Download Print this page

Panamax M5400-EX Specifications page 2

Datasheet
Hide thumbs Also See for M5400-EX:

Advertisement

MAX
5400-EX REAR PANEL FEATURES
®
Main Circuit
Outlet Banks 3 & 4
Breaker
Two switched outlets per bank. ON/OFF status is controlled by the
front panel Power Button or the DC Trigger input. They will turn on
Automatically opens
immediately and turn off after 10 seconds. EMI/RFI noise filtration
when the current
is provided by the four stage balanced Pi filter. Banks 3 and 4 are
load is greater than
noise isolated from each other as well as all other outlet banks
15 Amps.
Main Power
Outlet Bank 5
Must be plugged
Two switched, high current outlets controlled by
into
a
properly
the front panel Power Button or the DC Trigger
wired & grounded
input. Bank 5 has a 5 second turn on delay and
3-wire outlet
turns off immediately. The High Current outlets
provide power from a low impedance noise filtra-
tion circuit that does not limit the current to your
Ground Lug
equipment. Its output is noise isolated from all of
Provides a common grounding
the other outlet banks.
point for equipment with separate
ground leads.
MAX
5400-EX SPECIFICATIONS
®
AC Power
Line Voltage:____________________________________________________120V, 60Hz
Total Current Capacity:
_______________________________________________15 A
UL1449 Suppression Rating:____________________________________________330V
Protection Modes:______________________________________________L-N, L-G, N-G
Initial Clamping Level:_________________________________________________200V
Energy Dissipation:______________________________________________1815 Joules
Peak Impulse Current:___________________________________________73,000 Amps
Catastrophic Surge Circuit:_______________________________________________Yes
Thermal Fusing:_______________________________________________________Yes
Over-voltage shutoff:__________________________________________142 VAC ±5 VAC
Under-voltage shutoff:_________________________________________90 VAC ± 2 VAC
EMI/RFI Noise Filtration
Banks 1 - 4:________________________________________100 db, 100 KHz – 2 MHz
Bank 5, High Current Outlets:____________________________60 db, 100 KHz – 2 MHz
Common Mode (all banks)______________________________60 db, 100 KHz - 2 MHz
DC Trigger Input
Jacks:_______________________________________________3.5mm (1/8") mini-plug
Voltage and Polarity:___________________________________3 - 24V DC, bidirectional
Current Requirement:_________________________________4.6 mA @3V, 58 mA @24V
DC Trigger Output
Voltage:____________________________________________________________<15V
Current:_________________________________________________________<500 mA
Short-circuit protection:_________________________________________________Yes
Delay on output:_________________________________________________10 seconds
UPC's, QUANTITIES, WEIGHTS & MEASUREMENTS FOR ORDERING & SHIPPING
MODEL M5400-EX
Dimensions
Weight
17" x 12.75" x 3.5"
19 lbs
4.1" H with feet
OPTIONAL SILVER BEZEL
SILVER BEZEL
PRODUCT
Model #
Dimensions
BEZ5400-EXS
17" W x 0.625" D x 3.5" H
The Power Specialists Since 1975
1690 Corporate Circle, Petaluma, CA 94954
®
© 2005 Panamax. Panamax, MAX and the Panamax logo are registered US trademarks of Panamax. Protect or Disconnect and AVM are trademarks of Panamax. SIDACtor is a registered US trademark of Teccor Electronics, Inc.
Outlet Banks 1 & 2
Two always on outlets per bank. Power will only be
turned off under a fault condition. (See specifications
for over-voltage and under-voltage thresholds)
Power for each bank is cleaned by a four-stage bal-
.
anced Pi filter. Banks 1 and 2 are noise isolated from
each other as well as all other outlet banks.
Voltage Sense
Trigger Input
3.5mm (1/8") Mini-Plug jack.
Connect to a remote trigger
device that uses a DC output
to trigger a startup/shutdown
sequence. This bypasses the
front panel power switch.
Specifications subject to change due to product upgrades and improvements.
UNIT CARTON
Dimensions
Weight
23.75" x 19.25" x 9.5"
22.5 Lbs
Weight
Dimensions
14 Oz
18" x 4" x 1"
Voltage Sense
Trigger Output
3.5mm (1/8") Mini-Plug jack.
Connecting a trigger wire to the
Voltage Sense Output jack will
allow the input signal to pass
through the MAX® 5400-EX to
control the startup/shutdown of
an additional device.
LAN Circuit
Clamping Level:____________________________________________________8V ± 2V
Jacks:_____________________________________________________________RJ-45
Wires Protected:_______________________________________4-Wires, Pins 1, 2, 3 & 6
Telephone Circuit
Fuseless/Auto-resetting:_________________________________________________Yes
Clamping Level:______________________________________________________260V
Capacitance:__________________________________________________30pf (approx.)
Suppression Modes:____________________________________Metallic & Longitudinal
Jacks:_____________________________________________________________RJ-11
Wires Protected:___________________________________________2-Wire, Pins 4 & 5
Satellite TV Circuit
Bidirectional:__________________________________________________________Yes
Shielded:_____________________________________________________________Yes
Clamping Level:_______________________________________________________27V
Attenuation:______________________________________< 1db from 950MHz-2.05GHz
Connections:__________________________________________Female "F", Gold Plated
Cable TV Circuit
Bidirectional:__________________________________________________________Yes
Shielded:_____________________________________________________________Yes
Clamping Level:_______________________________________________________1.4V
Attenuation:________________________________________< 1db from 5MHz- 950MHz
Connections:__________________________________________Female "F", Gold Plated
UPC
Qty
0 50616 00787 0
1
UNIT CARTON
Weight
UPC
17.5 Oz
0 50616 00793 1
800-472-5555 or 707-283-5900
Satellite TV
Coax Jacks
Bidirectional protection
circuit optimized for
satellite TV signal lines.
High Current Outlets
LAN Jacks
Delay Switch For
Protection circuits
for 10/100 baseT
Outlet Bank 5
Ethernet lines.
Allows the outlet bank to be set
as "Always ON" or with a 5
second turn-on delay
Switched Outlets Delay Switch For Outlet Banks 3 & 4
Allows the outlet banks to be set as "Always ON" or with a 10 second turn-off delay
MASTER CARTON
Dimensions
Weight
Same as
22.5 Lbs
Unit Carton
MASTER CARTON
Qty
Dimensions
Weight
N/A
N/A
N/A
Fax - 707-283-5901
Cable TV Coax Jacks
Bidirectional protection circuit opti-
mized for cable TV, off-air antennas
and cable modem signal lines.
Phone Jacks
Protection circuits for stan-
dard telephone or pay-per-
view lines. Phone circuit is
auto-resetting.
< 2.4db @ 2.2GHz
UPC
5 00 50616 00787 5
UPC
N/A
www.panamax.com

Advertisement

loading

This manual is also suitable for:

Max 5400-ex