Installation and Operational Guidelines
Installation Site Considerations
Guidelines for choosing a suitable installation location for the air conditioner, considering environmental factors.
Neighbourhood Nuisance Prevention
Advice on selecting an installation spot to avoid disturbing neighbours with operation noise or discharged air.
Electrical Work and System Relocation
Information on dedicated power circuits and the need for professional help for system relocation.
Unit Component Identification
Indoor Unit Parts Description
Identification and description of the parts of the indoor unit of the air conditioner.
Outdoor Unit Component Details
Identification and description of the parts of the outdoor unit of the air conditioner.
Remote Controller Layout and Functions
Detailed breakdown and explanation of the Daikin remote controller buttons and display.
Initial Operation Setup
Remote Controller Battery Installation Guide
Step-by-step guide on how to insert batteries into the remote controller.
Remote Controller Holder Mounting Instructions
Instructions on how to fix the remote controller holder onto a wall or pillar.
Clock Setting and Power Activation
Procedures for setting the unit's clock and turning on the main breaker.
Air Conditioner Operating Modes
Mode Selection and Temperature Adjustment
How to start, stop, and change the temperature settings for various operation modes.
Airflow Rate Adjustment
Instructions on how to adjust the fan speed settings for different operating modes.
Airflow Direction Control
Horizontal Flap Adjustment
Guide to adjust the horizontal air louvers (flaps) for desired airflow direction.
Vertical Louver Adjustment
Guide to adjust the vertical air louvers for desired airflow direction.
3-D and Comfort Airflow Modes
Explanation of starting, canceling, and the effects of 3-D and Comfort Airflow modes.
Intelligent Operation Features
Comfort Airflow Mode Guide
How to activate and deactivate the Comfort Airflow mode for pleasant air circulation.
Intelligent Eye Sensor Activation
Instructions for using the Intelligent Eye sensor for energy saving and automatic operation.
Advanced Intelligent Eye Settings
Intelligent Eye Energy Saving Function
Details on how the Intelligent Eye sensor contributes to energy saving operations.
Combining Comfort Airflow and Intelligent Eye
How to use Comfort Airflow and Intelligent Eye functions simultaneously.
Special Operation Modes
Powerful Operation Guide
How to activate and deactivate the Powerful mode for maximum cooling/heating effect.
Outdoor Unit Quiet Operation
Instructions for reducing outdoor unit noise, ideal for nighttime use.
ECONO Operation Mode
How to enable ECONO mode for efficient operation by limiting power consumption.
Timer Functions and Multi-System Operation
Off Timer Setting Procedure
Guide to setting the timer to automatically switch off the air conditioner.
On Timer and Combined Timer Settings
How to set the ON timer and combine ON and OFF timers for flexible operation.
Multi-System Operation Notes
Information specific to operating multiple indoor units connected to a single outdoor unit.
Priority Room Setting Management
Operation Mode Priority in Multi Systems
How operation modes are prioritized when multiple indoor units are connected.
Priority Room Setting Examples
Examples illustrating how priority room settings affect operation modes and features.
Unit Cleaning and Filter Maintenance
Indoor and Outdoor Unit Cleaning
Instructions for cleaning the indoor and outdoor units of the air conditioner.
Front Panel Cleaning and Attachment
Detailed steps for opening, cleaning, and reattaching the front panel.
Air Filter Cleaning Procedure
How to clean and maintain the standard air filters for optimal performance.
Photocatalytic Filter Care and Replacement
Instructions for cleaning and replacing the Titanium Apatite Photocatalytic Air-Purifying Filter.
System Checks and Long-Term Storage
Regular System Health Checks
Guide to performing checks on the unit's base, fittings, and air inlets/outlets.
Preparation for Extended Idle Periods
Steps to prepare the unit for extended periods of non-use, including drying and battery removal.
Troubleshooting Common Operational Issues
Operation Start-up Delays and Airflow Issues
Reasons for delayed operation start, hot air flow, and mist formation.
Outdoor Unit Phenomena and Odor Causes
Explanations for outdoor unit steam, fan rotation without operation, and indoor unit odors.
Advanced Troubleshooting and Checks
Air Conditioner Non-Operation or Poor Effect Checks
Checklist for diagnosing why the air conditioner might not operate or has poor cooling/heating.
Sudden Stops and Abnormal Functioning Diagnosis
Guidance on troubleshooting sudden operation stops and abnormal functioning, including multi-system considerations.
Service and Safety Warnings
Critical Symptoms Requiring Service
List of critical symptoms that require immediate consultation with a service shop.
Disposal, Maintenance, and Refrigerant Information
Guidelines for proper product disposal, battery handling, and periodic professional maintenance.
Remote Controller Fault Diagnosis
Activating the Fault Diagnosis Mode
How to activate the fault diagnosis mode using the remote controller.
Interpreting Error Code Displays
Explanations of various error codes displayed on the unit during fault diagnosis.
Outdoor Unit PCB LED Indicator Guide
2AMX, 3AMX Series LED Diagnostics
Understanding the LED indicators on the outdoor unit PCB for malfunction detection in 2AMX/3AMX series.
2AMX, 2AMXS Series LED Diagnostics
Understanding the LED indicators on the outdoor unit PCB for malfunction detection in 2AMX/2AMXS series.

Table of Contents