  • Page 1 USER MANUAL OFF-Grid Single Phase Hybrid Inverter DOA01-5K_XFM5K-US Document version: 0 1...
  • Page 2: Table Of Contents

    Contents Preface Contents 1. ABOUT THIS MANUAL ......................1 1.1 Purpose ..............................1 1.2 Scope ................................. 1 2. SAFETY INSTRUCTIONS ......................1 3. INTRODUCTION ........................2 3.1 Features ..............................2 3.2 Basic System Architecture ........................2 3.3 Product Overview ............................ 3 4.
  • Page 3: About This Manual

    1. ABOUT THIS MANUAL 3. INTRODUCTION 1.1 Purpose This is a multi-function product , combining functions of inverter, solar charger and battery charger to offeruninterruptible power support with portable size. its comprehensive LCD display offers user-configurable and easy.accessible button operation such as battery charging current, AC/solar This manual describes the assembly, installation, operation and troubleshooting of this unit, Please charger priority, and acceptable inputvoltage based on different applications.
  • Page 4: Product Overview

    3.3 Product Overview 676mm 4. INSTALLATION 173mm 650mm Product Size 160mm 610mm 4.1 Unpacking and inspection Before installation, please inspect the unit, Be sure that nothing inside the package is damaged. You should have received the following items inside of package: 2mm hanging user manual ×1 M5*10X4...
  • Page 5: Ac Input/Output Connection

    Model Gauge Cable(mm²) Torque Value 4.4 PV Connection DOA01-5K_XFM5K-US 7AWG 1.2 Nm CAUTlON: Before connecting to PV modules, please install separately a DC circuit breakerbe- tweenPV connection terminal and PV modules. Timely protection in case of malfunction. Please follow below steps to implement AC input/output connection WARNING! All wiring must be performed by a qualified personnel.
  • Page 6: Operation

    Please follow the steps below to connectthe photovoltaic modules: 5. OPERATION 1. After installing the photovoltaic connection line using the matching MC4 connector,insert the positive terminal (+) of the MC4 connector into the positive terminal (+) ofthe PV input connecto- 5.1 Power ON/OFF rand then insert the positive terminal (+) of the MC4 connectorinsert the pole (-) into the negative pole (-) ofthe PVinput connector.
  • Page 7: Lcd Display Lcons

    5.3. LCD Display lcons Battery Information Indicates battery level by 0-24%,25-49%,50-74%,75-100% in battery mode and charging status in line mode. CHARGING In AC Model, It Will Present Battery Charging Status Status Battery Voltage LCD Display < 2V/cell Four bars will flash in turns Constant current 2~2.083V/cell Bottom bar will be on and other three bars flash in turns...
  • Page 8 Display Page 2 : Display the PV input and output voltage, as shown in Figure 1-2. Mode Operation Information indicates unit connects to the mains. Indicates unit connects to the PV panel. BYPASS Indicatesload is powered by utility power. indicates the load charger circuit is working Indicates the DC/AC inverter circuit is working Mode Operation Indicates unit alarm is disabled...
  • Page 9 Display Page 5 : Battery information, display the battery charging current and output voltage , as Display Page 8 : Battery information,display the battery voltage and output frequency, as shown in shown in Figure 1-5. Figure 1-8. Figure 1-5 display page 5 Figure 1-8 display page 8 Display Page 6 : Battery information, display the battery charging power and output voltage , as Display Page 9 : Battery Information, display the battery voltage and load percentage, as shown in...
  • Page 10 Display Page 11 : Battery information, display the battery voltage and output power, as shown in Display Page 14 : Lithium battery temperature, SOC; when the BMS communication successfully, Figure 1-11. the upper left corner displays BMS temperature information; the upper right corner displays BMS SOC information,as shown in Figure 1-14.If the BMS communication fails, this page is not available.
  • Page 11: Lcd Setting

    5.4 LCD setting Program Selectable option Description LCD display information switching is achieved by pressing the "Up" or "Down" button. The optionalinformation switching commands are as follows:Press and hold the button for 3 seconds Constant voltage charging voltage is [05] AGM and the device will enter the setting mode.
  • Page 12 Program Program Selectable option Selectable option Description Description [22] AON Setting voltage point Alarm on (default) back to battery mode [13] 54V Beeps while primary Setting range is from 48-58V when selecting “SBU (default) source is interrupted priority" in program 01. [16] CUT Alarm on Overload bypass:When...
  • Page 13: Operating Mode Description

    Program Selectable option Description Operation mode LCD display Operation mode [33] 60 Charging by utility and PV energy Setting range is from 5mins to 900mins. Standby mode/Power Battery equalized time mins save mode Increment of each click is 5mins. (default) Note: [34] 120 CHARGING...
  • Page 14: Battery Equalization Description

    Equalization also helps to remove sulfate crystals that might have built up on the plates. lf left Operation mode LCD display Operation mode unchecked,this condition, called sulfation, will reduce the overall capacity of the battery. Therefore, it's recommendedto equalize battery periodically. If "solar first"...
  • Page 15: Fault Code

    However, in Equalize stage, when battery equalized time is expired and battery voltage doesn't rise tobattery equalization voltage point, the charge controller will extend the battery equalized time Bus voltage is too high until battery voltageachieves battery equalization voltage. lf battery voltage is still lower than battery equalization voltage whenbattery equalized timeout setting is over, the charge controller will stop equalization and return to float stage.
  • Page 16: Warning Indicator

    This dry contact could be used to deliver signal to external 5.8 Warning indicator device when battery voltagereaches warning level. 1.In normal,NC-C close,NO-C open Fault 2.When battery voltage reach to low voltage disconnect Warning Event Audible Alarm Icon on Code point,NO-C close,NC-C open,at thistime, the NO-C point can drive the resistive load of 125VAC/0.5A and 30VDC/2A Fan is locked when inverter is on.
  • Page 17: Usb Communication

    BMS port:RJ45 7. CLEARANCE AND MAINTENANCE FOR ANTI-DUST KIT 1 2 3 4 5 6 7 8 7.1 Overview Every product is already installed with anti-dusk kit from factory.product wil automatically detect this kiandactivate internal thermal sensor to adjust internal temperature. This kit also keeps dusk from youroroductinternal and increases product reliability in harsh environment.
  • Page 18: Specifications

    8. SPECIFICATIONS FrequenCy 50Hz/60HZ Utility Charging Battery type Lithium/Lead-acid Model DOA01-5K_XFM5K-US Max. charging current Line Mode Charging current error range ± 5Adc Nominal input Voltage 110/120Vac Charging Voltage range 40-58.4Vdc Input Voltage Range (90Vac~140Vac)±2% Short Circuit Protection Breaker&fuse Nominal input Frequency...
  • Page 19: Trouble Shooting

    When the unit isturned Battery parameters LCD display and LEDS Battery is disconnected. Check if battery wires on, internalrelay is Battery Type LiFePO4 are flashing. are connected well. switched onand off Capacity 100Ah repeatedly. Nominal voltage 52Vdc Overload error. Reduce the connected Fault code 07 Theinverter is overload load byswitching off some...
  • Page 20: Approximate Back-Up Time Table

    Appendix: Approximate Back-up Time Table Modei Load(VA) Backup Time @ 48Vdc 100Ah (min) 1000 1500 2000 2500 3000 3500 4000 4500 5000...