Mitsubishi Heavy Industries KX Series User Manual
Mitsubishi Heavy Industries KX Series User Manual

Mitsubishi Heavy Industries KX Series User Manual

Packaged air conditioner, inverter packaged air-conditioners, vrf inverter multi-system air-conditioners,

Advertisement

USER'S MANUAL
PACKAGED AIR CONDITIONER
FD series
Inverter Packaged Air-conditioners
Ceiling cassette -4 way- (FDT)
Ceiling cassette -4 way Compact- (FDTC)
Duct connected -High static pressure- (FDU)
Duct connected -Middle static pressure- (FDUM)
Ceiling suspended (FDE)
KX KXR
VRF inverter multi-system Air-conditioners
Ceiling cassette -4 way- (FDT)
Ceiling cassette -4 way Compact- (FDTC)
Ceiling cassette -2 way- (FDTW)
Ceiling cassette -1 way Compact- (FDTQ)
Ceiling cassette -1 way- (FDTS)
Duct connected -High static pressure- (FDU)
Duct connected -Middle static pressure- (FDUM)
Ceiling suspended (FDE)
Wall mounted (FDK)
Floor standing -2 way- (FDFW)
Duct connected -Low static pressure- (FDUT)
Duct connected -Compact&Flexible- (FDUH)
Duct connected -High static pressure outdoor air processing unit (FDU -F)
Please refer to the manual provided with WIRED REMOTE
CONTROL (RC-EX series) and WIRELESS REMOTE
CONTROL (RCN-E2, EK2 series)
Veuillez vous référer au manuel fourni avec la
TÉLÉCOMMANDE FILAIRE (série RC-EX) et la
TÉLÉCOMMANDE SANS-FIL (série RCN-E2, EK2)
Siehe bitte die mit KABEL-FERNBEDIENUNG (RC-EX-Serie)
und DRAHTLOSE FERNBEDIENUNG (RCN-E2-, EK2-Serie)
mitgelieferte Bedienungsanleitung
This air-conditioner complies with following directive.
Machinery 2006/42/EC
Low Voltage 2014/35/EU
EMC 2014/30/EU
Pressure Equipment 2014/68/EU
RoHS 2011/65/EU
Ecodesign 2009/125/EC
CE marking is applicable to the area of 50 Hz power supply.
Ce climatiseur est conforme aux directives suivantes.
Machines 2006/42/CE
Basse tension 2014/35/UE
CEM 2014/30/UE
Équipements sous pression 2014/68/UE
RoHS 2011/65/UE
Écoconception 2009/125/CE
La marque CE s'applique aux régions alimentées en courant
de 50 Hz.
Consultare il manuale in dotazione con TELECOMANDO
CABLATO (serie RC-EX) e TELECOMANDO SENZA FILI
(serie RCN-E2, EK2)
Consulte el manual suministrado con el MANDO A
DISTANCIA ALÁMBRICO (serie RC-EX) y el MANDO A
DISTANCIA INALÁMBRICO (serie RCN-E2, EK2)
Raadpleeg de handleiding die is meegeleverd met de
BEDRADE AFSTANDSBEDIENING (RC-EX-reeks) en
DRAADLOZE AFSTANDSBEDIENING (RCN-E2-, EK2-reeks)
Diese Klimaanlage erfüllt die folgende Richtlinie.
Maschinen 2006/42/EC
Niederspannung 2014/35/EU
