PVR EU 205 Operating And Maintenance Instructions Manual

Lubricated vane vacuum pump

Advertisement

Quick Links

EU 205 - EU 205/B
EU 300 - EU 300/B
Lubricated vane
vacuum pump
Operating and maintenance
instructions
Publication Number:
LI 1586.03 January 2020
EN
TRANSLATION

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EU 205 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PVR EU 205

  • Page 1 EU 205 - EU 205/B EU 300 - EU 300/B Lubricated vane vacuum pump Operating and maintenance instructions Publication Number: LI 1586.03 January 2020 TRANSLATION...
  • Page 2: Table Of Contents

    Operating and maintenance instructions Index 1. General information ....................page 3 2. Product specifications ..................page 4 2.1 Pump description ..................... page 4 2.2 Expected use .....................page 5 2.3 Forbidden use....................page 5 2.4 Protections ......................page 5 2.5 Accessories .......................page 5 3. Safety rules ......................page 6 4.
  • Page 3: General Information

    Operating and maintenance instructions 1. General information This manual contains information necessary for the proper operation of the pump in order to prevent unsuitable use and for the safety of the operators. Do not attempt any other type of operation without having first contacted our Service Department. The information provided herewith does not intend to replace, integrate or change any rules, regulations, law by decree, directive or law of specific character in force in the Country where the installation takes place.
  • Page 4: Product Specifications

    Operating and maintenance instructions 2. Product specifications 2.1 Pump description EU 205 - EU 300 pumps are single-stage, rotary vane lubricated vacuum pumps, with oil recirculation. The flanged electric motor is coupled by means of an elastic coupling. Cooling is achieved by means of an air/oil cooler and a centrifugal fan.
  • Page 5: Expected Use

    40°C. In case you get temperatures outside this range, please get in touch with us. Handling of other types of gas or vapours must be declared in advance to PVR that will give the conformity to the specific use.
  • Page 6: Safety Rules

    Operating and maintenance instructions 3. Safety rules WARNING: Despite of all the precautions adopted when designing the equipment, there are some risk elements that arise during operation and servicing. HOT SURFACES The temperature of the pump surfaces may exceed 80°C. Install the pump in a protected area accessible only by authorized personnel, to prevent possible personal injures due to contact with hot surfaces.
  • Page 7: Electric Safety

    Operating and maintenance instructions ELECTRIC SAFETY Some components of the electric equipment are electrically charged during operation. Any contact may cause serious injuries to persons or objects. Connection and control of the electric system must be carried out by skilled personnel only.
  • Page 8: Transport/Handling

    In case of damages are found, inform immediately PVR and the carrier. A representative will contact you or it may be dispatched to the site to inspect and file full damage report.
  • Page 9: Installation And Operation

    Operating and maintenance instructions 5. Installation and operation 5.1 Assembly If the pump is supplied without any electric motor, install a motor whose characteristics are the same as stated on the technical sheet, constructive form IM B 5. WARNING: - Use lifting equipment suitable for the motor weight (between 30 and 50 Kg depending on the versions) - To assure the continuity of the equipotential circuit of the pump, clean the contact surfaces very well, by removing any grease or protective painting.
  • Page 10: Operating Vacuum Range Changing

    Operating and maintenance instructions 5.2 Operating vacuum range changing Pumps of EU205 - EU300 series are fitted with a manual selector switch for the choi- ce of the suitable working vacuum range: · EU from 0.5 to 300 mbar · EU/B from 10 to 850 mbar In case the pump working range needs to be changed, please follow the instructions (fig.3).
  • Page 11: Location

    Operating and maintenance instructions 5.3 Location WARNING: The pump must be installed in a protected area (see safety rules). It must be fastened with support feet on horizontal surface. It must be accessible for correct and easy maintenance, by respecting the minimum distances from possible obstructions (see figure 6).
  • Page 12: Connection To The Machine

