Congratulations on purchasing your new Lancaster Water Filter. This unit is designed to give you
many years of trouble free service. For servicing and future inspection purposes, please file this
booklet with your important documents.
In the event that you need assistance for servicing your water filter, please first contact the
professional contractor who installed the system.
AND SERVICE MANUAL
COLOR, TASTE, ODOR
7-lx125F-CT-2B
7-lx125F-CT-3B
7-lx125F-CT-4B
COLOR, TASTE, ODOR
(CHLORAMINES)
7-lx125F-CaT-2B
7-lx125F-CaT-3B
7-lx125F-CaT-4B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XFACTOR Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lancaster XFACTOR Series

  • Page 1 7-lx125F-sT-2B 7-lx125F-sT-3B 7-lx125F-sT-4B Congratulations on purchasing your new Lancaster Water Filter. This unit is designed to give you many years of trouble free service. For servicing and future inspection purposes, please file this booklet with your important documents. In the event that you need assistance for servicing your water filter, please first contact the...
  • Page 2: Table Of Contents

    TAbLE OF CONTENTS Job specifications ......................... 2 Components ..........................2 Pre-Installation Review ......................... 3 General Installation and service Warnings .................. 3 Bypass Valve Operation ....................... 4 Installation Instructions, diagrams ....................5, 6 Placing Filter into service ......................7 General Operation ........................7 set Time of day ..........................
  • Page 3: Pre-Installation Review

    GENERAL INSTALLATION PRE-INSTALLATION AND SERVICE WARNINGS REVIEW The control valve, fitting and/or bypass are designed to WATER PRESSURE: a minimum of 20 pounds of water accommodate minor plumbing misalignments but are pressure (psi) is required for backwash. maximum 100 not designed to support the weight of a system or the psi.
  • Page 4: Bypass Valve Operation

    byPASS VALVE The bypass valve is typically used to isolate the control valve from the plumbing system’s water pressure in order to perform control valve repairs or maintenance. The x-Factor bypass valve is particularly unique in the water treatment industry due to its versatility and state of the art design features.
  • Page 5: Installation Instructions, Diagrams

    INSTALLATION INSTRUCTIONS (All electrical & plumbing should be done in accordance to all local codes) 1. Place filter in desired location close to water supply inlet, after pressure tank, and near a source for waste water, (utility sink, floor drain or sewer line). a 120V, 60Hz uninterrupted outlet is required. Keep filter far enough away from walls and other obstructions to allow enough room for servicing the unit.
  • Page 6 7-LX125F-CT, 7-LX125F-DAN, 7-LX125F-IM, 7-LX125F-ST INSTALLATION INSTALLATION MINIMUM 10 FEET OF PIPE OUTSIDE LOCATE WATER FILTER CLOSE TO A DRAIN. BETWEEN AVOID OVERHEAD DRAIN LINES IF POSSIBLE TO WATER FILTER OUTLET PREVENT BACK PRESSURE ON THE SYSTEM. WATER HEATER INLET HARD PIPING A 3/4" DRAIN LINE IS RECOMMENDED FOR UP TO 10 GPM BACKWASH RATE.
  • Page 7: Placing Filter Into Service

    PLACING FILTER INTO SERVICE do not plug the transformer into the receptacle yet. make sure inlet and outlet valves are to their closed positions. If using optional bypass, place in bypass position. Turn on main water supply. Open a cold water faucet. This will clear the line of any debris (solder, pipe dope, etc.) that may be in the line.
  • Page 8: Set Time Of Day

    SET TIME OF DAy Current time of day needs to be entered during initial installation, and adjusted when daylight saving time begins or ends. If an extended power outage occurs and depletes the on-board non-rechargeable coin cell battery, when power resumes the time of day should be reset and battery replaced.
  • Page 9: Low Battery

    LOW bATTERy a non-rechargeable coin cell battery is located on the circuit board, used only to maintain the time of day during power outages (all other information will be stored in memory no matter how long the power outage). The screen displays lOW BaTTERY when the battery needs to be replaced.
  • Page 10: Parts Diagrams

    X-FACTOR FRONT COVER AND DRIVE ASSEMbLy drawing no. Order no. description Quantity V3692-02lW lP Front Cover assembly V3107-01 motor V3106-01 drive Bracket & spring Clip V3757lP-BOaRd PC Board V3110 drive Gear 12x36 V3109 drive Gear Cover When replacing the battery, align Correct positives and push down to fully seat.
  • Page 11: Injector Cap, Injector Screen, Injector, Plug And O-Ring

