Conveying the Cooler to the Roof Mounting the Cooler Cable Installation Installing the Venturi / Fan Assembly - CPQ, LCQ, TBQ, TBS, BMQ, LCQI, TBQI and TBSI Installing the Venturi / Fan Assembly - LPQI WATER REQUIREMENTS Installing the Float Valve - LPQI...
Min Water Pressure: 100kPa (15psi) Max Water Pressure: 800kPa (115psi) Seeley International provides the following information as a guide to contractors and employees to assist in minimising risk New hose sets supplied with the appliance are to be used and whilst working at height.
IMPORTANT SAFETY INSTRUCTIONS • Is there a system which prevents employees from working on roofs if they are unwell or under the influence of drugs or alcohol? • Are there any special conditions to consider i.e. excessive roof pitch, limited ground area, fragile roof, electrical power lines? OTHER IMPORTANT REQUIREMENTS •...
QUICK GUIDE Step 1 Step 2 Step 3 SAFETY COOLER LOCATION REMOVE VENTURI Read & understand the safety section. Check cooler location. Consider Press the clip or remove the screws on regulations. Discuss with customer. both sides of the venturi to release. Page 2 Page 6 Page 6...
Page 7
QUICK GUIDE cont. Step 4 Step 5 Step 6 REMOVE TRANSITION PREPARE THE DROPPER MOUNT DROPPER Press the clips inwards to release the Cut hole & fit the grommet in the dropper Position, level and secure the dropper. transition from the tank. for power and control cables.
For CPQ/LCQ/TBQ/TBS models, disengage the two venturi clips as shown. For BMQ, LCQI, TBQI, TBSI and LPQI, remove ACCESS FOR SERVICING AND MAINTENANCE the 2 screws securing the venturi to the tank.
REMOVING THE TRANSITION - CPQ, LCQ, TBQ, TBS, BMQ, LCQI, TBQI and TBSI Turn the cooler onto its side to remove the transition. There are clips in each of the four corners that will disengage once the transition is given a firm pull.
REMOVING THE TRANSITION - LPQI - cont. MOUNTING THE DROPPER - CPQ, LCQ, TBQ, TBS, BMQ, LCQI, TBQI and TBSI Lower the cooler gently back onto the tank in preparation for Install the dropper and securely fix it to the roof structure on 3 transport to the roof.
SECURING THE DROPPER AND TRANSITION - CPQ, MOUNTING THE DROPPER - LPQI LCQ, TBQ, TBS, BMQ, LCQI, TBQI and TBSI Fit the transition onto the dropper as shown. The dropper must be installed at a 22.5° angle for all roof pitches.
INSTALLATION INSTRUCTIONS cont. The transition can be used with a standard spirit level to EXTRA NOTES FOR LPQI MODELS ONLY achieve the required angle. INSTALLING THE SUPPORT BRACKETS Secure the transition (and support brackets) to the dropper using the screws provided. NOTE: Transition screw holes align with the support bracket holes.
WEATHERSEAL - LPQI ILL2600-B WEATHERSEAL - CPQ, LCQ, TBQ, TBS, BMQ, LCQI, Before installing the two (2) Weatherseal flaps, lay them side TBQI and TBSI by side so that the text “THIS SIDE UP” is visible. This is the ILL2600-B orientation in which they should be fitted to the transition.
TBQI and TBSI CPQ, LCQ, TBQ, TBS, BMQ, LCQI, TBQI and TBSI Models Important! There must be no obstructions to the Weatherseal opening fully as it will adversely affect the performance of the cooler.
Important! Pass the wall control cable through the conduit first. CPQ, LCQ, TBQ, TBS, BMQ, LCQI, TBQI and TBSI Models Lock the power cable socket in place by sliding the plug in sideways into the tank as shown. Now pass the cables through your main conduit and connect the main conduit to the conduit adaptor (under the transition).
INSTALLING THE VENTURI / FAN ASSEMBLY - CPQ, INSTALLING THE VENTURI / FAN ASSEMBLY - LPQI LCQ, TBQ, TBS, BMQ, LCQI, TBQI and TBSI Important! Ensure the plug/lead assembly is not caught under the bottom lip of the venturi during installation by holding it out of the way.
