Kinghome KM09XK1DI Owner's Manual

Advertisement

Quick Links

Owner's Manual
Original Instructions
Cassette Type Air Conditioner
Thank you for choosing our product.
Please read this Owner's Manual carefully before operation and
retain it for future reference.
NOTE:
Actual product may be different from graphics,
please refer to actual products.
Model
KM09XK1DI
KM12XK1DI
KM18XK1DI
KM20XK1DI

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KM09XK1DI and is the answer not in the manual?

Questions and answers

Summary of Contents for Kinghome KM09XK1DI

  • Page 1 Model KM09XK1DI KM12XK1DI KM18XK1DI KM20XK1DI Owner's Manual Original Instructions Cassette Type Air Conditioner Thank you for choosing our product. Please read this Owner’s Manual carefully before operation and retain it for future reference. NOTE: Actual product may be different from graphics,...
  • Page 3: Table Of Contents

    Contents 1 Safety Notices (Please be sure to abide)················································· 1 2 Product Introduction ············································································· 3 2.1 Names of Key Components ································································· 3 2.2 Rat ed Working Condition ···································································· 4 2.3 Operation and Introduction of Remote Controller ······································· 4 3 Preparations for Installation ································································· 11 3.1 Installation Position Selection·····························································...
  • Page 4: Explanation Of Symbols

    Explanation of Symbols WARNING This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to CAUTION property. Indicates important but not hazard-related information, used NOTICE to indicate risk of property damage. Exception Clauses Manufacturer will bear no responsibilities when personal injury or property loss is caused by the following reasons.
  • Page 5: Safety Operation Of Flammable Refrigerant

    The refrigerant process or to clean,other than those recomm- Refrigerant Before install the ended by the manufacturer. Safety Group appliance, read Servicing shall be performed only as recomm- the installation ended by the manufacturer. Appliance filled with manual first. Should repair be necessary,contact your nearest flammable magas R32.
  • Page 6: Maintenance Notes

    Safety operation of flammable refrigerant Filling the refrigerant table a - Minimum room area ( m Based on UL 60335-2-40 requirements Use the refrigerant filling appliances specia- The following installation height and area for lized for R32. Make sure that different kinds of refrigerant won’t contaminate with each other.
  • Page 7 Safety operation of flammable refrigerant Pressure test and leak detect magnetic interference, chemical substances (such as chemical plants, etc.), flammable After completion of field piping for split gas, combustible and explosive gas and systems, the field pipework shall be pressure smog, etc.
  • Page 8: Operation And Maintenance

    GENERAL INFORMATION WARNING Operation and Maintenance This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 9 GENERAL INFORMATION WARNING If the air conditioner operates under abnormal conditions, it may cause malfunction,electric shock or fire hazard. When turning on or turning off the unit by emergency operation switch, please press this switch with an insulating object other than metal. Do not step on top panel of outdoor unit, or put heavy objects.
  • Page 10 GENERAL INFORMATION WARNING The appliance shall be installed h t i i t a i r i i t a a l l o i t h t i CEC by authorized personnel only. The air conditioner is the first class electric appliance. It must be properly grounding with specialized grounding device by a professional.
  • Page 11 GENERAL INFORMATION WARNING Do not splash or pour water on a ir conditioner. Otherwise, it may cause short circuit or damage to air conditioner. Prohibit operating heating equipment around the air conditioner. Prohibit operating the unit in the bathroom or laundry room. Far away from fire source, inflammable and explosive objects.
  • Page 12: Safety Notices (Please Be Sure To Abide)

    Multi Variable Air Conditioners One-way Cassette Type Indoor Unit 1 Safety Notices (Please be sure to abide) WARNING! If not abide strictly, it may cause severe damage to the unit or the people. NOTE! If not abide strictly, it may cause slight or medium damage to the unit or the people.
  • Page 13 Multi Variable Air Conditioners One-way Cassette Type Indoor Unit Diameter of power cord must After the power cord is be large enough. Damaged Connected, please install the power cord and connecting wire cover of electric box to avoid must be replaced by danger.
  • Page 14: Product Introduction

    Multi Variable Air Conditioners One-way Cassette Type Indoor Unit If abnormal condition occurs (e.g. unpleasant smell), please Do not repair the air turn off the unit at once and conditioner by yourself. disconnect power supply. Then Improper repair will cause contact service center.
  • Page 15: Rated Working Condition

