Page 2
Introduction Industrial cybersecurity SIMATIC Product overview S7-1500R/H CPU 1513R-1 PN Connecting (6ES7513-1RM03-0AB0) Interrupts, diagnostics, error messages and system events Equipment Manual Technical specifications Dimension drawing 01/2024 A5E42009333-AE www.PLC1.ir...
Page 3
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Industry Mall The Industry Mall is the catalog and order system of Siemens AG for automation and drive solutions on the basis of Totally Integrated Automation (TIA) and Totally Integrated Power (TIP).
The documentation for the redundant S7-1500R/H system is arranged into three areas. This arrangement enables you to access the specific content you require. You can download the documentation free of charge from the Internet (https://support.industry.siemens.com/cs/ww/en/view/109742691). Basic information The System Manual and Getting Started describe in detail the configuration, installation, wiring and commissioning of the redundant S7-1500R/H system.
Changes and supplements to the manuals are documented in a Product Information. The Product Information takes precedence over the device and system manuals. You can find the latest Product Information on the redundant S7-1500R/H system on the Internet. (https://support.industry.siemens.com/cs/ww/en/view/109742691) Manual Collection S7-1500/ET 200MP The Manual Collection S7-1500/ET 200MP contains the complete documentation on the redundant S7-1500R/H system gathered together in one file.
Online Support: Industry Online Support International https://support.industry.siemens.com/cs/ww/en/view/109742705 Watch this short video to find out where you can find the overview directly in Siemens Industry Online Support and how to use Siemens Industry Online Support on your mobile device: Quick introduction to the technical documentation of automation products per video ( https://support.industry.siemens.com/cs/us/en/view/109780491...
Manuals, characteristics, operating manuals, certificates • Product master data You can find "mySupport" on the Internet. (https://support.industry.siemens.com/My/ww/en) Application examples The application examples support you with various tools and examples for solving your automation tasks. Solutions are shown in interplay with multiple components in the system - separated from the focus on individual products.
Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
Secure operation Corrective measures for known risks Corrective measures for known risks are announced on the Siemens ProductCERT (https://siemens.com/productcert) Web page. For more information on SIEMENS ProductCERT, refer to the System Manual (https://support.industry.siemens. com/cs/us/en/view/109754833). CPU 1513R-1 PN (6ES7513-1RM03-0AB0) Equipment Manual, 01/2024, A5E42009333-AE...
Page 12
Security checks Application-specific security measures such as cyclic checks of the configuration via checksums are described in the System Manual (https://support.industry.siemens. com/cs/us/en/view/109754833). Recording Security events Information on recording security events can be found in the "Safe operation of CPUs" section of the System Manual (https://support.industry.siemens.
Where can I find information? Power supply modules System power supplies (PS) supply the S7-1500R/H System Manual internal electronics of the S7-1500R/H (https://support.industry.siemens. modules with power via the backplane com/cs/ww/en/view/109754833) bus. The following system power supply modules are supported: •...
Page 14
Data exchange via OPC UA as server As of firmware version V3.1, the • S7-1500R/H System Manual S7-1500R/H redundant system supports (https://support.industry. siemens. data exchange as an OPC UA server. com/cs/ww/en/view/1097548 An OPC UA server provides information within a network, e.g. relating to the CPU, •...
Page 15
Can be enabled/disabled in the CPU prop Communication Function Manual A simple configuration option is available for erties. Community strings can be con (https://support.industry.siemens. use of SNMP services. For new configurations, figured. com/cs/ww/en/view/59192925) this is disabled by default in accordance with "Security-by-Default".
Page 16
Customer benefits Where can I find information? Simulation of R/H-CPUs PLCSIM Advanced V4.0 supports simulation of S7-PLCSIM Advanced Function Manual R/H-CPUs (https://support.industry.siemens. com/cs/ww/en/view/109773484) • Virtual commissioning of machines with R/H-CPUs in a system • Automatic testing of the STEP 7 user program The simulation offers the following advantages: •...
Page 17
You can download a modified user program into the S7-1500R/H System Manual program in RUN-Redund R/H CPUs in the RUN-Redundant system state. (https://support.industry.siemens. ant system state Advantage: The redundant system will remain consist com/cs/ww/en/view/109754833) ently in the RUN-Redundant system state during the change to the user program.
You mount the CPUs on a standardized 35 mm rail using the standard rail adapter. You will find information on mounting the standard rail adapter in the S7‑1500R/H redundant system (https://support.industry.siemens.com/cs/ww/en/view/109754833) System Manual. CPU 1513R-1 PN (6ES7513-1RM03-0AB0) Equipment Manual, 01/2024, A5E42009333-AE...
Product overview 3.2 Configuration and operating principle Principle of operation One of the two CPUs in the redundant system takes on the role of CPU for process control (primary CPU). The other CPU takes on the role of the following CPU (backup CPU). The assigned role of the CPUs can change during operation.
