8
|
Piping installation

8.3.2 Precautions when checking the refrigerant piping

8.3.3 Checking refrigerant piping: Setup

8.3.4 To check for leaks

Installer reference guide
110
If there is a possibility of moisture being present in the refrigerant piping (for
example, water may have entered the piping), first carry out the vacuum drying
procedure below until all moisture has been removed.
INFORMATION
Also read the precautions and requirements in the following chapters:
"2 General safety
"8.1 Preparing refrigerant
NOTICE
Use a 2-stage vacuum pump with a non-return valve that can evacuate to a gauge
pressure of −⁠ 1 00.7 kPa (−⁠ 1 .007 bar)(5 Torr absolute). Make sure the pump oil does
not flow oppositely into the system while the pump is not working.
NOTICE
Use this vacuum pump for R32 exclusively. Using the same pump for other
refrigerants may damage the pump and the unit.
NOTICE
Connect the vacuum pump to both the service port of the gas stop valve and the
service port of the liquid stop valve to increase efficiency.
Make sure that the gas stop valve and liquid stop valve are firmly closed before
performing the leak test or vacuum drying.
a
c
R32
N 2
b
d
a Pressure gauge
b Nitrogen
c Refrigerant
d Weighing scale
e Vacuum pump
f Stop valve
NOTICE
Do NOT exceed the unit's maximum working pressure (see "PS High" on the unit
name plate).
4
precautions" [
 10]
4
piping" [
 101]
f
e
ERRA08~12E + ELSH/X(B)12P30+50EG
Daikin Altherma 3 R MT ECH₂O
4P759885-1B – 2025.03

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Altherma 3 R MT ECH2O ERRA08E V3 Series and is the answer not in the manual?

This manual is also suitable for:

Altherma 3 r mt ech2o erra10e v3 seriesAltherma 3 r mt ech2o erra12e v3 seriesAltherma 3 r mt ech2o erra08e w1 seriesAltherma 3 r mt ech2o erra10e w1 seriesAltherma 3 r mt ech2o erra12e w1 seriesAltherma 3 r mt ech2o elsh12p30e series ... Show all

Table of Contents