EMV 2014/30/EU
Druckgeräte 2014/68/EU
RoHS 2011/65/EU
Ökodesign 2009/125/EC
Die CE-Marke gilt für Bereiche mit einer Netzstromversorgung
von 50 Hz.
Questo condizionatore d'aria è conforme alla seguente direttiva.
Macchinario 2006/42/CE
Bassa tensione 2014/35/UE
EMC 2014/30/UE
Apparecchiature a pressione 2014/68/UE
RoHS 2011/65/UE
Ecodesign 2009/125/CE
Il marchio CE è applicabile alla fascia di alimentazione 50 Hz.
ORIGINAL INSTRUCTIONS
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ U
Consulte o manual fornecido com o CONTROLO REMOTO
COM FIOS (série RC-EX) e o CONTROLO REMOTO SEM
FIOS (série RCN-E2, EK2)
Σας παρακαλούμε να ανατρέξετε στο εγχειρίδιο που παρέχεται
μαζί με το ΕΝΣΥΡΜΑΤΟ ΤΗΛΕΧΕΙΡΙΣΤΗΡΙΟ (σειρά RC-EX) και το
ΑΣΥΡΜΑΤΟ ΤΗΛΕΧΕΙΡΙΣΤΗΡΙΟ (σειρές RCN-E2, EK2)
Este aire acondicionado cumple con la siguiente directiva.
Máquinas 2006/42/CE
Baja tensión 2014/35/UE
EMC 2014/30/UE
Equipos a presión 2014/68/UE
RoHS 2011/65/UE
Ecodiseño 2009/125/CE
La indicación CE sólo corresponde al área de suministro
eléctrico de 50 Hz.
Deze airconditioner voldoet aan de volgende richtlijn.
Machine 2006/42/EC
Laagspanning 2014/35/EU
EMC 2014/30/EU
Drukapparatuur 2014/68/EU
RoHS 2011/65/EU
Ecodesign 2009/125/EC
CE-markering is van toepassing op het gebied met een net-
stroom van 50 Hz.
USER'S MANUAL
MANUEL DE L'UTILISATEUR
ANWENDERHANDBUCH
ISTRUZIONI PER L'USO
MANUAL DEL PROPIETARIO
GEBRUIKERSHANDLEIDING
MANUAL DO UTILIZADOR
ОΔНГІЕΣ ХРНΣНΣ
KULLANIM KILAVUZU
Lütfen kablolu uzaktan kumandalı olan (RC-EX serisi) ve kablosuz
uzaktan kumandalı olan (RCN-E2, EK2 serisi) modelin kılavuzuna
bakınız.
Este ar condicionado está em conformidade com as seguintes directivas.
Máquinas 2006/42/CE
Baixa tensão 2014/35/UE
EMC 2014/30/UE
Equipamentos sob pressão 2014/68/UE
RoHS 2011/65/UE
Concessão ecológica 2009/125/CE
A marca CE aplica-se à zona de fornecimento de energia a
50 Hz.
Το συγκεκριμένο κλιματιστικό συμμορφώνεται προς καθεμιά από
τις οδηγίες που ακολουθούν.
2006/42/ΕΚ περί μηχανημάτων
2014/35/ΕΕ περί χαμηλής τάσης
2014/30/ΕΕ περί ηλεκτρομαγνητικής συμβατότητας (EMC)
2014/68/ΕΕ περί εξοπλισμού υπό πίεση
2011/65/ΕΕ RoHS
2009/125/ΕΚ περί οικολογικού σχεδιασμού
Tο σήμα CE ισχύει μόνον σε περιοχές όπου η τροφοδοσία είναι 50 Hz.
PSA012B835
201811
ENGLISH
FRANÇAIS
DEUTSCH
ITALIANO
ESPAÑOL
NEDERLANDS
PORTUGUÊS
ЕΛΛΗNIKA
РУССКИЙ
TÜRKÇE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KX Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Mitsubishi Heavy Industries KX Series