Product overview 3.3 Hardware properties Hardware properties Article number 6ES7513-1RM03-0AB0 View of the module The following figure shows the CPU 1513R-1 PN. Figure 3-2 CPU 1513R-1 PN NOTE Protective film Note that there is a removable protective foil on the display when the CPUs are delivered. CPU 1513R-1 PN (6ES7513-1RM03-0AB0) Equipment Manual, 01/2024, A5E42009333-AE www.PLC1.ir...
Page 21
All CPUs of the redundant system S7 1500R/H have a dis • Redundant System S7‑1500R/H play with plain text information. The display provides (https://support.industry.siemens. you with diagnostic messages as well as information com/cs/ww/en/view/109754833) about the article number, the firmware version and the System Manual serial number of the CPU.
Page 22
H‑Sync Forwarding when the "ApplicationClass" attribute contains the "HighAvailability" token. You will find additional information on H-Sync Forwarding in the S7-1500R/H Redundant Sys tem (https://support.industry.siemens.com/cs/ww/en/view/109754833) System Manual. Accessories You can find information on the topic of "Accessories/spare parts" in the Redundant System S7-1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833) System...
CPU redundancy There are two duplicate CPUs that synchronize their data Redundant System S7‑1500R/H via redundancy connections within a PROFINET ring. If (https://support.industry.siemens. one of the CPUs fails, the other CPU retains control of the com/cs/ww/en/view/109754833) Sys process. tem Manual...
Page 24
Integrated technology Integrated closed-loop con • PID Compact (continuous PID controller) PID control trol functionality (https://support.industry.siemens. • PID 3Step (step controller for integrating actuators) com/cs/ww/en/view/108210036) • PID Temp (temperature controller for heating and Function Manual cooling with two separate actuators) Controlling, measuring and •...
Additional information Password provider As an alternative to manual password entry, you can link Redundant System S7‑1500R/H a password provider to STEP 7. A password provider (https://support.industry.siemens. offers the following advantages: com/cs/ww/en/view/109754833) Sys tem Manual • Convenient handling of passwords. STEP 7 automatic...
Page 26
(local lock) and assign a password for the display. You can find additional information on the display, the configurable protection levels and the local lock in the Redundant System S7‑1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833) System Manual. Reference You can find detailed information on the individual display options, a training course and a simulation of the available menu commands in the SIMATIC S7‑1500 Display Simulator...
Product overview 3.5 Operator controls and display elements 3.5.2 Front view of the CPU without front flap and bottom view The following figure shows the operator controls and connection elements of the CPU 1513R-1 PN. ① LED displays for the current operating state and diagnostic status of the CPU ②...
Product overview 3.5 Operator controls and display elements ① Slot for the SIMATIC Memory Card ② PROFINET IO interface (X1) with 2 ports ③ Connection for supply voltage ④ Fastening screw Figure 3-6 View of the CPU 1513R-1 PN – bottom 3.5.3 Rear view of the CPU The figure below shows the connection elements on the rear of the CPU 1513R‑1 PN.
You can find a brief overview of the various operating states and system states in the section Status and error display of the CPU (Page 33). You can find a detailed description of the operating states and system states in the S7-1500R/H Redundant System (https://support.industry.siemens.com/cs/ww/en/view/109754833) System Manual. CPU 1513R-1 PN (6ES7513-1RM03-0AB0) Equipment Manual, 01/2024, A5E42009333-AE www.PLC1.ir...
1L+ and 2L+ as well as 1M and 2M are bridged internally Maximum 10 A permitted You can find information on the various supply options in the S7‑1500R/H redundant system (https://support.industry.siemens.com/cs/ww/en/view/109754833) System Manual. PROFINET interface X1 with 2-port switch (X1 P1R and X1 P2R) The assignment corresponds to the Ethernet standard for a RJ45 connector.
You can find more information on the topic of "Connecting the CPU" and on the topic "Accessories/spare parts" in the S7‑1500R/H redundant system (https://support.industry.siemens.com/cs/ww/en/view/109754833) System Manual. Assignment of the MAC addresses CPU 1513R‑1 PN has a PROFINET interface with two ports for each CPU. The PROFINET interface itself has a MAC address, and each of the two PROFINET ports has its own MAC address.
Connecting 4.1 Terminal assignment Block diagram The figure below shows the schematic circuit diagram of the CPU 1513R-1 PN. ① CPU with operating buttons and operat X80 DC 24 V Infeed of supply voltage ing mode buttons ② Electronics Supply voltage 24 V DC ③...
You can find more detailed information on "Interrupts" in the STEP 7 online help. You can find additional information on the topic of "Diagnostics" and "System events" in the Diagnostics (https://support.industry.siemens.com/cs/ww/en/view/59192926) Function Manual and in the Redundant System S7‑1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833) System Manual.
