OTT Manuals
Data Loggers
netDL 1000
Operating instructions manual
OTT netDL 1000 Operating Instructions Manual
Ip datalogger
Hide thumbs
1
2
Table Of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
page
of
60
Go
/
60
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
Scope of Supply
Order Numbers and Version Code
General Safety Information
About These Operating Instructions
Introduction
Overview of the OTT Netdl IP Datalogger
Overview: Starting up the OTT Netdl Unit
Installing the OTT Netdl Unit
Attaching the OTT Netdl Unit
Device Versions B . . and C . . : -30 °C up to +70 °C
Attaching the Datalogger
Locations of the Screw Terminal Strips and RS-232 Interfaces
Connecting Sensors Having an RS-485 Interface (2-Wire)
Connecting Sensors Having an SDI-12 Interface
Connecting Sensors Having a Pulse Output
Connecting Equipment Having a Status Output
Connecting Sensors Having a Voltage Output
Connecting Sensors Having a Current Output
Connecting the Pt 100 Temperature Sensor
Connecting Sensors Having a Potentiometer (5 Kohms)
Connecting Sensors Having an RS-232 Interface
Connecting Switching Contacts
Connecting 4-20 Ma Outputs
Connecting Status Outputs
Connecting the Power Supply to the OTT Netdl Unit
Connecting the GSM Cellular Radio Antenna and Inserting the SIM Card
Connecting the GSM Cellular Radio Antenna
Connecting External Communication Equipment
Connecting an Ethernet LAN or DSL Router
Connecting to the USB Device Interface
Setting OTT Netdl Operating Parameters
Installing the OTT Data Logger Operating Program
Establishing the PC/OTT Netdl Communication Link (on Site)
Introduction: Setting OTT Netdl Operating Parameters
Operating/Configuring the OTT Netdl Unit on Site
Determining and Displaying Instantaneous Values (Observer Function)
Entering Observer Texts (Extended Observer Function)
Scaling Instantaneous Values/Stored Values (Set Offset)
Displaying/Setting Date and Time
Entering Manual Values into a Manual Sensor
Displaying Information on Transmissions over the Internet
Displaying Information on Connections
Displaying System Information
Starting the Voice Announcer (on Site)
LED Indicators
Reading out Measured Data on Site
Updating the OTT Netdl Firmware
Overview: Alarm and Action Management
Protecting the OTT Netdl Unit Using a Password
Deleting the Data Memory
Setting Date and Time
Creating and Printing the Terminal Connection Diagram
Creating and Printing a Device View
OTT-SDI Transparent Mode
Voice Announcer Functionality Overview
Error Messages
Internal Error Messages
External Error Messages
Sensor Error Messages
Processing Module Error Messages
Maintenance
Repair
Note on the Disposal of Old Units
Technical Data
Appendix A: OTT Netdl 500 /OTT Netdl 1000 Declaration of Conformity
Advertisement
Quick Links
1
Overview of the Ott Netdl Ip Datalogger
2
Reading out Measured Data on Site
Download this manual
Operating instructions
IP Datalogger
OTT netDL 500
OTT netDL 1000
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the netDL 1000 and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for OTT netDL 1000
Data Loggers OTT netDL 500 Operating Instructions Manual
Ip datalogger (60 pages)
Data Loggers OTT HydroMet SensorLink 1000 Operating Instructions Manual
Compact datalogger (56 pages)
Data Loggers OTT ecoLog 1000 Operating Instructions Manual
Groundwater datalogger (68 pages)
Data Loggers OTT ecoLog 800 Operating Instructions Manual
Groundwater datalogger (56 pages)
Data Loggers OTT Orpheus Mini Operating Instructions Manual
Groundwater datalogger (44 pages)
Data Loggers OTT CTD Operating Instructions Manual
Ground water data logger (44 pages)
Summarization of Contents
Scope of Supply and Ordering Information
OTT netDL 500 / OTT netDL 1000 Components
Details the standard components and optional GSM modem for both models.
Expansions and Ordering Codes
Lists available expansion cards and version code structure for the datalogger.