    Operating and maintenance instructions 5.4 Connection to the machine The connection to the chamber to be pumped down must be carried out by means of pipes of the same diameter as the inlet port. Pipe weights and expansions, if any, must not rest on the pump. It is advisable to make the final connection to the pump inlet port with flexible pipes or fittings.
  • Page 13: Electrical Connection

    Operating and maintenance instructions 5.6 Electrical connection The control panel and electrical connections must be carried out by skilled personnel and conform to the EN 60204-1 rules or to other local regulations in the Country of use. The electrical equipment must comply with EN 61000-6-4 and EN 61000-6-2 standards concerning electromagnetic compatibility, emission standard and immunity for industrial environment.
  • Page 14: Commissioning

    Operating and maintenance instructions 5.7 Commissioning The pump is supplied without lubricating oil. NOTE: the operation without oil causes big damages to the pump. Carry out the first filling up through the plug (E) up to the half of the sight glass (F) and close the plug (E) (Figure 8).
  • Page 15: Water Vapour Intake

    Operating and maintenance instructions 5.9 Water vapour intake In order to pump down any water vapour, the following operations are recommended: Let the pump run for thirty minutes at the maximum vacuum in order to bring the pump temperature to its operating value. At the end of the working cycle, in case of further presence of condensate in the oil, let the pump run for at least thirty minutes at the maximum vacuum.
  • Page 16: General Information

    Operating and maintenance instructions 6.1 General information In order to keep the pump operating at a high efficiency level, it is mandatory to follow all periodical service points listed in the table below.However, more frequent service operations may be necessary depending on what the pump is used for (suction of con- densable vapours, suction of powders or polluting substances).
  • Page 17: Coupling Elastic Element Replacement

    Operating and maintenance instructions 6.2 Oil change For a correct operation, oil change should be performed when the pump is still warm. WARNING: Use protective gloves to avoid injury caused by heat. Please refer to Figure 8, section 5.6.Unscrew the oil filling plug (E) and the discharge plug (G) only after having placed underneath the pump tank a suitable container (proper size and shape) for collecting the total quantity of oil.
  • Page 18: Exhaust Filters Replacement

    Operating and maintenance instructions 6.4 Exhaust filters replacement Very dirty exhaust filters may cause a considerable pump temperature increase and in extreme cases oil lubricant spontaneous ignition. Maximum allowed pressure in the tank is 0,6 bar measured at the maximum capacity (when the pump is working with the inlet open to atmospheric pressure).
  • Page 19: Lubricants

    9. Return for repair In case of pump return for repair to PVR, provide a list of substances which have come in contact with the pump and advise the risks involved in handling, if any. Drain the lubricant from the pump prior to shipping the pump back.
  • Page 20: Disposal

    Operating and maintenance instructions 10. Disposal Meaning of the “WEEE” logo found in labels The following symbol is applied in accordance with the EC WEEE (Waste Electrical and Electronic Equipment) Directive. This symbol (valid only in countries of the European Community) indicates that the product it applies to must NOT be disposed of together with ordinary domestic or industrial waste but must be sent to a differentiated waste collection system.
  • Page 21: Troubleshooting

