Sign In
Upload
Download
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Hydrotec Manuals
Water System
HY-MAG DN65
Operating instructions manual
Hydrotec HY-MAG DN65 Operating Instructions Manual
Hide thumbs
1
2
3
4
5
6
7
8
9
10
11
12
13
page
of
13
Go
/
13
Bookmarks
Advertisement
Quick Links
Download this manual
HY-MAG
INTEGRAL
DN100
Serial number: ..............................
HYDROTEC
Hydrotec House
4-5 Manor Courtyard
Hughenden Avenue
High Wycombe
HP13 5RE
Tel. 01494 / 796040 Fax 01494 / 796049
- 1 -
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Need help?
Do you have a question about the HY-MAG DN65 and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Hydrotec HY-MAG DN65
Water System Hydrotec HY-MAG INTEGRAL Series Operating Instructions Manual
(13 pages)
Water System Hydrotec HY-MAG DN25 Operating Instructions Manual
(13 pages)
Water System Hydrotec HY-MAG DN40 Operating Instructions Manual
(13 pages)
Summarization of Contents
General Operation
Product Description
Overview of the HY-MAG Integral control box and its capabilities.
Technical Specifications
Key technical data including voltage, protection class, and operating parameters.
Safety and Usage Notes
Important cautions and notes regarding installation and operation of the control box.
Connection of Water Part
HY-MAG DN25 – DN65 Connection
Procedure for connecting the control box to water parts for DN25-DN65 units.
HY-MAG DN100 Connection
Procedure for connecting the control box, load cable, and thermal protection for DN100 units.
Initiation Phase
Standard Display
The default display shown after the control box is switched on.
Control Box Test
Sequence showing the control box test during the initiation phase.
Short-Circuit Test
Sequence indicating the result of the short-circuit test.
Operation Test Sequences
Individual sequences for technical operation checks of the HY-MAG system.
Normal Operation
LED Light Sequence
Description of LED patterns indicating the GREEN phase of operation.
REFIT® Phase Description
Explanation of the REFIT® phase for magnetic remanence clearing.
Display Monitor During Operation
Monitoring of day, date, time, operation state, and current rate.
Menu Sequences
Main Programme Menu
Accessing and navigating the main menu of the control box.
Mode of Operation
Continuous Operation
Setting the unit to operate on a continuous 24-hour basis.
Timer Control
Setting the unit to operate via internal timers for switch-on/off times.
Operating Hours
Absolute Value
Total operation time of the unit since start-up.
Relative Value
Operating hours counted from the last reset.
Date / Time Settings
Altering Date and Time
Procedure for modifying the internal timer and date settings.
Time Zones Programming
Group Programming
Programming switch-on/off times for groups of days.
Individual Day Programming
Programming switch-on/off times for individual days of the week.
Setting Switch Times
Example and method for setting specific switch-on and switch-off times.
Language Settings
Menu Language Selection
Process for selecting and confirming the menu language.
Service Menu
Access and Restrictions
Information on accessing the code-protected service menu.
Failure Indication
Automatic Failure Recognition
How the control box automatically detects and displays failure types.
Failure 1: Undercurrent
Details on undercurrent failures and potential causes.
Failure 2: Overload
Details on overload failures and recommended actions.
Failure 3: Short Cut
Information on short-circuit failures and their remedies.
Failure 4,5: Control Box Failure
Description of control box internal failures.
Failure 6: Thermal Protection
Details on thermal protection release for HY-MAG DN100.
Failure 4,5: Control Box Issues
Further details on control box faults and inspection requirements.
Failure 6: Overheating
Information on overheating and its external influences for DN100.
Failure Remedial Action
General Checks
Initial checks for display or operation issues, including fuse inspection.
Fault Type Identification
Specific troubleshooting steps for undercurrent, overload, and short-cut faults.
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the HY-MAG DN65 and is the answer not in the manual?
Questions and answers