Table of Contents

Advertisement

Operating manual
ACM
D2/S2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACM S2 and is the answer not in the manual?

Questions and answers

Summarization of Contents

General Information
2. Safety Instructions
Critical safety instructions for users and machines, covering high voltage and proper installation.
2.1. General Safety Instructions
Critical safety instructions for users and machines, covering high voltage and proper installation.
2.2. Intended Use
Defines the inverter's purpose for variable speed control of three-phase motors and system conformity requirements.
2.3. Transport, Storage, Installation
Guidelines on handling, protecting, and installing the inverter, including electrostatic sensitivity.
2.4. Electrical Connection
Detailed instructions for electrical connection, including insulation, discharge times, and circuit-breakers.
2.5. Operating Instructions
Information on inverter restart, motor stopping, and preventing inadvertent restarts for safety.
2.6. Miscellaneous
Notes on responsibility for damage, technical changes, and checking for amendments.
Installation Examples
11.1. Example 1: ACM D2/S2 0.37 kW - 2.2 kW (1 x 230V)
Wiring diagram for a single-phase installation example of ACM D2/S2 inverter.
11.2. Example 2: ACM D2/S2 0.75 kW - 37.0 kW (3 x 400V)
Wiring diagram for a three-phase installation example of ACM D2/S2 inverter.
Installation
12.1. Installation
General guidelines for installing the inverter in a switchgear cabinet and for permanent connection.
12.2. Mains Power Connection
Instructions for connecting the inverter to the mains power supply, emphasizing safety and proper insulation.
12.3. Motor Connection
Guidance on connecting the motor cable to the U, V, W, and PE terminals of the inverter.
12.4. Interference Suppression Measures / EMC
Measures for electromagnetic compatibility, including grounding, shielding, and filtering.
12.5. Mains Back-up Fuses
Details on required upstream fuses for protecting cables and the inverter unit.
12.6. Ventilation
Requirements for maintaining permissible ambient temperature, especially in control cabinets.
12.7. Control Terminals
Detailed description of the functions and connections for each control terminal.
12.8. Power Terminals
Specifications and functions of the power terminals for mains, motor, and braking resistor connections.
Commissioning and Settings
13.1. General Information
Points to observe before commissioning, including voltage, connections, and safety regulations.
13.2. Adaption to Operation
Adapting acceleration/deceleration times and frequency settings for optimal motor performance.
Operating Functions
14.1. General
Overview of ACM D2/S2 inverter operation and pre-programmed motor settings.
14.2. Control Panel
Explanation of the control panel layout and its 4 keys for motor control and parameter programming.
14.3. Display
Details on the alphanumeric display's information, status messages, errors, and selectable language.
14.4. Help - Function and Language - Select
How to access help texts and select the display language for functions and parameters.
14.5. Inverter Status
List of inverter status messages, including OFF, STOP, JOG, and security levels.
14.6. Warnings
Explanation of various warning messages like undervoltage, overload, and ramp limits.
14.7. Operating Error Messages
List of operating error messages (e.g., UNDERVOL, OVERVOLT) with their causes and notes.
14.8. Hardware Error Messages
Troubleshooting hardware errors with causes, remedies, and error codes.
Programming ACM D2/S2
15.1. Program Structure
Overview of the programming structure, showing parameter groups and table organization.
15.2. Program Level TAB1
Configuration of basic inverter parameters, motor voltage, frequency settings, and timing.
15.3. Program Level TAB2
Configuration of analog/digital inputs, BOOST, output voltage, and security features.
15.4. Program Level TAB3
Configuration of outputs, diagnostic utilities, and extended parameters.
Braking Chopper ACM D2/S2
16.1. Braking Chopper 0.37 kW - 1.1 kW (1 x 230V)
Details on the internal dynamic braking chopper for low-power inverters.
16.2. Braking Chopper 0.75 kW - 37.0 kW (3 x 400V)
Information on the control unit for dynamic braking choppers and external resistor connection.
Accessories
17.1. Programming Key
Using the programming key to read, write, and save inverter parameter values.
17.2. Telecomander RC
Remote control capabilities for multiple inverters using the Telecomander RC via RS485.
17.3. DVM - PLUS MP
Multifunctional device for inverter monitoring and access to all functions via RS485.
17.4. ACM - Synchronizer
Functionality of the ACM Synchronizer for motor rotation sensing and speed control.

Table of Contents

Save PDF