® Operating Instruction HY-MAG INTEGRAL General The HY-MAG Integral is a high-quality menu- and micro-processor driven control box providing maximum efficiency for the HY-MAG Water Conditioning Units sizes DN20 to DN100. The control box is pre-programmed ex works to the individual water conditioning units.
Page 3
Connection of Water Part The HY-MAG Water Conditioning Units are supplied ex works in 2 components, that means water part and control box. Connection between control box and water part must be provided by expert plumbers as follows: HY-MAG DN25 – DN65 The control box includes a mains connection cable and a load cable for the connection of the water part.
Page 4
Initiation Phase Once the control box was connected to the mains power and switched on, the initiation phase and an initial system check is started automatically. Every individual and actually running operating sequence is shown in the LCD-display. Standard display: H Y D R O T E C Integral V.
Normal Operation The control box automatically switches to normal operation once the initiation phase has elapsed, whereby the individual actual operation sequences are shown in the display and by the LED lights. The individual operation phases are shown optically. The below display monitoring is shown during continuous operation.
Page 6
The shown current rating is dependent on the type of water conditioning unit. HY-MAG DN20 / 25 235 mA ± 10% HY-MAG DN32 / 40 345 mA ± 10% HY-MAG DN50 / 65 465 mA ± 10% HY-MAG DN100 3.25 A ± 10% Menu Sequences Input and programming of HY-MAG Integral control box by pressing the front foil buttons (behind transparent cover) as below:...
Page 7
The below menu sequences can be retrieved by the buttons Operation mode Main menu Operation mode Operation hours Main menu Operation hours Date / Time Main menu Date / Time Time zones Main menu Time zones Language Main menu Language Service Main menu Service...
Page 8
Operating Hours The operating hours of the HY-MAG unit are registered by 2 separate counters. Absolute value: Total operation time of HY-MAG unit in the actual installation. (Operation hours since start-up). Standby-times are not registered and thus, not shown. Relative value: Operating hours of unit counted from a certain period of time.
Page 9
NOTE: If the button is pressed during the modification phase, the input is interrupted and the changed figures not registered. Time Zones The switch-on and –off times of the unit can be programmed in the menu „Time zones“ after the operation mode „Timer control“ was retrieved. One such setting is possible per day. A group of several days or also individual days can be programmed by the operator.
Page 10
Language The service menu of the HY-MAG Integral control box provides 2 languages. Operation and setting is possible in both languages. The menu language is initially selected by means of the button . The corresponding language is then selected and confirmed by the buttons .
Page 11
Failure 1: Undercurrent Coil not closed, faulty connection control box → water unit Failure: Undercurrent Thu 11.10.2003 16:17 Failure 2: Overload Short cut of coil, faulty coil Failure: Overload Thu 11.10.2003 16:17 Failure 3: Short cut Short cut in coil connection (visible during initiation) Failure: Short cut Thu 11.10.2003...
Page 12
Thermal Water Part Connection Protection Connection If there is still no LED scale visible, inform the technical department of Hydrotec. Fault Types: Failure 1: Undercurrent Check connection and correct fit between water part and control box, i.e. fit of Harting coupling.
Page 13
Faulty control box. Internal communication or between control box and water part may be faulty or disturbed. Switch-off plant and start again. Return box for inspection to Hydrotec along with corresponding failure report or other information should the fault happen again.