Numerical presentation
On the PI display, you must use two
channels to receive the information
from the SeineSounder. The depth
and height values are then shown in
the numeric display. If the height or
depth is increasing or decreasing, this
is shown with two arrows and the
variation in meters per minute.
You can also see the depth and
height changes as a function of time in
a graphical presentation.
When the readings are stable, the
digits are shown in black colour. If the
contact is lost, the characters *** are
shown in grey. If the height is out of
range, the displays shows ???.
Mounting
Location: Place the sensor where
you wish to monitor the height. This
is normally aft of the headrope at the
center of the net.
A
B
(CD012207C)
D
Simrad
Kongsberg Maritime AS
Strandpromenaden 50
P.O.Box 111
N-3191 Horten, Norway
(A) Sensor identification
(B) Unit of measurement
(C) Depth
(D) Depth change/
minute
(E) Arrow indicates that
the depth is increasing
(F) Visual alarm
(G) Sensor transmission
indicator
(H) Interference
warning
(I) Height
(J) Height change/minute
(K) Arrows pointing "out" means
that the depth is increasing, arrows
pointing "in" means that height is
decreasing
Ensure that you mount the sensor
with the reverse side (D) and the
echo sounder transducer (E) pointing
towards the bottom! The SIMRAD
print on the sensor (C) must point up
A
30
cm
C
B
E
Telephone: +47 33 03 40 00
Telefax: +47 33 04 29 87
www.simrad.com
simrad.sales@simrad.com
A
B
D1
[m]
F
H
H1
[m]
G
(CD012205D)
towards the water surface!
fastening lugs (A) using two snap
hooks and rope. Then, secure the
two aft fastening lugs (B) using snap
hooks and strong rubber bands. This
(A) Rope and snap
mounting places the sensor in a cradle
hooks
supported on all four sides.
(B) Rubber bands
and snap hooks
we recommend that you assemble a
(C) SIMRAD
bag of finemeshed net, and ties this
imprint on the
to the trawl close to the middle of the
sensor must point
headrope. Then, mount the sensor
up!
inside this bag. The sensor must be
(D) Reverse side of
properly secured to prevent it from
sensor
moving sideways or rotate during use.
(E) Echo sounder
Make sure that you have best possible
transducer must
free view between the sensor and the
point towards the
bottom, and between the sensor and
bottom!
the vessel.
C
43.5
21.8
I
Mounting: Secure the two forward
In order to secure the sensor in place,
NOTE!
For bottom and
pelagic trawl
applications, use
the SHORT key
bolt!
313699 / Rev.B / October 2007
D
E
6
1
J
K
Need help?
Do you have a question about the PI SEINESOUNDER TRAWLERS - QUICK REFERENCE GUIDE REV B and is the answer not in the manual?