Martin Audio W8L Longbow Application Manual page 131

Hide thumbs Also See for W8L Longbow:
Table of Contents

Advertisement

Alternative W8LM +WLX presets (40-49) are now available. These provide active
W8LM settings with a separate subwoofer signal chain via input B and output 6:
DX1 or DP226
DX1 or DP226
Input
Output
B
6 Subs
(Default
= WLX)
A
5 Upper High
4 Middle High
A
A
3 Lower High
A
2 Upper Low-
mid
A
1 Lower Low-
mid
Band Zoning
W8LM band zoning is from the bottom upwards as follows:
Low-mid frequencies
Bottom 4 cabinets in the lower zone
The rest of the cabinets in the upper zone
High frequencies
Bottom 4 cabinets in the lower zone
Up to 4 cabinets in the middle zone
The rest of the cabinets in the upper zone
DX1 controllers have fully balanced inputs and outputs and MA series amplifiers
operate with pin 2 hot. Racks will therefore be pin 2 hot – assuming that I/O panel- to-
DX1 input and DX1 output-to-MA series amplifier input cables are wired 1-to-1 (X),
2-to-2 (L), 3-to-3 (R). The old U.S. standard was never XLR, it was XRL!
Standard balanced & screened XLR cables (typical spec = 70 ohms/1000m, 150pF/m
core-core, 300pF/m core-core+screen) should be used between the panel and the DX1
input and between DX1 outputs and MA series amplifier inputs. Good EMC practice
requires that XLR cable screens should be connected at both ends.
Please note that the D-Sub connector on the rear of the DX1 is for loading Martin
Audio control presets only. It does not facilitate PC equalizer control "on the fly".
6xW8LM+WLX
8xW8LM+WLX
(Mono)
(Mono)
WLX
WLX
Upper 2 High
Upper 4 High
Lower 4 High
Lower 4 High
Upper 2
Upper 4
Low-mid
Low-mid
Lower 4
Lower 4
Low-mid
Low-mid
All material © 2007. Martin Audio Ltd. Subject to change without notice.
12xW8LM+WLX
(Mono)
WLX
Upper 4 High
Middle 4 High
Lower 4 High
Upper 8
Low-mid
Lower 4
Low-mid

Advertisement

Table of Contents
loading

This manual is also suitable for:

W8lcW8lmW8ldW8lcdW8lmd