    Operating and maintenance instructions 11. Troubleshooting TROUBLE CAUSE REMEDY Inlet pipes or machine are leaking Identify leaking point and seal it Check oil level and oil conditions. No lubrication Fill with oil to the right oil level or change the Drop in perfomances oil and the oil filter Inlet filters are dirty...
  • Page 22 HEADQUARTERS: Via Santa Vecchia, 107 - 23868 Valmadrera (LC), Italy T +39 0341 1918 51 - F +39 0341 1918 599 info@pvr.it - www.pvr.it LOCAL UNIT: Via IV Novembre, 104F 23868 Valmadrera (LC), Italy...
  • Page 23 EU 205 - EU 205/B EU 300 - EU 300/B Lubricated vane vacuum pump Technical data and parts lists Publication Number: RDT 1581.02 December 2017 TRANSLATION...
  • Page 24 Plaquette surfaces chaudes Typenschild für warme Fläche Placa superficies calientes Antivibranti Vibration damper Pied antivibratoire Schwingungsdämpfer Antivibrante Filtro olio Oil filter Filtre huile Ölfilter Filtro de aceite EU 205 - EU 205/B - EU 300 - EU 300/B RDT 1581.02...
  • Page 25 #Gültig für Temperaturen bis 40°C und für Höhen weniger als 1000 m. *Según la normativa Pneurop 6602. #Válido para temperaturas hasta 40°C y altitudes inferiores à 1000 m. RDT 1581.02 EU 205 - EU 205/B - EU 300 - EU 300/B...
  • Page 26 Technical data and parts lists EU 205 - EU 205/B - EU 300 - EU 300/B RDT 1581.02...
  • Page 27 Technical data and parts lists RDT 1581.02 EU 205 - EU 205/B - EU 300 - EU 300/B...
  • Page 28 Technical data and parts lists EU 205 - EU 205/B - EU 300 - EU 300/B RDT 1581.02...
  • Page 29 Technical data and parts lists RDT 1581.02 EU 205 - EU 205/B - EU 300 - EU 300/B...
  • Page 30 SEDE LEGALE E AMMINISTRATIVA: Via Santa Vecchia, 107 - 23868 Valmadrera (LC), Italy T +39 0341 1918 51 - F +39 0341 1918 599 info@pvr.it - www.pvr.it UNITÀ LOCALE: Via IV Novembre, 104F 23868 Valmadrera (LC), Italy...
  • Page 31 EU205F EU205F HWT EU300F EU300F HWT Lubricated vane vacuum pump Operating and maintenance instructions Publication Number: LI 4431.02 April 2021 TRANSLATION...
  • Page 32 Operating and maintenance instructions Index 1. General information ....................page 3 2. Product specifications ..................page 4 2.1 Pump description ..................... page 4 2.2 Expected use .....................page 5 2.3 Forbidden use....................page 5 2.4 Protections ......................page 5 2.5 Accessories .......................page 5 3. Safety rules ......................page 6 4.
  • Page 33: General Information