  • Page 1 USER’S MANUAL ORIGINAL INSTRUCTIONS PACKAGED AIR CONDITIONER USER’S MANUAL ENGLISH FD series Inverter Packaged Air-conditioners Ceiling cassette -4 way- (FDT) MANUEL DE L’UTILISATEUR FRANÇAIS Ceiling cassette -4 way Compact- (FDTC) Duct connected -High static pressure- (FDU) Duct connected -Middle static pressure- (FDUM)
  • Page 3: Table Of Contents

    Thank you very much for your purchase of this packaged air conditioning system produced Please read these marks mean danger, by Mitsubishi Heavy Industries. Please read through this manual before using the “SAFETY PRECAUTIONS” alarm, and caution. The product and use the product appropriately according to the instructions in the manual.
  • Page 4 This unit should be Following precaution is only for R32. Do not expose yourself Make sure to mount a installed in rooms which directly to cooled air flow leakage breaker. This equipment uses exceed the floor space for a long time or cool too Otherwise electric shock may flammable refrigerants.
  • Page 5 Normally the refrigerant Do not place a burning Before maintenance, Do not place objects on does not leak. But if it leaks appliance where the air make sure to stop the outdoor unit, nor and contacts fi re such as flow from the unit is directly operation and cut off the mount on it.
  • Page 6 PRECAUTIONS FOR RELOCATION Do not place any object Do not use the unit where Before repairing or around the outdoor unit, powder or fiber is floating. OR REPAIRING checking indoor unit, be nor allow fallen leaves to pile sure to turn off “Indoor unit Fine powder or fi ber passing CAUTION power supply breaker”...
  • Page 7: How To Use

    HOW TO USE< WIRED REMOTE CONTROL (RC-E series) > HOW TO OPERATE (Dehumidifying operation is prohibited for FDU-F.) < WIRED REMOTE CONTROL (RC-E series) > NAMES AND FUNCTIONS OF REMOTE CONTROL BUTTONS < > WIRED REMOTE CONTROL (RC-E SERIES) • In order to protect both indoor/outdoor air conditioners, keep the power supply on for six hours before initial operation.
  • Page 8: How To Perform The Timer Operation

    HOW TO PERFORM THE TIMER OPERATION HOW TO PERFORM THE TIMER OPERATION < WIRED REMOTE CONTROL (RC-E series) > < WIRED REMOTE CONTROL (RC-E series) > THE SELECTION OF TIMER MODE SETTING THE TIME Timer operation is performed based on the time of the clock which is set by the following steps. Make sure to Press TIMER button.
  • Page 9: Sleep Timer Mode

    HOW TO PERFORM THE TIMER OPERATION < WIRED REMOTE CONTROL (RC-E series) > SLEEP TIMER MODE ON TIMER MODE After a certain period of time has elapsed, operation The unit starts to operate at the set time. It is possible to set temperature at which you want to start the operation. Press TIMER button.
  • Page 10: Weekly Timer Mode

    HOW TO PERFORM THE TIMER OPERATION < WIRED REMOTE CONTROL (RC-E series) > WEEKLY TIMER MODE Press SET button. mark next to a number lights. Selection of Weekly timer mode “ ” or “ ” is displayed. You can set up to four ON/OFF timers per day. The settings so far are effective and the display changes as shown on Note : Set time every month in Weekly timer mode.
  • Page 11 HOW TO PERFORM THE TIMER OPERATION < WIRED REMOTE CONTROL (RC-E series) > Next setting and exiting Weekly timer mode Weekly timer Holiday Setting After “ ” is displayed, “ ” is displayed. It is possible to temporarily disable each day’s timer setting by using the Holiday Setting. When the Holiday Setting is cancelled, the timer setting is enabled again.
  • Page 12: Timer Cancellation Mode

    HOW TO PERFORM THE TIMER OPERATION < WIRED REMOTE CONTROL (RC-E series) > Weekly timer Checking TIMER CANCELLATION MODE Press TIMER button. In the Weekly timer mode, select and set Timer mode begins. The current “The day of the week” and “the current time” are “...
  • Page 13: How To Operate In Silent Mode

    HOW TO OPERATE IN SILENT MODE HOW TO ADJUST THE LOUVER < WIRED REMOTE CONTROL (RC-E series) > < WIRED REMOTE CONTROL (RC-E series) > SILENT MODE ADJUSTING WITH LOUVER BUTTON (Indoor unit with auto swing function) When the silent mode is set, the unit operates more silently reducing noise from the outdoor unit. [IN CASE OF FDT, FDTC, FDE, FDK, FDFW] The system applies the silent operation mode at the starting time to be set, and finish it after a certain period of time has passed.
  • Page 14: How To Set The Air Flow Direction

