Installation And Clearances (Vent-Free Operation Only) - Desa Comfort Glow CGS2718P Owner's Operation And Installation Manual

Yellow flame design unvented (vent-free) propane/lp gas log heater
Table of Contents

Advertisement

INSTALLING
Continued
102989

INSTALLATION AND CLEARANCES (Vent-Free Operation Only)

Maintain the minimum clearances. If you can, provide greater clear-
ances from floor, ceiling, and adjoining wall.
MINIMUM FIREPLACE CLEARANCE
TO COMBUSTIBLE MATERIALS
Log Size
18", 24"
LOG SIZING REQUIREMENTS
Log
Minimum Firebox Size
Size
Height
18"
17"
24"
17"
Carefully follow the instructions below. This will ensure safe installation into a
masonry, U.L. listed manufactured fireplace, or vent-free firebox certified for use
with these log heaters.
Minimum Wall and Ceiling Clearances (see Figure 4)
A. Clearances from the side of the fireplace opening to any combustible wall
should not be less than 16 inches.
B. Clearances from the top of the fireplace opening to the ceiling should not be
less than 42 inches.
16"
Left and Right
Sides
Figure 4 - Minimum Clearance to Wall and Ceiling
WARNING
Side Wall
16"
Depth
14"
14"
42"
Ceiling
42"
Front Width
20"
26"