Rheem ECONET RP2060BJVCA Installation Instructions Manual

Rheem ECONET RP2060BJVCA Installation Instructions Manual

Ariable speed r-410a heat pump outdoor units
Table of Contents

Advertisement

WARNING:
RECOGNIZE THIS SYMBOL
AS AN INDICATION OF
IMPORTANT SAFETY
INFORMATION
WARNING
THESE INSTRUCTIONS
ARE INTENDED AS AN AID
TO QUALIFIED, LICENSED
SERVICE PERSONNEL FOR
PROPER INSTALLATION,
ADJUSTMENT, AND
OPERATION OF THIS UNIT.
READ THESE INSTRUCTIONS
THOROUGHLY BEFORE
ATTEMPTING INSTALLATION
OR OPERATION. FAILURE
TO FOLLOW THESE
INSTRUCTIONS MAY
RESULT IN IMPROPER
INSTALLATION,
ADJUSTMENT, SERVICE,
OR MAINTENANCE
POSSIBLY RESULTING IN
FIRE, ELECTRICAL SHOCK,
PROPERTY DAMAGE,
PERSONAL INJURY, OR
DEATH.
Do not destroy this manual.
Please read carefully and
keep in a safe place for future
reference by a serviceman.
[ ] indicates metric conversions.
92-105074-14-01 (02/18) Printed in USA
VARIABLE SPEED R-410A
HEAT PUMP OUTDOOR UNITS
INSTALLATION INSTRUCTIONS
(-)P20 (20 SEER) EQUIPPED WITH
ECONET™ COMMUNICATIONS
Enabled

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ECONET RP2060BJVCA and is the answer not in the manual?

Questions and answers

Summarization of Contents

4.0 INSTALLATION
4.1 Tools and Refrigerant
Essential tools and specifications for handling R-410A refrigerant during installation.
4.2 Choosing a Location
Guidelines for selecting an optimal outdoor unit location, considering clearances and operational factors.
4.4 Refrigerant Line Set Selection
Procedures for selecting and sizing refrigerant lines, considering length, fittings, and oil return.
4.7 Evacuation
Critical steps for evacuating the system to remove air and moisture for optimal performance and longevity.
4.9 Control Wiring
Instructions for connecting control wires for both EcoNet™ and conventional thermostat systems.
5.0 SYSTEM START-UP AND REFRIGERANT CHARGING
5.1 System Start-Up Overview
Overview of the process for starting up the system and verifying airflow and refrigerant charge.
5.5 Entering Charge Mode Using EcoNet™ Control Center Service Menu
Step-by-step guide to initiate charging mode via the EcoNet™ Control Center service menu.
5.7 Indoor Air-Flow Verification
Critical steps to verify and adjust indoor air-flow for optimal system performance and reliability.
5.8 Refrigerant Charging
Detailed procedures for checking and adjusting the refrigerant charge using weight, pressures, and subcooling.
9.0 DIAGNOSTICS & TROUBLESHOOTING
9.1 Fault Recall Procedure
How to access and interpret stored fault codes from the EcoNet™ Control Center or VSODC.
9.4 Status and Diagnostic Codes
Provides descriptions and possible causes for VSODC status and diagnostic codes displayed on the unit.
9.5 Active Protection Fault Details
Detailed explanations of system protection faults and their corresponding error codes and resolutions.
9.6 Electrical Checks Flowchart
A flowchart guiding electrical troubleshooting steps for cooling operation issues.
9.10 Checking Transducers & Temperature Sensors
Procedures for testing and validating the accuracy of system transducers and temperature sensors.