    Operating and maintenance instructions 1. General information This manual contains information necessary for the proper operation of the pump in order to prevent unsuitable use and for the safety of the operators. Do not attempt any other type of operation without having first contacted our Service Department. The information provided herewith does not intend to replace, integrate or change any rules, regulations, law by decree, directive or law of specific character in force in the Country where the installation takes place.
  • Page 34 Operating and maintenance instructions 2. Product specifications 2.1 Pump description EU300F - EU300F HWT pumps are single-stage, rotary vane lubricated vacuum pumps, with oil recirculation. The flanged electric motor is coupled by means of an elastic coupling. Cooling is achieved by means of an air/oil cooler and a centrifugal fan. At the pump inlet there is a mesh filter in order to protect it from solid parts having diameter larger than 1.5 mm.
  • Page 35 40°C. In case you get temperatures outside this range, please get in touch with us. Handling of other types of gas or vapours must be declared in advance to PVR that will give the conformity to the specific use.
  • Page 36 Operating and maintenance instructions 3. Safety rules WARNING: Despite of all the precautions adopted when designing the equipment, there are some risk elements that arise during operation and servicing. HOT SURFACES The temperature of the pump surfaces may exceed 80°C. Install the pump in a protected area accessible only by authorized personnel, to prevent possible personal injures due to contact with hot surfaces.
  • Page 37 Operating and maintenance instructions ELECTRIC SAFETY Some components of the electric equipment are electrically charged during operation. Any contact may cause serious injuries to persons or objects. Connection and control of the electric system must be carried out by skilled personnel only.
  • Page 38 In case of damages are found, inform immediately PVR and the carrier. A representative will contact you or it may be dispatched to the site to inspect and file full damage report.
  • Page 39 Operating and maintenance instructions 5. Installation and operation 5.1 Assembly If the pump is supplied without any electric motor, install a motor whose characteristics are the same as stated on the technical sheet, constructive form IM B 5. WARNING: - Use lifting equipment suitable for the motor weight (about 45 Kg 50 Hz and about 50 Kg 60 Hz) - To assure the continuity of the equipotential circuit of the pump, clean the contact surfaces very well, by removing any grease or protective painting.
  • Page 40 Operating and maintenance instructions 5.2 Location WARNING: The pump must be installed in a protected area (see safety rules). It must be fastened with support feet on horizontal surface. It must be accessible for correct and easy maintenance, by respecting the minimum distances from possible obstructions (see figure 6).
  • Page 41 Operating and maintenance instructions 5.3 Connection to the machine The connection to the chamber to be pumped down must be carried out by means of pipes of the same diameter as the inlet port. Pipe weights and expansions, if any, must not rest on the pump. It is advisable to make the final connection to the pump inlet port with flexible pipes or fittings.
  • Page 42 Operating and maintenance instructions 5.5 Electrical connection The control panel and electrical connections must be carried out by skilled personnel and conform to the EN 60204-1 rules or to other local regulations in the Country of use. The electrical equipment must comply with EN 61000-6-4 and EN 61000-6-2 standards concerning electromagnetic compatibility, emission standard and immunity for industrial environment.
  • Page 43 Operating and maintenance instructions 5.6 Commissioning The pump is supplied without lubricating oil. NOTE: the operation without oil causes big damages to the pump. Carry out the first filling up through the plug (E) up to the half of the sight glass (F) and close the plug (E) (Figure 8).
  • Page 44 Operating and maintenance instructions 5.8 Water vapour intake In order to pump down any water vapour, the following operations are recommended: Let the pump run for thirty minutes at the maximum vacuum in order to bring the pump temperature to its operating value. At the end of the working cycle, in case of further presence of condensate in the oil, let the pump run for at least thirty minutes at the maximum vacuum.
  • Page 45 Operating and maintenance instructions 6.1 General information In order to keep the pump operating at a high efficiency level, it is mandatory to follow all periodical service points listed in the table below.However, more frequent service operations may be necessary depending on what the pump is used for (suction of con- densable vapours, suction of powders or polluting substances).
