Cambridge Elevating Heritage Design Manual

Residential elevator

Advertisement

Residential Elevator
Design Guide
All Models - Elmira, Heritage & Cambrian
1261 Industrial Rd • Cambridge, ON • N3H 4W3 • (p) 1.800.265.3579 • (p) 519.653.4222 • (fl 519.653.9927
www.CambridgeElevating.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Heritage and is the answer not in the manual?

Questions and answers

Summarization of Contents

Introduction
Planning for a Cambridge Elevating Home Elevator
Procedure for planning a home elevator installation, including model selection and site requirements.
Description of Elevator Equipment
General
General specifications including load, speed, pit depth, overhead clearance, and travel limits.
Mechanical Equipment
Details of mechanical components like motor, ropes, cylinder, and hydraulic system.
Cab and Appointments
Information on cab sizes, heights, interior finishes, and floor materials.
Gates and Doors
Describes door types for Elmira, Heritage, and Cambrian models, including cab gates.
Controls
Details on the microprocessor controller, operation, lighting, and user interface components.
Safety Devices
Lists essential safety features like handrails, disconnects, limit switches, and emergency lowering.
Options
Available customization options for cabs, finishes, fixtures, and accessories.
Elmira Model Cab / Hoistway Size Layout - Types 1 & 2
TYPE 1 – INLINE
Cab and hoistway size dimensions for Elmira model, inline configuration.
TYPE 2 – THROUGH
Cab and hoistway size dimensions for Elmira model, through configuration.
Elmira Model Cab / Hoistway Size Layout - Types 5 & 3/4
TYPE 5 – INLINE
Cab and hoistway size dimensions for Elmira model, Type 5 inline configuration.
TYPE 3 or 4 (90-DEGREE) LH or RH
Cab and hoistway size dimensions for Elmira model, Type 3/4 configurations.
Heritage Model Cab / Hoistway Size Layout
TYPE 1 – INLINE
Cab and hoistway size dimensions for Heritage model, inline configuration.
TYPE 2 – THROUGH
Cab and hoistway size dimensions for Heritage model, through configuration.
Cambrian Model Cab / Hoistway Size Layout
TYPE 1 – INLINE
Cab and hoistway size dimensions for Cambrian model, inline configuration.
TYPE 2 – THROUGH
Cab and hoistway size dimensions for Cambrian model, through configuration.
Part 1: General
1.1 Summary
Overview of the planning, labor, and materials for installing a residential elevator.
1.2 System Description
Description of the private residence hydraulic elevator system and its components.
1.3 Quality Assurance
Requirements for elevator design, testing, and installation compliance with standards.
1.4 Applicable Codes and Standards
Lists relevant codes and standards governing elevator installation and safety.
Part 2: Preparatory Work by Others
2.1 Hoistway
Requirements for hoistway construction, rail support, and pit floor as specified by layout drawings.
2.2 Machine Room
Requirement to provide a machine room according to applicable codes and standards.
2.3 Electrical
Specifies electrical power sources required for the machine room.
Part 3: Submittals
3.1 Approval Drawings
Details that approval drawings must show a complete equipment layout.
Part 4: Product - Cab and General Components
4.1 Equipment Manufacturer
States that the elevator is manufactured by Cambridge Elevating Inc.
4.2.1 Cab Details
Details cab sizes, configurations, and construction materials.
Part 4: Product - Mechanical and Door Components
4.2.2 Hydraulic Power Unit and Motor
Specifies components of the hydraulic power unit, motor, and valves.
4.2.3 Controller
Describes the certified relay controller and its functions, including battery backup.
4.2.4 Cylinder
Details the single stage jack, line rupture valve, and working pressure.
4.2.5 Ropes
Specifies the diameter and type of wire ropes used.
4.2.6 Guide rail
Specifies the type of guide rail system used.
4.2.7 Car Sling
Describes the construction and components of the car sling.
4.2.8 Gates and Doors
Details automatic and manual gate/door types for landings and cabs.
Part 5: Execution
5.1 Examination
Requirement to verify site dimensions and conditions against specifications.
5.2 Installation
Guidelines for installation by trained technicians, confirming site conditions.
5.3 Maintenance
Elevator maintenance requirements according to manufacturer instructions and codes.
5.4 Warranty
Details the warranty period and coverage for elevator parts.