    Multi Variable Air Conditioners One-way Cassette Type Indoor Unit 2.2 Rated Working Condition Indoor Side Condition Outdoor Side Condition Test condition Dry Bulb Temp℃(℉) Wet Bulb Temp℃(℉) Dry Bulb Temp℃(℉) Wet Bulb Temp℃(℉) Rated Cooling 26.7(80) 19.4(67) 35.0(95) 23.9(75) Rated Heating 21.1(70) 15.6(60) 8.33(47)
  • Page 16 Multi Variable Air Conditioners One-way Cassette Type Indoor Unit Introduction for buttons on ● When selecting heat mode, the air conditioner remote controller operates under heat mode. Press " + " or " - " button to adjust set temperature. Press "Fan" NOTE button to adjust fan speed.
  • Page 17 Multi Variable Air Conditioners One-way Cassette Type Indoor Unit swing angle . When reaching your required + / - button angle, release the button. Press " + " or " - " button once increase or decrease NOTE set temperature 1℃(℉). Holding " + " or " - " button, ●...
  • Page 18: Function Introduction For Combination Buttons

    Multi Variable Air Conditioners One-way Cassette Type Indoor Unit Function introduction for Timer on / Timer off button combination buttons TIMER ON button ● "TIMER ON" button can set the time for timer Energy-saving function on. After pressing this button, " "...
  • Page 19 Multi Variable Air Conditioners One-way Cassette Type Indoor Unit following: NOTE blank ● No Setting Once the reminder function is turned on, only this cycle reminder can be cleared. ● This function is only available for some models. ● Maximum power limited under the mode is lower than that of mode.
  • Page 20 Multi Variable Air Conditioners One-way Cassette Type Indoor Unit ● Sleep 3 the sleep curve setting under Sleep mode according to the detected temperature. Press by DIY could be inquired: "Health" and " + " buttons simultaneously again to The user could accord to sleep curve setting method turn off I FEEL function and "...
  • Page 21: Replacement Of Batteries In Remote Controller

    Multi Variable Air Conditioners One-way Cassette Type Indoor Unit Replacement of batteries in remote controller reinstall battery remove Cover of battery box Press the back side of remote c ontroller marked with " ", as shown in the fig, and then push out the cover of battery box along the arrow direction.
  • Page 22: Preparations For Installation

    Multi Variable Air Conditioners One-way Cassette Type Indoor Unit 3 Preparations for Installation NOTE! This picture is for reference only, please refer to the actual product, the unit of dimension is mm. 3.1 Installation Position Selection (1) The appliance shall not be installed in the laundry. (2) The location should be able to withstand the weight of unit.
  • Page 23: Wiring Requirement

    Multi Variable Air Conditioners One-way Cassette Type Indoor Unit 3.2 Wiring Requirement Dimension of power cord. Power Supply Fuse Capacity Min. Power Supply Cord Indoor Units V/Ph/Hz 09K、12K 208/230V~ 60Hz 4xAWG18 18K、20K NOTES! An all-pole disconnection switch having a contact separation of at least 3mm in all ①...
  • Page 24 Multi Variable Air Conditioners One-way Cassette Type Indoor Unit Fig 4.1.2 Fig 4.1.3 Insert the M10 expansion bolt into the hole and then knock the nail into the bolt, as shown in fig 4.1.4. NOTE! The length of bolt depends on the installation height of the unit, bolts are field supplied.
  • Page 25: Refrigerant Pipe Connection

    Multi Variable Air Conditioners One-way Cassette Type Indoor Unit (6) Remove the washer locating plate and then tighten the nut on it. (7) Remove the paper pattern. Fig 4.1.5 NOTE! ① Drilling of ceiling opening and installation of air conditioner must be performed by professionals! ②...
  • Page 26 Multi Variable Air Conditioners One-way Cassette Type Indoor Unit (2) It is not allowed to connect the condensate drain pipe into rain pipe to prevent rain water from pouring in and cause property loss or personal injury. (3) Condensate drain pipe should be connected into special drain system for air conditioner.
  • Page 27 Multi Variable Air Conditioners One-way Cassette Type Indoor Unit (8) The installation height of raising pipe for drainage should be lower than B. The gradient from raising pipe towards drainage direction should be at least 1%~2%. If the raising pipe is vertical with the unit, the raising height should be less than C. Fig 4.3.3 model A(mm)
  • Page 28: Panel Installation

