Qualified Installer and Service Person Definitions
Installer and Service Person Qualifications
Details the qualifications and knowledge required for qualified installers and service personnel.
Protective Gear and Unit Warnings
Air Conditioner Unit Warning Indications
Explains warning symbols and their meanings on the air conditioner unit for safe operation.
Safety Precautions
General Safety Guidelines
Covers essential safety rules for installation, handling, and general operation.
Installation Location Selection
Guidelines for choosing an appropriate and safe installation site for the unit.
Unit Installation Procedures
Instructions and safety measures for the physical installation of the air conditioner.
Refrigerant Piping Safety
Safety considerations and warnings related to refrigerant piping installation and handling.
Electrical Wiring Safety
Critical safety instructions for electrical wiring to prevent shocks and fires.
Unit Relocation
Safe Relocation Procedures and Cautions
Safe practices and precautions for relocating the air conditioner unit.
Accessory Parts and New Refrigerant Installation
Included Accessory Parts List
Lists all parts included with the air conditioner, such as manuals and pipes.
New Refrigerant Air Conditioner Installation
Details on installing the air conditioner with new R410A refrigerant.
Required Tools and Handling Cautions
Specifies necessary tools and precautions for handling the new refrigerant system.
Installation Site Selection
Installation Space Requirements
Defines the necessary space clearances for installation, maintenance, and airflow.
Outdoor Unit Handling and Weight
Weight Center and Dimensions
Information on the unit's weight, center of gravity, and dimensional specifications.
Outdoor Unit Installation
Installation Requirements and Snowfall Area Considerations
General installation requirements and specific advice for areas with snowfall.
Refrigerant Piping Connections
Suction Gas Pipe Connections
Instructions for connecting the suction gas pipes to the outdoor unit.
Discharge Gas and Liquid Pipe Connections
Guidance on connecting discharge gas and liquid pipes.
Refrigerant Piping Installation Details
Connecting Refrigerant Pipes
Details the process of connecting refrigerant pipes, including requirements.
Gas Side Valve Connection Methods
Illustrates how to connect valves on the gas side of the piping.
Copper Pipe Machining and Sizing
Flare Machining Dimensions
Specifies dimensions and margins for flaring copper pipes.
Brazed Pipe Coupling Sizes
Details the required sizes for brazed pipe couplings.
Pipe Size Selection
Indoor and Outdoor Unit Capacity Codes
Explains capacity coding for indoor and outdoor units for pipe sizing.
Refrigerant Piping Lengths and Height Differences
System Connection Restrictions
Outlines limits for system configuration and unit combinations.
Flow Selector Unit Connection Limits
Specifies limits for connecting indoor units to a flow selector unit.
Installation Cautions for Piping
Provides important installation advice and cautions related to piping.
Airtightness Testing
Leak Detection Procedures
Describes methods and steps for performing an airtightness test to detect leaks.
Vacuum Drying and Refrigerant Charging
Vacuum Drying Procedure
Details the process of vacuum drying the refrigerant system before charging.
Calculating Additional Refrigerant Charge
Explains how to calculate the extra refrigerant needed for piping length.
Valve Operations and Refrigerant Charging
Full Valve Opening Procedures
Instructions on how to fully open balance, liquid, discharge, and suction side valves.
Labeling and Pipe Finishing
F-GAS Label Requirements
Instructions for applying the F-GAS label and recording refrigerant information.
Pipe Heat Insulation and Finishing
Covers pipe heat insulation and sealing of connections after piping work.
Pipe Holding Bracket Installation
Guidance on installing pipe holding brackets at specified intervals.
Electrical Wiring
Power Wiring Selection
Guidance on selecting appropriate power wiring based on unit specifications.
Power Supply Specifications
Details the required power supply voltage, frequency, and protection ratings.
Communication Wiring
Communication Wiring Design Overview
Provides a summary and design considerations for communication wiring systems.
Wire Connections
Power Supply Wire Connection
Step-by-step instructions for connecting power supply wires to the unit.
Wiring Terminals and Harmonic Current
Communication Wire Connection Details
Specifies screw sizes, tightening torques, and connection points for communication wires.
Harmonic Current Regulation Compliance
Information on equipment compliance with harmonic current standards (IEC 61000-3-12).
Unit Address Setting
Automatic Address Setting Procedure
Step-by-step guide for automatically setting unit addresses on the system.
Unit Address Setting Procedures
Manual Address Setting Procedure 2
Details a second procedure for manually setting unit addresses via interface board switches.
System Configuration and Addressing
Central Control Address Setting Example
Illustrates address setting for systems with central control, including relay connector use.
Manual Address Setting via Remote Controller
Setting Indoor Unit Addresses Manually
Instructions for manually setting indoor unit addresses using a wired remote controller.
Indoor Unit Address Confirmation
Confirming Unit Positions and Addresses
How to check indoor unit addresses and their positions using the remote controller.
Changing Indoor Unit Addresses
Procedure for modifying indoor unit addresses using the remote controller.
Manual Address Adjustment and Reset
Resetting Unit Addresses to Factory Default
Methods to reset unit addresses back to their factory default settings.
Flow Selector Unit Setup
Cautions for Flow Selector Unit Connection
Important considerations and warnings for connecting the Flow Selector unit.
Setting the CODE No. for Flow Selector
Guide to setting the CODE No. for the Flow Selector unit for proper operation.
Cooling Only Indoor Unit Setup
Setting Indoor Units for Cooling Only Operation
Procedure to configure indoor units specifically for cooling-only mode.
Test Run Procedures
Pre-Test Run Checks
Essential checks to perform before initiating a test run of the air conditioner.
Test Run Using Remote Controller
Steps for conducting a test run using the wired remote controller.
Test Run Using Outdoor Unit Interface Board
Instructions for performing a test run via the outdoor unit's interface P.C. board.
Troubleshooting and Error Codes
7-Segment Display and Check Code Interpretation
Guide to interpreting 7-segment display codes for troubleshooting unit errors.
Machine Card and Logbook
Machine Card Information
Details on filling out and using the machine card for unit history.
Logbook Maintenance Records
Instructions for maintaining the logbook with maintenance and repair records.
Refrigerant Leakage Warnings
Refrigerant Concentration Limit Check
Guidance on checking refrigerant concentration limits and necessary safety measures.