CONTINUOUS DUTY
4" BLOWER
FEATURES
•
•
Extended Life 5,000 Hour Motor
•
Tough Reinforced Thermoset Plastic Housing
•
Mounts To Any Flat Surface
•
Slip-On Inlet Ducting Connection
•
Efficient High Volume Air Flow
•
Low-Current Draw
•
Corrosion-Resistant Materials Throughout
•
N.M.M.A. Type Accepted
Meets USCG Regulation 183.410 and
•
ISO 8846 MARINE for Ignition Protection
•
Complies with ISO 9097 MARINE
Conforms with BSEN 50081-2 for Supression
of Electro-magnetic interference
SPECIFICATIONS - Flangemount
Air
Model
Flow
35760-0092
250 CFM
(7,0 m
/min)
3
35760-0094
250 CFM
(7,0 m
/min)
3
SPECIFICATIONS - Flexmount
Air
Model
Flow
35770-0092
250 CFM
(7,0 m
/min)
3
35770-0094
250 CFM
(7,0 m
/min)
3
INSTALLATION
INSTALLATIONS MUST MEET APPLICABLE SECTIONS
OF TITLE 33, PART 183; SUBPART K, USCG VENTILATION
REGULATIONS.
FLANGEMOUNT MOUNTING
Mount blower on flat bulkhead surface in highest part of com-
partment free from spray or deck wash. Cut a 3-5/8"
hole in bulkhead and secure blower with washers and
No. 10 screws ( NOTICE: Tighten screws evenly to avoid
flange damage). Use a suitable discharge fitting so that
static pressure of blower will not be affected by change in
wind direction. Route inlet ducting with as few bends as pos-
sible to lower 1/3 of the bilge compartment where vapors are
likely to accumulate. Be sure ducting is positioned below top
of engine stringers but not so low as to become
submerged in bilge water. Locate pickup to take advantage of
natural air flow direction.
Models 35760-Series-Flangemount
Fuse
Weight
Voltage Amps
Size
12 Vdc
11
15
24 Vdc
6
10
Fuse
Weight
Voltage
Amps
Size
12 Vdc
11
15
24 Vdc
6
10
35770-Series-Flexmount
FLEXMOUNT
FLEXMOUNT MOUNTING
Mount blower on flat bulkhead surface in highest part of com-
lb (kg)
partment free from spray or deck wash. Blower may be rotated
in mounting bracket to facilitate the shortest route of ducting.
6 (2.72)
Use a suitable discharge fitting so that static pressure of blower
will not be affected by change in wind direction. Route inlet
ducting with as few bends as possible to lower 1/3 of the bilge
compartment where vapors are likely to accumulate. Be sure
ducting is positioned below top of engine stringers but not so
low as to become submerged in bilge water.
lb (kg)
Locate pickup to take advantage of natural air flow direction.
7 (3.18)
NOTICE: Blowers should be mounted away from extreme
heat (more than 130°F) to prevent distortion of blower wheel
or housing.
OPERATION: See following warning placard statement:
THE "WARNING" PLACARD SUPPLIED WITH BLOWER MUST
BE MOUNTED ADJACENT TO ENGINE IGNITION SWITCHES
(ALL LOCATIONS) TO COMPLY WITH TITLE
33, PART 183; SUBPART K, USCG VENTILATION
REGULATIONS. *
*Additional warning placards are available from factory by re-
questing form 43003-0418.
FLANGEMOUNT