Accessories for OTT netDL Units
Cables and Antennas
Describes connection cables and GSM antennas for the datalogger.
General Safety Information
Key Safety Precautions
Lists critical warnings for installation and operation, including moisture, temperature, and electrical safety.
About These Operating Instructions
Supported Software Versions
Identifies the supported firmware and operating program versions.
Introduction to the OTT netDL Datalogger
Datalogger Overview and Features
Provides a general overview of the IP-enabled datalogger and its models and features.
Overview of the OTT netDL IP Datalogger Features
Sensor Input and Communication Interfaces
Lists supported sensor interfaces like RS-485, SDI-12, and communication interfaces such as RS-232, USB, and Ethernet.
Communication Protocols and Outputs
Lists supported protocols like Modbus, SDI-12, FTP and describes available outputs.
Measured Value Processing Capabilities
Outlines processing capabilities like scaling, mean calculation, and filter functions.
Starting Up the OTT netDL Unit
Step-by-Step Initialization Guide
Outlines the sequential steps for initializing the OTT netDL unit.
Installing the OTT netDL Unit
Mounting the Datalogger
Explains how to mount the datalogger onto a top hat rail and its requirements.
Terminal Strip and RS-232 Interface Locations
Power, Switching Contacts, and Sensor Connections
Details connections for power, switching contacts, and various sensor types.
4-20 mA Outputs and Status Outputs
Illustrates connections for 4-20 mA outputs and status outputs.
RS-232 Interface Pin Assignments
Shows pin assignments for COM 1 and COM 2 serial interfaces.
Connecting RS-485 Interface Sensors
RS-485 Sensor Wiring and SLD Connection
Explains wiring for RS-485 sensors and connecting the OTT SLD unit.
Connecting SDI-12 Interface Sensors
SDI-12 Sensor Wiring
Shows how to connect SDI-12 sensors to terminal strip C.
Connecting Pulse Output Sensors
Pulse Input Connections
Illustrates connecting pulse output sensors to terminal strips D and E.
Connecting Status Output Equipment
Status Output Wiring
Shows connections for equipment with status outputs.
Connecting Voltage Output Sensors
Voltage Output Wiring
Details wiring for voltage output sensors to terminal strips G-K/G-M.
Connecting Current Output Sensors
Current Output Wiring
Explains connections for 4-20 mA current output sensors.
Connecting the Pt 100 Temperature Sensor
Pt 100 Sensor Wiring
Shows how to connect a Pt 100 temperature sensor.
Connecting Potentiometer Sensors (5 kOhms)
Potentiometer Sensor Wiring
Illustrates wiring for 5 kOhm potentiometer sensors.
Connecting RS-232 Interface Sensors
RS-232 Sensor Wiring
Details connecting sensors via RS-232 interface using connector G-H, J-K, L-M.
Connecting Switching Contacts
Switching Contact Wiring
Shows how to connect switching contacts to terminal strip N.
Connecting 4-20 mA Outputs
4-20 mA Output Wiring Schematics
Explains connection schematics for 4-20 mA outputs, both internal and external.
Connecting Status Outputs
Status Output Wiring
Details connecting status outputs using terminal strip G-K/G-M.
Connecting the Power Supply
Power Supply Wiring
Illustrates connecting the power supply to terminal strip N and PCU 12.
GSM Antenna and SIM Card Installation
GSM Antenna and SIM Card Setup
Guides on connecting the GSM antenna and inserting the SIM card.
Connecting External Communication Equipment
Modem and Satellite Unit Connections
Explains connecting serial modems, GSM modems, or satellite units.
Connecting Ethernet LAN or DSL Router
Ethernet/DSL Router Connection
Details how to connect the unit to an Ethernet LAN or DSL router.
Connecting the USB Device Interface
USB PC Communication Setup
Guides on establishing a communication link via USB to a PC.
Setting OTT netDL Operating Parameters
Installing the Data Logger Operating Program
Steps for installing the PC software required for configuration.
Establishing PC/OTT netDL Communication Link
Instructions for setting up communication via data transfer or USB cable.
