Samsung AE090JXYDEH/EU Installation Manual

Samsung AE090JXYDEH/EU Installation Manual

Air source heat pump

Advertisement

SAMSUNG EHS
Air Source Heat Pump Installation Guide
AE050JXYDEH/EU
AE090JXYDEH/EU
AE120JXYDEH/EU
AE140JXYDEH/EU
AE160JXYDEH/EU
Date of Issue: 30/01/17

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AE090JXYDEH/EU and is the answer not in the manual?

Questions and answers

Summarization of Contents

Outdoor Unit Installation and Dimensions
MIM Box Installation and Components
Information on the indoor control box, its installation, and included components.
Flexible Hoses for Heat Pump Connections
Mounting Feet Installation
Guidance on correctly installing the mounting feet for the heat pump unit.
System Pressure Management Components
Details on expansion vessels, pressure relief valves, and filling loops for heating systems.
Heat Pump System Circulation Pump Requirements
Specifies minimum flow rates and static resistance requirements for the circulation pump.
Flow Monitoring and Control Components
Information on the flow switch and flow meter for ensuring correct system operation and preventing faults.
Diverter Valve Functionality
System Protection: Dirt Filter and Filter Ball
Details the importance of dirt filters and filter balls for preventing blockages and maintaining warranty.
Glycol Antifreeze for Heat Pumps
Guidance on using glycol (Tyfocor L) for frost protection in outdoor heat pump installations.
Hydraulic Separator Benefits
Explains how hydraulic separators improve system balancing and avoid short cycling.
Inverter Technology in Heat Pumps
Describes how inverter technology allows variable output and eliminates buffer vessel need.
Heat Pump Defrost Cycle Operation
Explains the defrost mode operation to prevent ice build-up on outdoor unit coils.
Ensuring Balanced System Flow
Micro Bore Pipe System Considerations
Addresses potential noise issues with microbore pipework and the use of hydraulic separators.
Hot Water Cylinder Requirements for Heat Pumps
Specifies requirements for DHW cylinders, including coil size, person per day, and reheat time.
Fast Connect System Overview
Fast Connect System Operation
Details how the Fast Connect system controls hot water and heating zones using sensors and thermostats.
Heating and Hot Water System Configurations
Reduced Glycol System Setup
Explains how to reduce glycol usage via a plate heat exchanger for heating and hot water systems.
Heating & Hot Water System Operation
Describes the operation of heating and hot water systems, including cylinder control and zone management.
Multi Fuels System Integration
Multi Fuels System Operation
Explains the operational logic for Multi Fuels systems, managing heat pump and auxiliary sources.
Multiple Heat Pump System Design
Multiple Heat Pump System Operation
Describes how multiple heat pumps operate simultaneously to provide heating and hot water.
Combi Hybrid System Overview
Combi Hybrid System Operation
Explains the operation of combi hybrid systems, prioritizing boiler for DHW and heat pump for heating.
Heating Only Hybrid System Configuration
Heating Only Hybrid System Operation
Explains how heating only hybrid systems manage heat pump and boiler operation based on ambient temperature.
Inclusions: Heat Pump Unit Contents
Two Port Valve Connections
Explains wiring for DHW and heating two-port valves, including terminal assignments.
Multi-Zone Heating System Wiring
Details how to wire multi-zone heating systems, including stat and zone valve connections.
Circulation Pump Wiring
Specifies wiring for the circulation pump to the control board, including power limits.
Heat Pump System Initial Start-Up
Cylinder Immersion Heater Setup
Instructions for setting the cylinder immersion heater temperature to ensure legionella protection.
Powering Up the Heat Pump System
Guidance on the correct sequence for applying power to the indoor and outdoor units.
Controller Clock and Backlight Settings
Procedure for adjusting the date, time, and backlight settings on the heat pump controller.
Cylinder Timer Programming
Solar Input Integration with Hot Water
Advice on optimizing cylinder heating timers when using solar input for hot water.
Flow Rate Checks for Heat Pump Operation
Heating Mode Flow Rate Testing
Procedure to test and verify correct flow rates when the unit is operating in heating mode.
Bypass Valve Setup for Flow Testing
Instructions for setting up a bypass valve when no hydraulic separator is present for flow testing.
Initiating Heat Pump in Hot Water Mode
Hot Water Mode System Test
Steps to test system performance and temperature gain during hot water operation.
Troubleshooting Insufficient Hot Water
Diagnosing and resolving issues related to low hot water temperature or supply.
System Handover to Homeowner
Weather Compensation Explained
Explains how weather compensation adjusts flow temperature based on outdoor ambient temperature.
Efficient Heat Pump Operation Tips
Advice on maintaining constant temperatures and adjusting settings for energy efficiency.
General Heat Pump System Advice
Hot Water Priority and Legionella Cycle
Details hot water priority, cylinder temperature control, and the legionella cycle.
Monobloc Heat Pump Maintenance Procedures
Routine Maintenance Procedure Steps
Specific steps for inspecting the unit, checking glycol concentration, and testing system operation.
Hot Water Cylinder Maintenance Checks
Checks for the hot water cylinder, including immersion connections, sensor, and flow rate verification.
Troubleshooting Heat Pump Problems and Faults
Heating System Operational Issues
Addresses high running costs, stat connection errors, and ensuring the heat pump turns off correctly.
Hot Water System Operational Issues
Troubleshooting low hot water, tank stat positioning, and immersion heater activation.
Controller Communication Faults
Error Code 00: Outdoor Unit Communication Error
Troubleshooting error code 00, indicating a communication issue between indoor and outdoor units.
Error Code 01: Controller Power Without Outdoor Unit Connection
Diagnosing error code 01, where the controller has power but is not connected to the outdoor unit.
E911 Fault: Insufficient Water Flow
Cold Weather Start-Up Protection
Explains cold weather protection functions, including low fluid temperature and pump operation.
E904 Error: Cylinder Stat Issue
Troubleshooting E904 error codes related to cylinder stat connection or function.

Table of Contents

Save PDF