Download Print this page
schmersal AZM 161ST-11/12RKA-024 Operation And Assembly Instructions
schmersal AZM 161ST-11/12RKA-024 Operation And Assembly Instructions

schmersal AZM 161ST-11/12RKA-024 Operation And Assembly Instructions

Solenoid interlock

Advertisement

Quick Links

INSTRUKCJE UŻYTKOWANIA I MONTAŻU
Solenoid interlock AZM 161ST-11/12RKA-024
Table of Contents
1 About this document
1.1 Function
1.2 Target group of the operating instructions: authorised qualified personnel
1.3 Explanation of the symbols used
1.4 Appropriate use
1.5 General safety instructions
2 Product description
2.1 Ordering code
2.2 Special versions
2.3 Purpose
2.4 Warning about misuse
2.5 Exclusion of liability
2.6 Technical Data
3 Mounting
3.1 General mounting instructions
3.2 Dimensions
3.3 Manual release
3.4 Emergency release (ordering suffix -N)
3.5 Emergency Exit
4 Electrical connection
4.1 General information for electrical connection
4.2 Contact Options
5 Set-up and maintenance
6 Disassembly and disposal
6.1 Disassembly
6.2 Disposal
1 About this document
1.1 Function
This document provides all the information you need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the switchgear. The operating instructions enclosed with the device must always be
kept in a legible condition and accessible.
1.2 Target group of the operating instructions: authorised qualified
personnel
1-19

Advertisement

loading
Need help?

Need help?

Do you have a question about the AZM 161ST-11/12RKA-024 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmersal AZM 161ST-11/12RKA-024

