atersa A-150P Installation And User Manual
atersa A-150P Installation And User Manual

atersa A-150P Installation And User Manual

Professional photovoltaic module

Advertisement

MODULE
Installation and User Manual
UNE-EN ISO 9001
UNE-EN ISO 14001
OHSAS 18001
ER-0979/1997
GA-2009/0396
SST-0134/2012
EN
Professional Photovoltaic Module
DISTRIBUTOR
ATERSA VALENCIA
ATERSA MADRID
P.Industria Juan Carlos I
C/ Princesa, 25, 2º-2
28008 Madrid - Spain
Avda. de la Foia, 14
46440 Almussafes
T
el: 915 178 452
Fax: 914 747 467
Valencia - Spain
Tel: 902 545 111
Fax: 902 503 355
Intl. Phone numbers
Tel. +34 961 038 430
Fax.+34 961 038 432
E-Mail: atersa@elecnor.com
(www.atersa.com)
Printed on recycled paper
Last revision 17/01/2017
Dispose of the device at an environmental disposal point when it reaches the end of its useful life
EN-MU-41 (4)-E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the A-150P and is the answer not in the manual?

Questions and answers

Summary of Contents for atersa A-150P

  • Page 1 UNE-EN ISO 9001 UNE-EN ISO 14001 OHSAS 18001 ER-0979/1997 GA-2009/0396 SST-0134/2012 Professional Photovoltaic Module DISTRIBUTOR ATERSA VALENCIA ATERSA MADRID P.Industria Juan Carlos I C/ Princesa, 25, 2º-2 28008 Madrid - Spain Avda. de la Foia, 14 46440 Almussafes el: 915 178 452...
  • Page 2: Table Of Contents

    MODULE Installation and User Manual First, ATERSA and his team thank are grateful for your confidence by purchasing our products for your photovoltaic installation. This manual contains important information about handling, installation and maintenance. Please carefully read and understand this manual before any handling. ATERSA not liable for damages caused due to improper handling, installation or maintenance.
  • Page 3: General Safety

    MODULE Installation and User Manual 1.-GENERAL SAFETY The safety instructions contained in this manual must be strictly followed in order to guarantee the safety of the user and the integrity of the module. Ensure that the installation instructions provided in this document are followed. Guarantees or claims will not be valid if the described process has not been followed The cable pathway must provide mechanical support for the conductors and must provide sufficient protection, in accordance with the Low Voltage Electrotechnical Regulations (REBT).
  • Page 4: Warnings

    The connectors must be protected from dust, sund, wather,..., If the connectors are to remain disconnected in the field. 4.-POSITIONING AND INCLINATION The modules may be installed on plots of land, terraces, roofs and patios. ATERSA provides a series of accessories for installations on façades, windows, balconies, walls and cornices.
  • Page 5: Installation

    IMPORTANT: with the junction box in the lower side. View image The ATERSA modules design allows the correct evacuation of water. They have open edges in the inside tube. 5.- INSTALLATION The modules must be installed on independent fixed structures. The structure must not transmit stress to the modules.
  • Page 6: Hook Fixing System

    5 .1.2.- Hook Fixing System The aluminium frames of ATERSA’s photovoltaic modules have side channels that make it easier to fix the module onto the profiles of the installation. The Hook Fixing System is used to install the modules.This system can be installed on standard structures , “U”...
  • Page 7: Guide Insertion

    MODULE Installation and User Manual Installation Put the first two fixing sets in place, and ensure they are vertically aligned. Fully tighten the Allen screw (6). +1.5 -1.5 Attach the other two fixing sets, aligning them vertically and move them along the rail until they reach the panel.
  • Page 8 To open the spring clip window for the cable, use the appropriate tool (see ATERSA product) or a little screw, to insert vertically into the window as seen in figure 1.View image (8)
  • Page 9: Ground Connection

    MODULE Installation and User Manual For the junction box to maintain its Class II safety standard, the cables must also be Class II. It is not recommended to connect modules in series with a total Voc higher than the system Vmax .(View electrical characteristics). View image (9). Series installation Parallel installation 5.2.2.- Ground connection...
  • Page 10: Installation And Guiding Of Electrical Cables

    6.- MAINTENANCE ATERSA solar modules hardly require any maintenance but you must follow a set of guidelines to ensure good condition. Maintenance work should be carried out by qualified personnel, as it could involve working with dangerously high voltages.
  • Page 11 MODULE Installation and User Manual EN-MU-41 (4)-E...
  • Page 12 MODULE Installation and User Manual EN-MU-41 (4)-E...
  • Page 13 ANNEX Installation and User Manual UNE-EN ISO 9001 UNE-EN ISO 14001 OHSAS 18001 ER-0979/1997 GA-2009/0396 SST-0134/2012 Professional Photovoltaic Module ANNEX Printed on recycled paper Dispose of the device at an environmental disposal point when it reaches the end of its useful life EN-MU-41 (4)-E...
  • Page 14 ANNEX General dimensions Polycrystalline modules 225±25.0 595±25.0 595±25.0 225±25.0 1639 EN-MU-41 (4)-E...
  • Page 15 ANNEX General dimensions Monocrystalline modules 225±25.0 595±25.0 595±25.0 225±25.0 1639 EN-MU-41 (4)-E...
  • Page 16 Always use fastening systems that do not damage the laminate. According to standard IEC 61215:2005 Note: ATERSA reserves the right to modify the product specifications without notice. www.atersa.com For more extensive information about the terms of the warranty and certificates y, please see our website:...

Table of Contents