Vector 40-50 0053 Manual

Vector 40-50 0053 Manual

Programmable operation terminal for modbus

Advertisement

Quick Links

Programmable operation terminal for MODBUS
OPA2-MOD
Application
The operation terminal controls typically a single room control unit. The device measures room temperature and humidity
(for –H type) through integrated sensors. Two additional digital inputs may be configured for window contact, key
switches or motion detectors. The operation mode may then be controlled based on these inputs. An external temperature
may be measured through the additional temperature input. This may be useful for underfloor heating, sensor averaging
for large rooms, outdoor temperatures etc.
The operation terminal communicates through a galvanically isolated RS485 interface via the MODBUS protocol in slave
mode.
Ordering
Model
Item#
OPA2-MOD
40-50 0014
OPA2-MOD-H
40-50 0053
Supported Modbus commands:
-
03 (0x03): Read multiple registers
-
06 (0x06): Write single register
-
16 (0x10): Write multiple registers
Commands 03 and 16 can handle up to 32 registers. The Modbus slave transmits the values as signed 16 bit integers with
one digit below the decimal point. This results in the following range: -9999.9 to 9999.9
In an event of an out-of-range command addressing or an unsupported command, the Modbus slave responds with an
exception message according to the Modbus specification.
Dimensions [mm](in)
Doc: 70-00-0290, V1.0 R0, Date: 20160208
Subject to alteration
Features
Display
RT
yes
1
yes
1
88 (3.5)
LCD display with backlight four keys
Internal temperature sensor
With –H model, internal humidity sensor
1 external temperature input
2 digital inputs, which can be configured for window/door contacts
or motion detectors.
Up to 5 zones may be handled by one operation terminal
Detailed configuration possible
RS485 2-wire MODBUS standard in accordance to EIA/TIA 485
Slave type of communication
Galvanic isolated bus connection
Flush mounted on standard EU/UK/CH installation box
DI
rH
Modbus communication module with one internal
2
-
temperature sensor and one external temperature
input plus two binary inputs.
As above with internal humidity sensor 3%
2
1
accuracy.
32
21
(1.2)
(0.8)
© Vector Controls GmbH, Switzerland
OPA2-MOD(-H)
Description
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 40-50 0053 and is the answer not in the manual?

Questions and answers

Summarization of Contents

OPA2-MOD Programmable Operation Terminal
Features
Lists key capabilities and specifications of the operation terminal.
Application
Describes the typical use case and environment for the operation terminal.
Ordering
Details the available models and their configurations.
Supported Modbus commands
Lists common Modbus commands used by the terminal.
Dimensions
Shows the physical measurements of the device in millimeters and inches.
Technical Data
Power Supply
Details power requirements, voltage, and consumption specifications.
Sensors
Lists specifications for internal temperature and humidity sensors.
Signal Inputs
Covers specifications for temperature input and digital inputs.
Network
Describes network interface, topology, and cable requirements.
Environment
Specifies operating and storage conditions for temperature and humidity.
Standards EU
Lists relevant EU certifications and directives for compliance.
General
Includes material, dimensions, and weight information for the device.
Security Advise and Installation
Security Advise
Provides important safety warnings for device usage and installation.
Connection Diagram
Illustrates the wiring and terminal connections for the device.
Terminal Description
Explains the function of each terminal connection on the device.
Mounting Location
Recommends suitable locations for installing the operation terminal.
Installation
Provides step-by-step instructions for mounting and connecting the device.
Display and Operation
Zone Indication
Describes how zone information is displayed on the terminal.
Operation Mode
Explains the different operational modes like Comfort and Standby.
Indicators
Details the various status indicators shown on the display.
Button Functions
Explains the functions of the physical buttons (Left, Up, Down, Right).
Display Elements
Describes the large digits, small digits, and vertical bar display elements.
Control Symbols
Lists and explains the various control symbols shown on the display.
Display in Idle Mode
Defines behavior and content shown when the display is idle.
Error Messages
Explains common error messages and their troubleshooting steps.
Configuration Parameters
Access to Parameters
Details the procedure for accessing and modifying device parameters.
Setup Parameters
Lists and describes configuration parameters (CP00 to CP20) and their ranges.
Register Definitions
Terminal Setup Registers
Defines Modbus registers for terminal setup parameters (addresses 1000-1024).
Operation State, Symbols & Alarms
Operation State Registers
Defines registers for operation state (ON/OFF, occupied/unoccupied).
Symbol Control Registers
Defines registers to control the display of various symbols.
Alarm String Registers
Specifies registers for displaying alarm text and selecting its location.
Display Modes Configuration
Display in OFF Mode
Configures the display content for large digits, small digits, and vertical bar in OFF mode.
OFF Mode Symbols
Selects which symbols are displayed in OFF mode.
Idle Mode Display Configuration
Display in Idle Mode
Configures display content for large digits, small digits, and vertical bar in idle mode.
Idle Mode Symbols
Configures text strings to be displayed when the device is ON.
Zone Display Configuration
Display Zone 1
Configures display content for Zone 1's large digits, small digits, and vertical bar.
Zone 1 Setpoints
Sets comfort and standby setpoints, step, and limits for Zone 1.
Zone 2-5 Display
Details register addresses for configuring display settings for Zones 2 through 5.
Input Configuration
Sensor Enable and Calibration
Configures and calibrates internal/external temperature and humidity sensors.
Digital Input Function Assignment
Assigns functions (e.g., remote disable, mode change) to digital inputs.
Digital Input State Configuration
Defines open/closed character settings for digital inputs.
Fan String Configuration
Fan String Registers
Defines registers for configuring fan string characters.
Reduced ASCII Table
Provides a table of ASCII characters for display purposes.

Table of Contents