Pillar tap faucet

Advertisement

Quick Links

METERING
PILLAR TAP FAUCET
Thank you for selecting American-Standard...the
benchmark of fine quality for over 140 years.
To ensure that your installation proceeds smoothly--please
read these instructions carefully before you begin.
Recommended Tools
Tubing Cutter
Channel Locks
1
FAUCET INSTALLATION (With optional 4" Deck Plate)
Turn off hot and cold water
CAUTION
supplies before beginning.
Install SEAL (1) into base of FAUCET (2). Assemble Optional DECK PLATE (3), and PUTTY PLATE (4) to FAUCET BODY (2) with
SCREW (5). Apply a bead of putty to underside of PUTTY PLATE (4). Fig. 1a.
Insert FLEX HOSE (6) and SPOUT SHANK (7) through center hole of mounting surface. Fig. 1a.
Assemble "C" WASHER (8) and LOCKNUT (9) onto threads of SPOUT SHANK (7) from underside of mounting surface. Fig. 1b.
Align FAUCET (2) and tighten LOCKNUT (9). If installing DECK PLATE (3) hand tighten DECK PLATE SPIN NUTS (10) to secure
FAUCET (2) to mounting surface. Fig. 1b.
Fig. 1a
SPOUT
RECESS
5
2
CONNECT WATER SUPPLY
Connect 3/8" compression
coupling nut on fitting supply
hose to cold water
supply or tempered
water supply.
Adjustable Wrench
2
1
3
4
APPLY PUTTY
MOUNTING
SURFACE
3/8"
COMPRESSION
COLD WATER
OR TEMPERED
WATER SUPPLY
Installation
Instructions
1340.105
1340M.105
1340.109
1340M.109
1340.107
1340M.107
1340.119
1340M.119
Plumbers' Putty or Caulking
Note: Faucet can be installed as single hole installation or
with (OPTIONAL) 4" or 8" DECK PLATES. 4" No. 605P400
& 8" No. 605P800 Deck Plates must be ordered separately.
Fig. 1b
3
10
3
TEST INSTALLED FITTING
Turn on water supplies
and check connections
for leaks.
Remove AERATOR (1) with
KEY (2) supplied.
Operate FAUCET by pressing
down on HANDLE (3). Handle
is set for approximately
8 second operating cycle.
Replace AERATOR (1).
Certified to comply with ANSI A112.18.1M
M968497 REV.1.7 (8/19)
2.5mm Hex Wrench
Hook
7
8
9
6
PRESS HANDLE
DOWN TO OPERATE
1
2
3

Advertisement

loading
Need help?

Need help?

Do you have a question about the METERING 1340.105 and is the answer not in the manual?

Questions and answers

Summary of Contents for American Standard METERING 1340.105

  • Page 1 Installation Instructions 1340.105 METERING 1340M.105 PILLAR TAP FAUCET 1340.109 1340M.109 Thank you for selecting American-Standard...the 1340.107 benchmark of fine quality for over 140 years. 1340M.107 1340.119 To ensure that your installation proceeds smoothly--please Certified to comply with ANSI A112.18.1M 1340M.119 read these instructions carefully before you begin.
  • Page 2 TO ADJUST CYCLE TIME Remove HANDLE (1) by removing INDEX BUTTON (2) and SET SCREW (3) with a 2.5mm hex wrench. Pull off HANDLE (1). 2.5mm HEX WRENCH To increase cycle time, turn the gray PLASTIC ADJUSTING NUT (4) clockwise. TO DECREASE TO INCREASE CYCLE TIME...
  • Page 3 METERING Pillar Tap Faucets PRODUCT NUMBER 1340.105 1340.107 1340M.105 1340M.107 M962390-002OA 1340.109 1340.119 HANDEL KIT 1340M.109 1340M.119 M962391-0070A INDEX KIT M952212-0020A M964476-002OA ACTUATOR UNIT VALVE KIT M952230-0070A METERING VALVE M922996-0020A VR AERATOR, 1.0 GPM 066508-0020A VR SPRAY, 0.5 GPM A911748-0070A SEAL *605P400.002 4"...

This manual is also suitable for:

Metering 1340m.105Metering 1340.109Metering 1340m.109Metering 1340.107Metering 1340m.107Metering 1340.119 ... Show all