Removal of Outer Panels
Top Panel Removal
Remove the 4 screws and lift the top panel.
Discharge Grille Removal
Remove the 4 screws and remove the discharge grille.
Removal of Outer Panels
Front Panel Removal
Remove front panel screws, unfasten shield plate hooks, and remove the front panel.
Removal of Outer Panels
Stop Valve Cover Removal
Remove the screw and pull the stop valve cover downwards to unfasten hooks.
Removal of Outdoor Fan / Fan Motor
Electrical Box Cover Removal
Remove the shield plate screw and unfasten hooks to remove the electrical box cover.
Removal of Outdoor Fan / Fan Motor
Fan Motor Connector and Lead Wire Disconnection
Disconnect the fan motor connector and release the lead wire from the 7 hooks.
Removal of Outdoor Fan / Fan Motor
Outdoor Fan Motor Removal
Remove the nut of the outdoor fan and then remove the lower and upper screws securing the fan motor.
Removal of Electrical Box
Shield Plate and Terminal Board Screw Removal
Remove shield plate, disconnect power/earth wires, and remove terminal board screws.
Removal of Electrical Box
Right Side Panel and Electrical Box Removal
Remove screws of right side panel, remove electrical box screw, and unfasten hooks to remove the right side panel.
Removal of Electrical Box
Front Side Connector and Relay Disconnection
Disconnect connectors [S40], [S20], [S90], [S80] and the relay connector for the compressor.
Removal of Electrical Box
Clamp Release and Thermistor Wire Detachment
Release clamps, detach the clamp and release thermistor lead wires from the hook.
Electrical Box and Thermistor Harness Removal
Remove the screw, release the outdoor temperature thermistor harness from the hook, and lift the electrical box.
Removal of PCBs
Service Monitor PCB Connector Disconnection
Disconnect connectors [S52] [S102] from the service monitor PCB.
Service Monitor PCB Removal
Detach the 4 clamps with pliers and remove the service monitor PCB.
Removal of PCBs
Terminal Board Hook Release and Harness Disconnection
Unfasten the hook, open the terminal board, and disconnect the relay connector for standby electricity saving.
Reactor Connector Disconnection
Disconnect the 2 connectors for the reactor [HR1] [HR2].
Removal of PCBs
Main PCB Screw Removal
Remove the 3 screws of the main PCB.
Main PCB Hook Release and Removal
Unfasten the 4 hooks and lift up and remove the main PCB.
Removal of Sound Blankets / Thermistors
Top Sound Blanket Removal
Remove the sound blanket (top upper) and then remove the sound blanket (top lower).
Back Sound Blanket Removal
Remove the sound blanket (back).
Removal of Sound Blankets / Thermistors
Outer and Inner Sound Blanket Removal
Remove the sound blanket (outer) and then remove the sound blanket (inner).
Discharge Pipe Thermistor Release
Release the discharge pipe thermistor.
Outdoor Heat Exchanger Thermistor Removal
Cut the clamp and pull out the outdoor heat exchanger thermistor.
Removal of Four Way Valve
Four Way Valve Coil Removal
Remove the screw and remove the four way valve coil.
Four Way Valve Brazed Part Heating and Disconnection
Heat up the brazed part of the four way valve and disconnect it, and heat up every brazed part in turn and disconnect.
Removal of Electronic Expansion Valve
Electronic Expansion Valve Coil Removal
Pull out the electronic expansion valve coil.
Putty Removal and Brazed Part Heating
Remove the sheets of putty and heat up the 2 brazed parts of the electronic expansion valve and remove it.
Removal of Compressor
Terminal Cover Removal
Remove the terminal cover.
Compressor Lead Wire Disconnection
Disconnect the lead wires of the compressor.
Removal of Compressor
Compressor Lead Wire Clamp Release and Putty Removal
Release the clamp with pliers to detach compressor lead wires and remove the putty.
Compressor Nut Removal and Brazed Part Heating
Remove the 2 nuts of the compressor and heat up the brazed part of the discharge side and disconnect it.
Removal of Compressor
Compressor Suction Side Brazed Part Heating and Removal
Heat up the brazed part of the suction side and disconnect it, then lift the compressor up and remove it.