Operating and Configuring the OTT netDL Unit On Site
Jog Shuttle Functions and LCD Symbols
Lists functions accessible via the jog shuttle and explains LCD symbols.
Displaying Instantaneous Values (Observer Function)
How to view real-time sensor readings using the Observer function.
Entering Manual Check Values for Measurements
How to input manual check values for measurements.
Entering Observer Texts
Station and Channel Text Entry
Procedure for inputting station-specific and channel-specific text entries.
Scaling Instantaneous Values (Set Offset)
Adjusting Measured Values (Scaling)
Steps to scale or adjust measured values using the offset function.
Displaying and Setting Date and Time
Configuring Unit Date and Time
How to set or display the internal clock of the datalogger.
Entering Manual Values into a Manual Sensor
Manual Sensor Data Input
Procedure for manually entering sensor data.
Displaying Information on Internet Transmissions
Internet Transmission Status Monitoring
How to view the status of data transmissions over the internet.
Displaying Information on Connections
Modem and LAN Connection Status
Displays status and details for modem and Ethernet/LAN connections.
Displaying System Information
Event Log and Device Version Details
How to view recorded events and system hardware/software revision details.
Starting the Voice Announcer On Site
Activating the On-Site Voice Announcer
Steps to activate the voice announcer feature on site.
LED Indicators
Logger, Modem, and Ethernet LEDs
Explains the status indicated by the Logger, Modem, and Ethernet interface LEDs.
Reading Out Measured Data On Site
Data Retrieval via RS-232, USB, and Modem
Instructions for retrieving data using PC software via different connection methods.
Updating the OTT netDL Firmware
Firmware Update Procedure
Step-by-step guide for updating the datalogger's operating system.
Alarm and Action Management
Alarm Triggers and Available Actions
Conditions that trigger alarms and the types of actions/alarms the unit can generate.
Protecting the OTT netDL Unit with a Password
Securing and Unlocking Unit Operation
How to lock the unit with a password and the procedure to unlock it.
Setting Date and Time
Configuring Unit Date and Time
Steps to set or display the internal clock of the datalogger.
Deleting the Data Memory
Erasing Stored Measurement Data
Instructions on how to clear the stored measurement data from the unit.
Creating and Printing Terminal Connection Diagrams
Generating and Printing Connection Diagrams
How to create and print a terminal connection diagram using the software.
Creating and Printing Device Views
Generating and Printing Unit Views
Steps to create and print a visual representation of the unit's front/rear views.
OTT-SDI Transparent Mode
Direct Sensor Communication via Terminal Mode
How to communicate directly with SDI-12 sensors via terminal emulation.
Launching the OTT SDI-12 Interface Software
Guide to launching and using the specific software for SDI-12 sensors.
Voice Announcer Functionality Overview
Voice Announcer Usage Methods
Describes the different ways the voice announcer can be utilized.
Error Messages
Internal, External, and Sensor Error Codes
Lists and explains internal, external, and sensor error codes displayed by the unit and sensors.
Specific Sensor and Module Error Messages
Lists error codes for Parsivel, SDI, RS-232 sensors and processing modules.
Maintenance
Backup Battery Replacement Recommendation
Recommendation for periodic replacement of the real-time clock backup battery.
Repair
Contacting the OTT Repair Center
Information on how to contact the OTT repair center for faulty units.
Disposal of Used Units
Proper Disposal Guidelines
Instructions for proper disposal of the unit in EU and other countries.
Technical Data
Power, Supply, and Clock Specifications
Details voltage, power usage, and clock specifications.
Communication Interfaces and Protocols
Technical specifications for communication interfaces and supported protocols.
Input/Output and Sensor Specifications
Technical parameters for various inputs, outputs, and sensors.
Analog, RS-232, RS-485, and SDI-12 Interface Details
Detailed specifications for analog, RS-232, RS-485, and SDI-12 interfaces.
Appendix A: Declaration of Conformity
Product Compliance Information
Official declaration of compliance with relevant standards and regulations.
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the netDL 1000 and is the answer not in the manual?
Questions and answers