  • Page 46 Operating and maintenance instructions 6.2 Oil change For a correct operation, oil change should be performed when the pump is still warm. WARNING: Use protective gloves to avoid injury caused by heat. Please refer to Figure 8, section 5.6. Unscrew the oil filling plug (E) and the discharge plug (G) only after having placed underneath the pump tank a suitable container (proper size and shape) for collecting the total quantity of oil.
  • Page 47 Operating and maintenance instructions 6.4 Exhaust filters replacement Very dirty exhaust filters may cause a considerable pump temperature increase and in extreme cases oil lubricant spontaneous ignition. Maximum allowed pressure in the tank is 0,6 bar measured at the maximum capacity (when the pump is working with the inlet open to atmospheric pressure).
  • Page 48 7. Lubricants Oil recommended for generic use Mineral oil for compressors according to DIN 51506 group VC-VCL or VDL classifica- tion ISO L-DAG. Ambient temperature Viscosity PVR oil 10 - 40°C ISO 100 Rotant VF 204 5 - 15°C ISO 68 Rotant VF 203 Oil recommended for heavy duty, both for high and low temperatures.
  • Page 49 9. Return for repair In case of pump return for repair to PVR, provide a list of substances which have come in contact with the pump and advise the risks involved in handling, if any. Drain the lubricant from the pump prior to shipping the pump back.
  • Page 50 Operating and maintenance instructions 11. Troubleshooting TROUBLE CAUSE REMEDY Inlet pipes or machine are leaking Identify leaking point and seal it Check oil level and oil conditions. No lubrication Fill with oil to the right oil level or change the Drop in perfomances oil and the oil filter Inlet filters are dirty...
  • Page 51 Operating and maintenance instructions LI 4431.02 (IT-EN)
  • Page 52 HEADQUARTERS: Via Santa Vecchia, 107 - 23868 Valmadrera (LC), Italy T +39 0341 1918 51 - F +39 0341 1918 599 info@pvr.it - www.pvr.it LOCAL UNIT: Via IV Novembre, 104F 23868 Valmadrera (LC), Italy...
  • Page 53 EU205F HWT EU300F HWT Lubricated vane vacuum pump Technical data and parts lists Publication Number: RDT 4429.01 April 2021 TRANSLATION...
  • Page 54 Technical data and parts lists (2xHWT) (2xHWT) (2xHWT) (2xHWT) (2xHWT) EU205F HWT - EU300F HWT RDT 4429.01...
  • Page 55 Technical data and parts lists EU 205F - HWT Portata nominale* 50Hz Nominal speed* Débit nominal* Nennsaugvermögen* 60Hz Caudal nominal* Pressione finale*(assoluta) ≤ 0,8 mbar Ultimate pressure* (abs.) Pression limite* (abs.) Enddruck* (abs.) ≤ 80 Pascal Presión final* (abs.) Potenza motore # / Numero di giri 50Hz ~3 Motor power # / Rotational speed 1500...
  • Page 56 Technical data and parts lists EU205F HWT - EU300F HWT RDT 4429.01...
  • Page 57 Technical data and parts lists RDT 4429.01 EU205F HWT - EU300F HWT...
  • Page 58 Technical data and parts lists EU205F HWT - EU300F HWT RDT 4429.01...
  • Page 59 Technical data and parts lists RDT 4429.01 EU205F HWT - EU300F HWT...
  • Page 60 Technical data and parts lists EU205F HWT - EU300F HWT RDT 4429.01...
  • Page 61 Technical data and parts lists POS. DESCRIPTION EU205F HWT EU205F HWT Body of pump External side cover Motor side cover Rotor Vane Oil seal ring cover Ø35/45x3 Spacer 6307 Bearing 63x80 Space washer Shim ring I53 Seeger IR 35X43X30 Ring 10x8x50 Key Ø6x30 Pin 2”G Inlet flange...
  • Page 62 Technical data and parts lists POS. DESCRIPTION EU205F HWT EU205F HWT M10 Nut (flanged and knurled) M10x55 Partially threaded Hex. Screw M12x35 Hex. Screw M6x12 Hex. (Screw flanged and knurled) M6x16 Hex. Screw (flanged and knurled) M8x16 Hex. Screw (flanged and knurled) M10x20 Hex.
  • Page 63 Min. oil level switch extension Max. oil level switch extension 1”G Oil level switch port 1/8”G Al washer 1”G Al washer PVR pressure gauge A10 M-F 1/8”-1/8”G fitting A5 M-F 1/8”-1/8”G extension A4/Z M-F 1/4”-1/8”G Adapter 1/4"G Al washer Adjustable pressure switch Oil filter condition indicator A5/Z M-F 1/8"-1/8"G Extension...
  • Page 64: Maintenance Kit

    Technical data and parts lists POS. DESCRIPTION EU205F HWT EU205F HWT Safety temperature switch 1/4"G Al washer 2”NPT Inlet flange ISO-K63 Inlet flange 2”NPT Discharge tank cover Oversized electric motor MAINTENANCE KIT R Minor maintenance kit S Major maintenance kit (R+G1+G2) G1 Viton sealing kit G2 Machined gasket kit EU205F HWT - EU300F HWT...
  • Page 65 SEDE LEGALE E AMMINISTRATIVA: Via Santa Vecchia, 107 - 23868 Valmadrera (LC), Italy T +39 0341 1918 51 - F +39 0341 1918 599 info@pvr.it - www.pvr.it UNITÀ LOCALE: Via IV Novembre, 104F 23868 Valmadrera (LC), Italy...

This manual is also suitable for:

Eu 205/bEu 300Eu 300/b

Table of Contents