Page 34
Interrupts, diagnostics, error messages and system events 5.1 Status and error display of the CPU LED displays depending on operating states and system states CPU 1513R‑1 PN has the following LEDs for displaying the current operating state and diagnostics status. • RUN/STOP LED •...
Page 35
Interrupts, diagnostics, error messages and system events 5.1 Status and error display of the CPU Meaning of the RUN/STOP, ERROR and MAINT LEDs CPU 1513R‑1 PN has three LEDs for displaying the current operating state and diagnostics status. NOTE LED patterns of the redundant system S7 1500R Note that it is not always possible to: •...
Page 36
Interrupts, diagnostics, error messages and system events 5.1 Status and error display of the CPU RUN/STOP LED ERROR LED MAINT LED Meaning Active Force job LED off LED lit green LED lit yellow The CPU is in operating state RUN-Redundant. LED off LED off There are no events, requirements, errors, etc.
Page 37
Interrupts, diagnostics, error messages and system events 5.1 Status and error display of the CPU LINK TX/RX LED Meaning The CPU performs an LED flash test. Flashes green There is an Ethernet connection between the PROFINET interface of your PROFINET device and a communication partner.
Technical specifications The following table shows the technical specifications as of 01/2024. You can find a data sheet including daily updated technical specifications on the Internet (https://support.industry.siemens.com/cs/ww/en/pv/6ES7513-1RM03-0AB0/td?dl=en). Article number 6ES7513-1RM03-0AB0 General information Product type designation CPU 1513R-1 PN HW functional status...
Page 39
Technical specifications Article number 6ES7513-1RM03-0AB0 Memory Number of slots for SIMATIC memory card SIMATIC memory card required Work memory • integrated (for program) 600 kbyte • integrated (for data) 2.5 Mbyte Load memory • Plug-in (SIMATIC Memory Card), max. 32 Gbyte Backup ...
Page 40
Technical specifications Article number 6ES7513-1RM03-0AB0 Nesting depth • per priority class Counters, timers and their retentivity S7 counter Number 2 048 • Retentivity adjustable – IEC counter • Number Any (only limited by the main memory) Retentivity ...
Page 41
Technical specifications Article number 6ES7513-1RM03-0AB0 Subprocess images • Number of subprocess images, max. Hardware configuration Number of distributed IO systems 16; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET, but also by the connection of I/O via IE/PB-Links.
Page 42
Technical specifications Article number 6ES7513-1RM03-0AB0 PROFINET IO Controller Services Isochronous mode – – – PROFIenergy Yes; per user program – Number of connectable IO Devices, max. – Updating times The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data –...
Page 43
Technical specifications Article number 6ES7513-1RM03-0AB0 SIMATIC communication • PG/OP communication Yes; encryption with TLS V1.3 pre-selected • S7 routing • S7 communication, as server • S7 communication, as client Open IE communication • TCP/IP Data length, max. 64 kbyte –...
Page 44
Technical specifications Article number 6ES7513-1RM03-0AB0 OPC UA • Runtime license required • OPC UA Client • OPC UA Server Yes; Data access (read, write, subscribe), method call, custom address space – Application authentication Security policies available security policies: None, Basic128Rsa15, –...
Page 45
Technical specifications Article number 6ES7513-1RM03-0AB0 Test commissioning functions Joint commission (Team Engineering) Status block Yes; up to 8 simultaneously Single step Number of breakpoints 8; Breakpoints are only supported in RUN-Solo status Status/control • Status/control variable • Variables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters •...
Page 46
Technical specifications Article number 6ES7513-1RM03-0AB0 Standards, approvals, certificates Suitable for safety functions Ambient conditions Ambient temperature during operation • horizontal installation, min. -30 °C; No condensation • horizontal installation, max. 60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off vertical installation, min.
336 g General technical specifications You can find information on the general technical specifications, such as standards and approvals, electromagnetic compatibility, protection class, etc. in the S7‑1500R/H redundant system (https://support.industry.siemens.com/cs/ww/en/view/109754833) System Manual. CPU 1513R-1 PN (6ES7513-1RM03-0AB0) Equipment Manual, 01/2024, A5E42009333-AE www.PLC1.ir...
Dimension drawing This section contains the dimensional drawing of the module on the mounting rail, as well as a dimensional drawing with the front flap open. Keep to the dimensions when installing in cabinets, control rooms, etc. Dimension drawings of the CPU 1513R-1 PN Figure A-1 Dimension drawing of the CPU 1513R-1 PN, front and side view Figure A-2 Dimension drawing of the CPU 1513R-1 PN, side view with front flap open CPU 1513R-1 PN (6ES7513-1RM03-0AB0)
Need help?
Do you have a question about the SIMATIC S7-1500R/H and is the answer not in the manual?
Questions and answers