WATER REQUIREMENTS Installation of the cooler water supply must conform to LPQI Models local plumbing rules, regulations and standards. HOSE The following specifications for the cooler water supply are required: RUBBER Water Connection ½” BSP WASHER Min Water Pressure 100kPa (15psi) SOLENOID Max Water Pressure 800kPa (115psi)
WATER REQUIREMENTS cont. INSTALLING THE FLOAT VALVE - CPQ, LCQ, TBQ, TBS, BMQ, LCQI, TBQI and TBSI CPQ, LCQ, TBQ, TBS, BMQ, LCQI, TBQI and TBSI Models ILL414-C ILL993-B Clip the solenoid cover in place and connect the flexible hose to ILL985-E the mains water supply.
INSTALLING THE WATER SENSOR Connect the supplied cable to the solenoid valve, then push the CPQ, LCQ, TBQ, TBS, BMQ, LCQI, TBQI and TBSI Models other end through the hole in the solenoid cover before fitting Assemble the water sensor as shown by clipping the sensor to the solenoid cover to the tank.
WATER REQUIREMENTS cont. MAINS WATER CONNECTION BLEED FUNNEL For bleed funnel option, a 3/4” to 1/2” BSP adaptor is to be (Model Dependent – refer to your dealer) fitted with the washer to the extension tube as shown! The bleed funnel reduces the accumulation of salts and Connect the main water supply to the water inlet minerals in the cooler.
Important! The isolation switch cannot be activated unless this screw is fixed in place. Important! It is a requirement of Seeley International that all coolers be connected to a dedicated circuit to the distribution Switch OFF the electronics module before connecting any board, with a separate circuit breaker and incorporate means accessories.
For BMQ, CPQ, LCQ, TBQ & TBS models Route the drain valve cable as shown before connecting it to the electronics module (E). EXTRA NOTES FOR LCQI/LPQI/TBQI TYPE MODELS The plug connection points differ from BMQ/CPQ/LCQ & TBQ type models. WALL CONTROL SPARE...
Route the pump cord as shown. For BMQ, CPQ, LCQ, TBQ and TBS models Connect the pump plug (F) as shown. BMQ, CPQ, LCQ, TBQ, TBS, LCQI, TBQI and TBSI models LEGEND A - Control Cable B - Speed Adjustment...
ELECTRONICS MODULE” on page 27. parameter can be set to. Water Manager = 0 Timed Drain (CPQ/BMQ Upgrade Kits) = 1 Non-Drain Valve salinity control (bleed etc) = 2 5. To store the value, press “ ”. Screen will go blank momentarily as wall control stores parameter change, and returns screen to “A#”...
Wait for this to happen and check the water level. BMQ, CPQ, LCQ, TBQ, TBS, LCQI, TBQI and TBSI Models ILL997-C If the level is too high rotate the float clockwise. Drain some water from the tank and allow it to refill to the new set point.
COMMISSIONING THE COOLER TEST OPERATION BMQ, CPQ, LCQ, TBQ & TBS MODELS Check that the green light on the electronics module is on and REFITTING THE PAD FRAMES double flashing every 2 seconds. This indicates that power is Refit the pad frames by locating the bottom edge in the tank connected to the electronics module.
COMMISSIONING THE COOLER cont. BRAEMAR LPQI MODELS Once the rear pad frame is assembled, the 2 side pad frames can be fitted in the same way. REMOVING THE PAD FRAMES Ensure the clips between the rear and the side panels are fully The pad frames are designed to overlap and interlock and so engaged.
COMMISSIONING THE COOLER cont. TESTING THE PUMP POWER Test the pump by turning the cooler on at the controller, in □ REGULATIONS - The power supply adheres to all local and “COOL” mode. Check that water is evenly distributed to all national regulations and is wired back to the distribution board pads.
ADJUSTING COOLER SETTINGS FAULT CODES INDICATED BY LED’s ON THE COOLER ELECTRONICS MODULE Within the SETTINGS menu of the MagIQtouch Controller is the Fault Code 01 (1 Red Flash) = Communication Failure. COOLER sub-heading. Here various settings of the cooler can •...
TROUBLE SHOOTING Symptom Cause Action Inadequate cooling Under-sized cooler. Replace with larger cooler. Under-sized ducts. Carry out cooling load design to determine correct size unit, ducting and outlets required. Clogged or dirty cooling pads. Clean or replace pads. Dry pads or lack of water while cooler is operating. Check water distribution system for possible obstruction in hoses.
Page 32
For all other regions contact your local distributor seeleyinternational.com It is the policy of Seeley International to introduce continuous product improvement. Accordingly, specifications are subject to change without notice. Please consult with your dealer to confirm the specifications of the model selected.