MODE-DATA G

050 DATA DT GAIN

Function: Sets the data input level from the TNC to the
AFSK modulator.
Available Values: 0 ~ 100
Default Setting: 50

051 DATA OUT LVL

Function: Sets the AFSK data output level at the output
port (pin 5) of the RTTY/PKT jack.
Available Values: 0 ~ 100
Default Setting: 50

052 DATA VOX DLY

Function: Adjusts the "VOX" Delay (receiver recovery)
time in the PACKET mode.
Available Values: 30 ~ 3000 msec (10 msec/step)
Default Setting: 300 msec
053 DATA V GAIN
Function: Adjusts the "VOX" Gain in the PACKET mode.
Available Values: 0 ~ 100
Default Setting: 50

054 DATA PKTDISP

Function: Sets the packet frequency display offset.
Available Values: –3000 ~ +3000 Hz (10 Hz/step)
Default: 0 Hz

055 DATA PKT SFT

Function: Sets the carrier point during the SSB packet
operation.
Available Values: –3000 ~ +3000 Hz (10 Hz/step)
Default: 1000 Hz (typical center frequency for PSK31,
etc.)
FT-950 O
PERATING
ROUP
M
ANUAL
M
MODE-FM G

056 F3E MIC

Function: Sets the microphone gain for the FM mode.
Available Values: Ur/0 ~ 100
Default Setting: 50
When this menu is set to "Ur", you may adjust the micro-
phone gain using the front panel's [ MIC GAIN ] knob.

057 F3E 28 RPT

Function: Sets the magnitude of the repeater shift on the
28 MHz band.
Available Values: 0 ~ 1000 kHz (10 kHz/step)
Default Setting: 100 kHz

058 F3E 50 RPT

Function: Sets the magnitude of the repeater shift on the
50 MHz band.
Available Values: 0 ~ 4000 kHz (10 kHz/step)
Default Setting: 1000 kHz
MODE-RTTY G

059 RTTY R PLRTY

Function: Selects normal or reverse Mark/Space polarity
for RTTY receive operation.
Available Values: nor/rEV
Default Setting: nor
060 RTTY T PLRTY
Function: Selects normal or reverse Mark/Space polarity
for RTTY transmit operation.
Available Values: nor/rEV
Default Setting: nor

061 RTTY OUT LVL

Function: Sets the RTTY (AFSK) data output level at the
output port (pin 5) of the RTTY/PKT jack.
Available Values: 0 ~ 100
Default Setting: 50

062 RTTY SHIFT

Function: Selects the frequency shift for RTTY (AFSK)
operation.
Available Values:170/200/425/850 Hz
Default Setting: 170 Hz

063 RTTY TONE

Function: Selects the Mark tone for RTTY operation.
Available Values: 1275/2125 Hz
Default Setting: 2125 Hz