    Multi Variable Air Conditioners One-way Cassette Type Indoor Unit Fig 4.3.5 4.4 Panel Installation 4.4.1 Notices for Installation (1) Improper decorative panel installation could cause the following problems. Fig 4.4.1 (2) Ensure that it’s clearance-free between decoration panels and ceiling board after installation, if not, please adjust the body position.
  • Page 29 Multi Variable Air Conditioners One-way Cassette Type Indoor Unit Fig 4.4.3 4.4.2 Panel Installation (1) Remove the grille from the panel, and then open the horizontal louver. (2) Aim the screw hole on panel at the corresponding screw hole on main unit. (3) Screw up the screws on corresponding holes and then install the corresponding screw cover.
  • Page 30: Wired Controller Installation

    Multi Variable Air Conditioners One-way Cassette Type Indoor Unit 4.5 Wired Controller Installation Wired controller is optional accessory. If wired controller is needed, please contact your local dealer and install the wired controller according to the instruction manual. NOTE! Do perform the commissioning operation before first use, automatic addressing or other settings, please refer to the manual of ODU.
  • Page 31 Multi Variable Air Conditioners One-way Cassette Type Indoor Unit (2) The connection of stranded wire (as shown in fig 5.1.2) Strip about 10mm insulation of the end of stranded wire by stripping and cutting tool. Loosen the wiring screws on terminal board. Insert the wire into the ring tongue terminal and tighten by crimping tool.
  • Page 32: Installation Of Controllers

    Multi Variable Air Conditioners One-way Cassette Type Indoor Unit (4) Electric wiring between the indoor and outdoor units Si ngle-phase units(09~20K) N(1) green white black (yellow- (blue) (brown) green) Outdoor unit connection (5) Electric wiring of indoor unit side Re move the electric box cover from the electric box sub-assy and then connect the wire. CAUTION! Tighten the power cord respectively on the terminal boards with screws.
  • Page 33: Routine Maintenance

    Multi Variable Air Conditioners One-way Cassette Type Indoor Unit 6 Routine Maintenance 6.1 Maintenance before the Seasonal Use (1) Check if the air inlet and air outlet of indoor and outdoor unit are blocked. (2) Check if securely grounded. (3) Check if all power cords are securely connected. (4) Check if any error code displayed after energized.
  • Page 34: Trial Operation And Testing

    Multi Variable Air Conditioners One-way Cassette Type Indoor Unit Trial Operation and Testing (1) The meaning of error codes as shown below: Number Error code Error Compressor high pressure protection Indoor anti-freeze protection Compressor low pressure protection, refrigerant lack protection and refrigerant colleting mode Compressor high discharge temperature protection AC over-current protection Communication error...
  • Page 35: Troubleshooting

    Multi Variable Air Conditioners One-way Cassette Type Indoor Unit 8 Troubleshooting If your air-conditioning unit suffers from abnormal operation or failure, please first check the following points before repair: Failure Possible Reasons The power supply is not connected. ① Electrical leakage of air-conditioning unit causes tripping of the leakage ②...
  • Page 36: Specialist's Manual

    Multi Variable Air Conditioners One-way Cassette Type Indoor Unit 9 Specialist’s Manual Aptitude requirement for maintenance If any hot work is to be conducted on the refriger- man(repairs s hould be done only be ating equipment or any associated parts, appro- specialists).
  • Page 37 Multi Variable Air Conditioners One-way Cassette Type Indoor Unit resistant to being corroded or are suitably protect- most refrigerants but the use of detergents con- ed against being so corroded. taining chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the Checks to electrical devices ●...
  • Page 38 Multi Variable Air Conditioners One-way Cassette Type Indoor Unit Charging procedures ● Do not overfill cylinders. (No more than 80% volume liquid charge). In addition to conventional charging procedures, Do not exceed the maximum working pressure the following requirements shall be followed. of the cylinder, even temporarily.
  • Page 39: Disposal Of Equipment Using Flammable Refrigerants

    Multi Variable Air Conditioners One-way Cassette Type Indoor Unit to an acceptable level to make certain that flam- mable refrigerant does not remain within the lubricant. The compressor body shall not be heated by an open flame or other ignition sources to accelerate this process.
  • Page 40 GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI Add: West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070...

This manual is also suitable for:

Km12xk1diKm18xk1diKm20xk1di

Table of Contents