Calibrating The Expression Pedal - DigiTech BRIAN MAY RED SPECIAL PEDAL Owner's Manual

Table of Contents

Advertisement

Connections Diagram -
Flexible Output Mode
3 (Stereo Amp)
TM
AMPLIFIER
AMPLIFIER
PS0913B
FS3X FOOTSWITCH
(OPTIONAL)

Calibrating the Expression Pedal

If the Expression Pedal's range becomes diminished over time, it may be
necessary to re-calibrate the pedal. Here is the procedure for calibration:
1. Begin with the power disconnected from the Red Special Pedal.
2. Select Model 1 using the MODEL knob.
3. Insert a standard mono (TS) guitar cable into the FOOTSWITCH
jack.
4. Connect the power supply to the Red Special Pedal. The INDICA-
TOR LED begins flashing yellow.
5. Rock the EXPRESSION PEDAL forward (toe down).
6. Select Model 2 using the MODEL knob. Wait for the INDICATOR
LED to begin flashing green.
7. Rock the EXPRESSION PEDAL back (toe up).
8. Select Model 3 using the MODEL knob. The INDICATOR LED
should flash green three times if calibration was successful.
If the calibration procedure fails, the INDICATOR LED will flash red
instead of green during step 8 and the unit will not return to normal
operation until the Expression Pedal has been properly calibrated. Select
Model 1 using the MODEL knob at this time and repeat steps 5-8 until
Expression Pedal calibration is successful.