Vacon OPTC5 User Manual

Vacon OPTC5 User Manual

Profibus dp option board

Advertisement

vacon nx
ac drives
optc3/c5
profibus dp option board
user manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OPTC5 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Profibus DP Option Board Technical Data
General Technical Specifications
Provides essential technical data and specifications for the Profibus DP option board.
Profibus Cable Specifications
Details physical and electrical characteristics of Profibus cables and length limitations.
Profibus DP Standard Overview
Profibus DP Introduction
An overview of the Profibus standard and its key versions for industrial automation.
Profibus DP Profiles
Explains the role and importance of profiles in standardizing communication in Profibus DP.
PROFIDRIVE Profile for Drives
Details the PROFIDRIVE profile, crucial for parameterizing and controlling variable speed drives.
Profibus Board Layout and Connections
OPT-C3 Board Layout and Signals
Describes the physical layout and connector pinout for the OPT-C3 Profibus option board.
OPT-C3 Bus Cable Shield Grounding
Outlines methods for properly grounding the bus cable shield on the OPT-C3 board.
RC-Filter Shield Grounding Method
Details grounding using an RC-filter, recommended for longer cable runs to reduce interference.
Clamped Shield Grounding Method
Explains the recommended clamping method for grounding the bus cable shield, effective for short distances.
OPT-C5 Board Layout and Signals
Describes the physical layout and connector pinout for the OPT-C5 Profibus option board.
OPT-C5 D-Connector Grounding
Provides instructions for grounding the D-connector used with the OPT-C5 board.
Bus Termination Resistor Configuration
Explains how to set bus termination using jumpers or external resistors for proper bus operation.
Profibus Board LED Status Indicators
Details the meaning of the LED indicators on the Profibus board for status monitoring.
Commissioning the Profibus Board
Fieldbus Board Parameter Setup
Guides on configuring essential parameters for the Profibus board via the converter's keypad.
Profibus Status Monitoring
Instructions on how to check and interpret the current status of the Profibus fieldbus connection.
Profibus Commissioning Start-up Test
Outlines the procedure for testing the Profibus interface after installation and configuration.
Profibus-Vacon NX Interface
Profibus-Vacon Interface Overview
General explanation of data transfer between Profibus DP master and Vacon converter.
Profibus Operation Modes
Describes the different operation modes (PROFIDRIVE, BYPASS, ECHO) for data handling.
Profibus PPO Data Types
Details the Parameter/Process Data Object (PPO) types used for Profibus DP communication.
Profibus Process Data Exchange
Explains the structure and function of process data fields for device control and status reading.
Profibus Control Word Details
Defines the bits and their meanings within the control word for device state management.
Profibus Status Word Details
Defines the bits and their meanings within the status word for device status reporting.
Profibus State Machine Logic
Illustrates the state transitions of the frequency converter controlled by Profibus commands.
Profibus Reference Value 1
Details the use of Reference 1 for setting speed or other references and its scaling.
Profibus Actual Value 1
Explains how Actual Value 1 represents the device's current operating state, such as speed.
Profibus Process Data PD1-PD8
Covers the use of additional process data variables for advanced settings and actual values.
Profibus Parameter Data Transfer
Explains how to read and write device parameters using the parameter field via Profibus.
Profibus Communication Example Messages
Provides practical examples of Profibus message frames for common operations.
Profibus Option Board Fault Tracking
Faults and Responses
Lists common faults related to the Profibus option board and the converter's response to them.
Profibus Type Files
GSD File Description
Provides details on the GSD file content, essential for Profibus master configuration.
Appendix: Process Data
Process Data OUT (Slave to Master)
Lists the actual values sent from the Vacon converter to the Profibus master.
Process Data IN (Master to Slave)
Lists the input data sent from the Profibus master to the Vacon converter.

Table of Contents