  • Page 1 INSTRUKCJE UŻYTKOWANIA I MONTAŻU Solenoid interlock AZM 161ST-11/12RKA-024 Table of Contents 1 About this document 1.1 Function 1.2 Target group of the operating instructions: authorised qualified personnel 1.3 Explanation of the symbols used 1.4 Appropriate use 1.5 General safety instructions 2 Product description 2.1 Ordering code...
  • Page 2 The user must observe the safety instructions in this operating instructions manual, the country specific installation standards as well as all prevailing safety regulations and accident prevention rules. Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet: products.schmersal.com.
  • Page 3 Product type description: AZM161 (1)-(2)(3)K(4)-(5)/(6)-(7)(8) Screw connection Cage clamps Connector plug M12 11/03 Magnet: 1 NO contact, 1 NC contact / Actuator: 3 NC contacts with connector plug 12/03 Magnet: 1 NO contact, 2 NC contact / Actuator: 3 NC contacts 12/11 Magnet: 1 NO contact, 2 NC contacts / Actuator: 1 NO contact, 1 NC contact with connector plug...
  • Page 4 Us: 24 VAC/DC 110/230 Us: 110/230 VAC without without LED with LED (only for Us: 24 VAC/DC) 2.2 Special versions For special versions, which are not listed in the ordering code, these specifications apply accordingly, provided that they correspond to the standard version. 2.3 Purpose The solenoid interlock has been designed to prevent in conjunction with the control part of a machine, movable safety guards from being opened before hazardous conditions have been eliminated.
  • Page 5 2.6 Technical Data Approvals - Standards Certificates cULus General data Standards EN ISO 13849-1 EN ISO 14119 EN IEC 60947-5-1 Coding level according to EN ISO 14119 niskie Working principle elektromechaniczne Housing material Tworzywo sztuczne, tworzywo​ ​ termoplastyczne​ ​ wzmocnione​ ​ włóknem​...
  • Page 6 Please note: Możliwość zastosowania po dokonaniu wykluczenia błędów w postaci niebezpiecznego uszkodzenia 1-kanałowej mechaniki i odpowiednim zabezpieczeniu przed manipulacją. Performance Level, up to Category Note for 2-channel use and with suitable logic unit. Mission time 20 Year(s) Mechanical data Mechanical life, minimum 1 000 000 Operations Actuating play in direction of actuation 5,5 mm...
  • Page 7 Permissible installation altitude above sea level, maximum 2 000 m Ambient conditions - Insulation values Rated insulation voltage U 250 VAC Konektor 4-polowy - 250 V Konektor 8-polowy - 60 V Rated impulse withstand voltage U 0,8 kV Rated impulse withstand voltage, connector 4-pole 2.5 kV Rated impulse withstand voltage, connector 8-pole 0.8 kV...
  • Page 8 Other data Note (applications) przesuwna osłona bezpieczeństwa osłona zdejmowana uchylna osłona bezpieczeństwa Note about the safety classification - Safety classification of the interlocking function Basically suitable up to Cat. 1 / PL c. With 2-channel usage with fault exclusion mechanism (if a fault exclusion to the 1-channel mechanics is authorised) and suitable logic applicable up to Cat.
  • Page 9 Legend Safety power shutdown ¢ Solenoid interlock ƒ Guard locking function ¥ Fault exclusion with regard to wiring routing must be observed. If for a certain application the power to unlock version of a solenoid interlock cannot be used, for this exception an interlock with power to lock can be used if additional safety measure need to be realised that have an equivalent safety level.
  • Page 10 3 Mounting 3.1 General mounting instructions Please observe the remarks of the standards EN ISO 12100, EN ISO 14119 and EN ISO 14120. Three mounting holes are provided for fixing the enclosure. The solenoid interlock is double insulated. The use of an earth wire is not authorised.
  • Page 11 3.3 Manual release (for set-up, maintenance, etc.) Manual release is realised by turning the triangular key by 180° (M5 triangular key available as accessory), so that the locking bolt is pulled into the unlocking position. Please ensure that jamming by external influence on the actuator is avoided.
  • Page 12     Triangular key TK-M5 (101100887) available as accessory. 3.4 Emergency release (ordering suffix -N) (Fitting and actuation only from outside the hazardous area) The emergency release should only be used in an emergency. The solenoid interlock should be installed and/or protected so that an inadvertent opening of the interlock by an emergency release can be prevented.
  • Page 13     4 Electrical connection 4.1 General information for electrical connection The electrical connection may only be carried out by authorised personnel in a de-energised condition. If the risk analysis indicates the use of a monitored interlock they are to be connected in the safety circuit with the contacts >...
  • Page 14 Once the connection has been made, clean any dirt from the inside of the switch and refit the housing cover. The tightening torque of the cover screws is 0.6 Nm. The tightening sequence of the screws is shown in the following illustration.
  • Page 15 Power to unlock Power to lock AZM 161SK-12/12... und AZM 161CC-12/12...     AZM 161SK-12/03... und AZM 161CC-12/03...     Positive break NC contact Monitoring the interlock according to EN ISO 14119 > Actuated Not actuated AZM 161ST-../.. with connector AZM 161ST-12/11...
  • Page 16     AZM 161ST-11/03...       AZM 161...-G with LED Integrated contact kit 12/12 G (with LED) 16-19...
  • Page 17 The 24 V are led internally to contacts 13 and 63. The corresponding signals of the LED display can also be tapped at terminals 14 or 64.   Integrated contact kit 12/03 G (with LED) The 24 V are led internally to contacts 11 and 63. The corresponding signals of the LED display can also be tapped at terminals 12 or 64.
  • Page 18 Power to unlock System condition Magnet control ¢ ƒ ¥ Power to unlock yellow green yellow Door open 24 V (0 V) Door closed, actuator 24 V inserted, not locked Door closed, actuator inserted and locked Power to lock System condition Magnet control ¢...
  • Page 19 19-19 Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220 Dane zostały starannie sprawdzone. Zdjęcia mogą odbiegać od rzeczywistości. Dalsze dane techniczne znajdują się w instrukcji obsługi. Możliwe są zmiany i błędy techniczne.