Appendix 2
Below are the default crossover settings and names for all configurations.
Note: these values are intended as arbitrary starting points and do not
correspond to any of the values in the factory presets.
X-over
2x2 way+Ms
2 x 3 way
4 way + 2
5 way + 1
6 way
Note: All filters set to 24dB Linkwitz-Riley.
>
PRINT
Output 1
Output 2
Low
High
120Hz – 1k82Hz
1k82Hz – 22kHz
Low
Mid
22.1Hz – 120Hz
120Hz – 1k82Hz
Low
LoMid
15Hz – 149Hz
149Hz – 1k31Hz
Sub
Low
15Hz – 80.3Hz
80.3Hz – 180Hz
LoSub
Sub
15Hz – 80.3Hz
80.3Hz – 149Hz
Martin Audio – DX1 Speaker Management System
APPLICATIONS GUIDE
Output 3
Output 4
Low
High
120Hz – 1k82Hz
1k82Hz – 22kHz 24.8Hz – 120Hz <10Hz – 22kHz
High
Low
1k82Hz – 22kHz
22.1Hz – 120Hz 120Hz – 1k82Hz 1k82Hz – 22kHz
HiMid
High
1k31Hz – 8kHz
8kHz – 22kHz
LoMid
HiMid
180Hz – 1k31Hz
1k31Hz – 8kHz
Low
LoMid
149Hz – 1kHz
1kHz – 4kHz
25
GUIDES
Output 5
Output 6
Msub
Aux
Mid
High
Aux
Aux
20.1Hz – 22kHz 20.1Hz – 22kHz
High
Aux
8kHz – 22kHz
20.1Hz – 22kHz
HiMid
High
4kHz – 10k1Hz 10k1Hz – 22kHz