Desa CGD3018PT/NT Owner's Operation And Installation Manual page 11

Desa unvented gas log heater owner's manual models crl2718p/n crl3124p/n ccl3018pa/na ccl3924pa/na
Table of Contents

Advertisement

INSTALLATION
Continued
NOTICE: If your installation does
not meet the minimum clear-
ances shown, you must do one
of the following:
• operate the logs only with the
flue damper open
• raise the mantel to an accept-
able height
• remove the mantel
12"
10"
8"
6"
1 /2
2
"
Minimum
Noncombustible
Material
Hood
(GA6050,
(GA6050,
GA6052, and
GA6052)
GA6053)
Figure 8 - Minimum Mantel Clearances
When Using Hood
FLOOR CLEARANCES
A. If installing appliance on the floor level, you
must maintain the minimum distance of 14"
to combustibles (see Figure 9).
B. If combustible materials are less than 14" to the
fireplace, you must install appliance at least 5"
above the combustible flooring (see Figure 10).
Figure 9 - Minimum Fireplace Clearances
if Installed at Floor Level
111160-01C
Mantel Shelf
Underside
of Mantel
Shelf
All minimum
distances are
in inches
8"
12"
15"
18"
20"
Min.
Distances to
Underside of
Mantel
Combustible
Material
14"
Min.
Noncombustible
Material
www.desatech.com
Figure 10 - Minimum Fireplace
Clearances Above Combustible Flooring
INSTALLING DAMPER CLAMP
ACCESSORY FOR VENTED
OPERATION
Note: When used as a vented heater, appliance
must be installed only in a solid-fuel burning fire-
place with a working flue and constructed of non-
combustible material.
If your heater is a manually controlled model, you
may use this heater as a vented product. There are
three reasons for operating your heater in the
vented mode.
Log Set
All
18", 24",
1. The fireplace does not meet the clearance to com-
Models
30" Mode
bustibles requirements for vent-free operation.
2. State or local codes do not permit vent-free
Top of
Fireplace
operation.
Opening
3. You prefer vented operation.
If reasons number 1 or 2 above apply to you, you
must permanently open chimney flue damper. You
must install the damper clamp accessory (to or-
der, see Accessories, page 43). This will insure
vented operation (see Figure 11). The damper
clamp will keep damper open. Installation instruc-
tions are included with clamp accessory.
Damper
Clamp
Masonry
Fireplace
Figure 11 - Attaching Damper Clamp
Hearth
5"
Min.
Damper
Damper
Clamp
Damper
Manufactured
Combustible
Material
Damper
Fireplace
11

Advertisement

Table of Contents
loading