Shedding and BMS Interface
Manages load shedding and details BMS interface via DIN-IO8/GLS-SIM.
Lighting Control Modes
Lights Mode Operation
Allows manual adjustment of individual lighting loads.
Manual Load Adjustment with Daylight Harvesting
Explains manual adjustment while maintaining photocell response.
Shade Control Mode
Shades Mode Operation
Enables manual control of shade groups via front panel buttons.
Problem Solving and Troubleshooting
CLS-C6 Troubleshooting Table
Provides common issues and corrective actions for the CLS-C6 unit.
Network Wiring and Power Considerations
Emphasizes using certified wire and correct power supplies for reliability.
Cable Length Calculation and Wiring Practices
Cable Length Equation and Wiring Preparation
Formula for cable length and guidelines for Cresnet wiring preparation.
Hubs and Network Limits
Recommends hubs for networks exceeding 20 devices or 3000 feet.
Appendix A: Supported Devices
Supported Keypads
Lists keypad types and their default button functions.
Additional Supported Devices
Supported Shade Controllers
Lists supported shade controllers like C2N-SSC-2, C2N-SDC.
Supported Touch Screens
Lists supported touch screen models and their features.
Joins and Command Mapping
Digital Command Joins (Touch Screen to CLS-C6)
Maps touch screen commands to CLS-C6 functions via join numbers.
Feedback Join Mapping
Digital Feedback Joins (CLS-C6 to Touch Screen)
Maps CLS-C6 feedback signals to touch screen displays via join numbers.
Bidirectional Serial Communications
Bidirectional Serial Joins (CLS-C6 and Touch Screen)
Defines serial join numbers for scene names, load names, and shade names.
Appendix B: Console Commands
Console Command Reference
Lists available commands, syntax, and parameters for system control.
Console Command Details
LED and Help Commands
Covers commands for green LED brightness and help categories.
Device Info and IR/Motion Sensor Commands
Details commands for device info, IR control, and motion sensor settings.
Project and System Management Commands
Project Info and Configuration Commands
Commands for project info, loading projects, rebooting, and reporting devices.
Restore, System, and Upload Commands
Commands for restoring defaults, loading firmware, and uploading firmware.
Version and LED Level Commands
Version and White LED Level Commands
Commands to display firmware version and set white LED brightness.
White LED Glow Level Command
Command to display or set white LED glow brightness level.
Appendix C: RS-232 Commands
RS-232 Command Format
Defines the ASCII character set and packet format for third-party communication.
RS-232 Command Table
Control and Programming Command Reference
Lists RS-232 commands for light zone control and programming.
Shade Group Control Commands
Shade Group Position Control
Sets and queries the position of shade groups.
Shade Group Open/Close/Stop Operations
Commands for opening, closing, stopping, and jogging shade groups.
Shade Group Name Query
Queries the names assigned to shade groups.
Scene Control and Programming
Shade Type Query and Scene Recall
Queries shade type and details scene recall operations.
Scene Raise/Lower and Toggle Commands
Controls scene light levels and toggles scene states.
Scene Management Commands
Scene Turn Off and State Query Commands
Commands to turn off scene lights and query scene states.
Scene Save and Level Query Commands
Saves scenes and queries light and shade levels within scenes.
Scene Masking and Naming
Scene Light Mask Commands
Adds or removes light zones from scenes and reads scene light mask status.
Scene Shade Mask Commands
Adds or removes shade groups from scenes and reads shade mask status.
Scene Name Query Command
Queries the names assigned to scenes.
Room Combining and Override Control
Room Combining Commands
Commands to combine, un-combine, and query room combine status.
Override Commands
Controls override mode status and queries its state.
Load Shed and Occupancy Control
Load Shed Commands
Commands to turn load shed on/off and query its status.
Occupancy Operation Commands
Sets, clears, and queries occupancy state.
Photocell Operation Commands
Queries the active state of photocells for light zones.
Version Information Command
Version Command
Queries the firmware version string of the CLS-C6 device.
Appendix E: Button Functions
Button Function Classification
Classifies buttons into Standard Rocker, Shifted Rocker, Up/Down Rocker, and Remote Button.
Scene Recall and Turn Off Scene Functions
Details behavior, LED action, and rocker behavior for scene recall and turn off.
Lighting Load Master Control Functions
Master Raise/Lower Lighting Load Functions
Provides master control for raising/lowering lighting loads in scenes.
Shade Control Button Functions
Toggle-Dim Scene and Full Shade Control Functions
Toggles scenes and controls full open/close/stop for shades.
Shade Momentary and Jog Functions
Momentary and Open/Stop/Close/Stop Shade Functions
Covers momentary shade movement and alternating open/stop/close actions.
Appendix G: RC5 Code Expansion
RC5 Codes Function Table
Maps RC5 codes to CLS-C6 functions for remote control via SIMPL Windows.
Return and Warranty Policies
Merchandise Returns and Repair Service
Procedures for returning products for credit, exchange, or service.
Crestron Limited Warranty
Details the 3-year warranty, exclusions, and limitations of liability.

Table of Contents