Summarization of Contents

What to Do Before Operation
Precautions for Group Control System or Two Remote Controllers
Details precautions for systems with group control or two remote controllers.
Safety Considerations
Warning Precautions
Important safety precautions indicating risks of death or serious injury.
Caution Precautions
Safety precautions indicating risks of injury or material damage.
Operation Range
Cooling Only Type Operation Range
Specifies temperature range for cooling only operation of the air conditioner.
Heat Pump Type Operation Range
Specifies temperature range for heat pump cooling and heating operations.
Installation Site
Recommended Installation Sites
Guidelines for selecting a suitable installation location for the air conditioner.
Prohibited Installation Sites
Lists locations where the air conditioner should not be installed due to specific conditions.
Wiring Requirements
Instructions for electrical wiring, emphasizing authorized electricians and separate circuits.
Noise and Obstruction Considerations
Advice on selecting a location to minimize noise and avoid air outlet obstructions.
Drain Piping Requirements
Ensuring proper drain piping for complete drainage to prevent water leakage.
Remote Controller Switches and Displays
ON/OFF Button Function
Describes the operation of the ON/OFF button to start and stop the system.
Operation Lamp Indicator
Explains the meaning of the red operation lamp lighting during system operation.
Display Icons and Meanings
Details the various display icons and their meanings on the remote controller.
Remote Controller Buttons
Explains the functions of specific buttons like TIMER, INSPECTION/TEST, PROGRAMMING TIME.
Operation Procedure
System Operation Modes
Details on operating modes like Cooling, Heating, Automatic, Fan, and Program Dry.
Temperature Setting
Instructions on how to set the desired temperature using the remote control buttons.
Fan Speed Control
How to select fan speed (High/Low) using the remote control button.
Program Timer Operation
Steps for programming start and stop times for automated operation.
Timer Mode Start/Stop
Procedure to select and activate timer modes for starting or stopping the system.
Program Timer Operation
Programming Time
Setting the time for stopping or starting the system using the programming time button.
Timer ON/OFF Activation
Activating or deactivating the timer function, indicated by display changes.
Optimum Operation
Operation Precautions
Guidelines for adjusting room temperature, ventilation, and closing windows for efficiency.
Maintenance (For Service Personnel)
Important Safety for Maintenance
Critical safety warnings for service personnel before accessing terminal devices.
Cleaning Air Filters
Procedure for cleaning air filters when the 'TIME TO CLEAN AIR FILTER' display appears.
Cleaning Air Outlet and Panels
Instructions for cleaning air outlets and exterior panels using a soft cloth or mild detergent.
Startup After Long Stop
Checks to perform before starting the unit after a prolonged period of non-operation.
Long Period System Stop
Procedure for stopping the system for extended periods, including drying and power cutoff.
Not Malfunction of the Air Conditioner
System Does Not Operate Immediately
Explains why the system may not restart instantly after button presses due to safety devices.
Centralized Control Display
Describes the display indicating centralized control, where the remote cannot manage the system.
Delayed Startup After Power On
Explains the delay before operation starts after the main power supply is turned on.
Trouble Shooting
White Mist from Unit
Reasons for white mist, including high humidity and internal unit contamination.
Normal Operational Noises
Describes sounds like ringing, 'Shuh', 'Shah', and 'Pishi-pishi' as normal operations.
Dust Emission After Long Rest
Explains dust blowing out after the unit has been idle for a long time.
Unit Odors
The unit may emit absorbed room odors like furniture, cigarettes, etc.
Remote Controller '88' Display
Indicates the remote controller is in normal condition after the main power is turned on.
Abnormal Conditions Warning
Immediate actions for abnormal conditions like burning smell, fuse actuation, or water leaks.
Malfunction Code Display
Procedure when a malfunction code appears on the display, requiring dealer notification.
System Does Not Operate
Checks for power failure, blown fuses, or tripped breakers when the system is completely off.
System Stops Operating
Troubleshooting steps if the system stops after running, checking for blockages or clogged filters.
Insufficient Cooling or Heating
Diagnosing issues with insufficient cooling/heating due to blockages, filters, settings, or room conditions.