Advertisement

M-Fog 1000,
M-Fog 1500,
M-Fog 2500
fog machine
user manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the M-Fog 2500 and is the answer not in the manual?

Questions and answers

Summarization of Contents

General Information
Further Information
Details on downloading the manual, keyword search, online guides, and personal consultation.
Notational Conventions
Explanation of letterings, italics, square brackets, and cross-references used in the manual.
Symbols and Signal Words
Overview of the meaning of symbols and signal words used throughout the manual.
Safety Instructions
Intended Use
Specifies that the device is for producing artificial fog and must be used as described in the manual.
Child Safety Warnings
Ensures plastic bags, small parts are kept away from children to prevent choking hazards.
Electrical Safety Precautions
Warns about high voltages inside the unit and the risks of modifying the mains cable or plug.
Burn Hazard Warnings
Alerts to risks from flammable liquids and the hot fog nozzle, advising safe distances.
Fluid Handling and Environmental Safety
Addresses slipping hazards from condensation and health risks from improper fog fluid handling.
Operational and Fire Safety
Warns about respiratory issues from non-approved fluids and fire risks near heat sources or vents.
Operating Conditions and Power Supply Safety
Advises on indoor use, avoiding liquids/moisture, and proper power connection and unplugging.
Features
Device Applications
Suitable for use in clubs, bars, discotheques, stages, and for fire drills.
Special Device Features
Highlights DMX control, removable control panel, and large liquid container.
Installation
Unpacking and Packaging
Instructions for unpacking, checking for damage, and using original or suitable packaging for transport/storage.
Mounting Options
Describes standing or hanging installation, requiring a solid surface or truss attachment.
Work Platform Safety
Emphasizes working from a stable platform and blocking access under the work area during installation or maintenance.
Installation Safety
Ensures installation complies with standards, uses secondary safety attachments, and checks load-bearing capacity.
Standing Installation
Details placing the unit on a flat surface, tilt angle limits, and required clearance.
Flying Operation
Explains how to attach the unit in flying operation using mounting and safety cables through safety eyes.
Starting Up
Connection Guidelines
Establish all connections while the unit is switched off using short, high-quality cables.
DMX Cable Recommendation
Advises using dedicated DMX cables, not microphone cables, for error-free operation.
DMX Mode Connections
Details connecting the DMX input to a controller or other device and terminating the last output with a resistor.
Connections and Operating Elements
Device Overview
Diagram showing numbered connections and operating elements on the fog machine.
Element Identification (1-7)
Lists and describes elements 1-7: Fog nozzle, fluid container, handle, safety eyes, main switch, DMX input/output.
Element Identification (8-13)
Lists and describes elements 8-13: Rotary controls for interval/duration/volume, thumb screws, on/off switch, DIP switch.
Operating
Filling the Unit with Fog Fluid
Instructions for filling the fog fluid container, emphasizing using approved fluids and avoiding spills.
Turning the Unit On
Details connecting to power, using the main switch, and indicators for power and ready status.
Turning the Unit Off
Procedure for turning off the unit and safety advice for transport with an empty fluid container.
Time-Controlled Operation
Explains detaching the control panel, setting interval and duration using rotary controls, and adjusting fog intensity.
DMX Mode Operation
Describes setting the DMX address using DIP switches with examples of address sets.
DMX Channel Allocation
Details the functions assigned to DMX channels for blast volume and interval between fog blasts.
DMX Channel Functions
Details the functions assigned to DMX channels for fog blast duration.
Technical Specifications
M-Fog 1000 Specifications
Lists heater power, fog output, fluid capacity, warm-up time, voltage, fuse, dimensions, and weight.
M-Fog 1500 Specifications
Details heater power, fog output, fluid capacity, warm-up time, voltage, fuse, dimensions, and weight.
M-Fog 2500 Specifications
Provides heater power, fog output, fluid capacity, warm-up time, voltage, fuse, dimensions, and weight.
Troubleshooting
Unit Not Working
Check mains connection and fuse if the unit does not work.
No DMX Controller Response
Troubleshooting steps for no response to DMX controller, including cable checks, address settings, and interference.
No Fog Output
Remedies for no fog output include checking fluid level and hose flow.
Contacting Service
Instructions to contact the service center if troubleshooting procedures do not resolve the issue.
Cleaning
Cleaning Procedure
Steps for cleaning the appliance, including turning it off, using cleaning fluid, and running the unit.
Rinsing Pipes
Details switching to continuous operation to release fog for 20 seconds to rinse the pipes.
Protecting the Environment
Packaging Disposal
Guidance on recycling environmentally friendly packaging materials and proper disposal of plastic bags.
Old Device Disposal
Advises on disposing of the device according to WEEE directive via approved firms or local facilities.