INSTALLATION INSTRUCTIONS
Model: TGDDS
Double LED Dimmer
* Two Single-Pole Only
* Neutral NOT REQUIRED
SPECIFICATIONS
Operating Control , Wall Mounted Switch Control
Construction of control.................. Independently Mounted for Flush Mounting
Voltage.......................................................................................120VAC, 60Hz
Load 1.......................................................................................300 W INC/HAL
.......................................................................................200 W LED/CFL
Load 2.......................................................................................300 W INC/HAL
.......................................................................................200 W LED/CFL
Type of Action.....................Type 1.B Action
(Micro-Disconnection for Air Gap)
Pollution Degree...............................................................................................2
Rated Impulse Voltage.............................................................................2500V
Operating Temperature............................................32° F - 104° F (0° - 40° C)
Wire Gauge...............................................................................#14 ~ #12 AWG
WARRANTY
This device is warranted to be free of material and workmanship defects for 1 year from the date of purchase. Original receipt or proof of purchase from an authorized retailer must be presented upon warranty claim. ALL
claims must be verified and approved by Top Greener, Inc. Warranties from other TOPGREENER products may vary. This warranty is nontransferable and does not cover normal wear and tear or any malfunction, failure,
or defect resulting from misuse, abuse, neglect, alteration, modification, or improper installation. To the fullest extent permitted by the applicable state law, Top Greener, Inc. shall not be liable to the purchaser or end user
customer of TOPGREENER products for direct, indirect, incidental, or consequential damages even if Top Greener, Inc. has been advised of the possibility of such damages. Top Greener, Inc's total liability under this or
any other warranty, express or implied, is limited to repair, replacement or refund. Repair, replacement or refund are the sole and exclusive remedies for breach of warranty or any other legal theory.
WIRING DIRECTIONS
1. Remove the wall plate.
2. Remove existing switch from wall box and prior to disconnecting
wires, identify the wires and label as needed.
3. Remove wires from existing switch.
4. Follow the diagram below to connect the TGDDS
TGDDS dimmer
replaces standard
on/off switches and does
not require other
control modules.
Power
HOT
Ground
LOAD 1
OPERATING INSTRUCTIONS
The dimming slider has an off position
Dimmer for
Load 1
when you move the slider all the way
down. There will be a noticeable click
when you slide to turn on or off.
Be sure to use dimmable light bulbs!
Dimmer for
Load 2
IMPORTANT NOTICE
This device is designed for two light loads
You must have two load wires in the switch box and a HOT wire
in order to use this dimmer. One load wire goes to
the LOAD 1 and the other load wire goes to the LOAD 2
2. Tighten
screw
WARNING
Turn the power off at the circuit breaker before installing this device.
1. Insert
wire
Read and understand these instructions before installing. This device is intended for
installation in accordance with the National Electric Code and local regulations. It is
recommended that a qualified electrician performs this installation. Make sure to turn
off the circuit breaker or fuse(s) and make sure power is off before wiring the device.
Use copper wire only. No Aluminum.
INPUT: Use wires with minimum rating of 167° F (75° C)
CAUTION
other equipment, Do Not Install to control a receptacle, motor-operated appliance,
fluorescent lighting fixture or a transformer supplied appliance.
-
Risk of Electric Shock - More than one disconnect switch may be required to
de-energize the device before servicing
ATTENTION
à d'autres équipements, ne pas installer pour contrôler un réceptacle, un appareil à
moteur ou un luminaire fluorescent ou un appareil fourni par transformateur.
-
Risque de choc électrique - plus d'un interrupteur de déconnexion peut être
nécessaire pour débrancher l'appareil avant l'entretien
Power
HOT
Ground
LOAD 1
- To reduce the risk of overheating and possible damage to
- Pour réduire le risque de surchauffe et les possibles dommages
© 2021 Top Greener, Inc. CA, U.S.A. WWW.TOPGREENER.COM 0212210165-02