    HOW TO SET THE AIR FLOW DIRECTION HOW TO SET THE AIR FLOW DIRECTION (IN CASE OF FDT, FDTC, FDE, FDK, FDFW) <WIRED REMOTE CONTROL (RC-E series) > < WIRED REMOTE CONTROL (RC-E series) > It is possible to change the movable range of the louver on the air outlet from the wired remote control. Once the top and bottom positions are set, Press SET button (Fixing of the upper the louver will swing within the range between the top and the bottom positions when swing operation is chosen.
  • Page 15: How To Operate Ventilation

    AIR SELECTION button can switch the air outlets. INSPECTION DISPLAY, FILTER SIGN, AIR CONDITIONER NUMBER, STANDBY, ROOM TEMPERATURE AND BACK UP DISPLAY 1. Stop the air conditioner. 2. Select the air flow from AIR SELECTION button on the unit display. <...
  • Page 16: Trouble Shooting

    TROUBLE SHOOTING TROUBLE SHOOTING The phenomena mentioned below is not malfunction. Check the following items before requiring service. THE UNIT DOES NOT WORK AT ALL The indoor-unit fan will not move In order to protect the compressor, the indoor-unit fan may take several minutes to begin moving after Is the power supply switch Is there a blackout or is the Is the leakage breaker...
  • Page 17: Setting To Disable Button Operation

    CAUTION Condition Room temperature Temperature outside the room Humidity inside the room Operation Approximately FD series Inverter Packaged Air-Conditioners Cooling 21 to 32°C Approximately -15 to 50°C Approximately 80% or less operation Long continuous operation under KX KXR VRF inverter multi-system Long operation under high humidity may leads to approximately 21°C may lead to malfunction...
  • Page 18: Maintenance And Inspection Guideline Of Main Parts Of Packaged Air Conditioner

    MAINTENANCE AND INSPECTION GUIDELINE OF MAIN PARTS OF PACKAGED AIR CONDITIONER This table indicates the details of regular inspection items and their intervals “implementation of parts replacement and repair” according to the result of the (inspection interval), and the timing of parts replacement under a normal regular inspection is indicated as the “maintenance interval.”...
  • Page 19 Explanation of symbols : Conduct the cleaning and adjustment according to the inspection result : Random failure : In case of abnormality after inspection, replace or repair the corresponding part. : Wear-out failure : Conduct the periodic replacement (consumable components) outdoor [Mainly parts and built-in components]...
  • Page 20 Explanation of symbols : Conduct the cleaning and adjustment according to the inspection result : Random failure : In case of abnormality after inspection, replace or repair the corresponding part. : Wear-out failure : Conduct the periodic replacement (consumable components) Part Name Regular Inspection Preventive Maintenance*...
  • Page 21 EU DECLARATION OF CONFORMITY DRED MITSUBISHI HEAVY INDUSTRIES THERMAL SYSTEMS, LTD. ■ This air conditioner complies with DRED standards as per AS/NZS4755.3.1. It supports demand response modes 1, 2 and 3 (DRM1, 2, and 3). 16-5 Konan 2-chome, Minato-ku, The outdoor unit of this air conditioner is equipped with a DRED-specifi c terminal block.
  • Page 22 MITSUBISHI HEAVY INDUSTRIES THERMAL SYSTEMS, LTD. MITSUBISHI HEAVY INDUSTRIES AIR-CONDITIONING EUROPE, LTD. MITSUBISHI HEAVY INDUSTRIES AIR-CONDITIONERS AUSTRALIA, PTY. LTD. MITSUBISHI HEAVY INDUSTRIES - MAHAJAK AIR CONDITIONERS CO., LTD.

Table of Contents