    DRIVE CAP ASSEMbLy, DOWNFLOW PISTON, REGENERANT PISTON AND SPACER STACK ASSEMbLy drawing Order no. description do not use Vaseline, oils, other hydrocarbon lubricants or spray silicone anywhere. a silicone lubricant may be used on black o-rings but is not necessary. Avoid any V3430 spacer stack assembly type of lubricants, including silicone, on the clear...
  • Page 12: Water Meter

     bRINE REFILL PLUG      drawing no. Order no. description  H3195 Refill Port Plug assy H4615 Elbow locking Clip      WATER METER drawing no. Order no. description  V3151 nut 1” QC V3003* meter assy V3118-01 Turbine assy...
  • Page 13: Drain Line

    V3162-090 WS1 DLFC 9.0 gpm for ¾ V3162-100 WS1 DLFC 10.0 gpm for ¾ *4 and 6 can be ordered as a complete assembly - V3331 WS1 Drain Elbow and Retainer Asy Valves are shipped without drain line Á ow control (DLFC) - install DLFC before using. Valves DRAIN LINE - 3/4”...
  • Page 14: Installation Fitting Assemblies

    INSTALLATION FITTING ASSEMbLIES Order no: V3007-05 Order no. V3191-01 (Optional) description: Fitting 1-¼” Plastic Male NPT Assembly description: Fitting Vertical Adapter Assembly drawing Order description Quantity drawing Order description Quantity V3151 nut 1” Quick Connect V3151 nut 1” Quick Connect V3150 split Ring V3150 split Ring...
  • Page 15: Service Spanner Wrench

    SERVICE SPANNER WRENCH (Order no. V3193) although no tools are necessary to assemble or disassemble the valve, the wrench (shown in various positions on the valve) may be purchased to aid in assembly or disassembly. Loosens Injector And bypass Caps Loosens Drive Cap PaGE 15...
  • Page 16 OPTIONAL INSTALLATION FITTING ASSEMbLIES Order no: V3007-03 Order no: V3007-01 Order no: V3007-02 description: Fitting ¾” brass Sweat Assembly description: Fitting ¾” & 1” PVC Solvent 90° description: Fitting 1” brass Sweat Assembly Assembly drawing drawing Order Order no. description Quantity description Quantity...
  • Page 17: Service Instructions

    SERVICE INSTRUCTIONS ACID NEUTRALIZERS: mineral used: Calcite. Calcite will dissolve in proportion to the amount of acid in the raw water. The amount of calcite in the tank should be monitored and replaced periodically. a tank with a dome plug is provided so that calcite may be added without removing the control valve.
  • Page 18 Replace broken or damaged drive gears. do not lubricate any of the gears. avoid getting any foreign matter on the reflective coating because dirt or oils may interfere with pulse counting. The drive gear cover only fits on one way, with the large clip orientated towards the bottom. If all three clips are outside of the gear shroud on the drive bracket the drive gear cover slips easily into place.
  • Page 19 REFILL FLOW CONTROL ASSEMbLy: To clean or replace the refill flow control, pull out the elbow-locking clip and then pull straight up on the elbow. Replace the elbow locking clip in the slot so that it is not misplaced. Twist to remove the white flow control retainer. The flow control can be removed by prying upward through the side slots of the retainer with a small flat blade screwdriver.
  • Page 20: Troubleshooting

    TROUbLESHOOTING Problem Possible Cause Solution a. no power at electric outlet a. Repair outlet or use working outlet b. Control valve Power adapter not plugged b. Plug Power adapter into outlet or into outlet or power cord end not connect power cord end to PC Board connected to PC board connection connection 1.
  • Page 21 Problem Possible Cause Solution a. Bypass valve is open or faulty a. Fully close bypass valve or replace b. media is exhausted due to high water b. Check program settings or diagnostics usage for abnormal water usage c. meter not registering c.
  • Page 22 Problem Possible Cause Solution a. motor failure during a backwash a. Check motor connections then Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC Board for 5 seconds and then reconnect. b.
  • Page 24 OF C-B TOOl CO. 1340 manHEIm PIKE ● lanCasTER Pa 17601-3196 ● TEl:717-397-3521 ● Fax: 717-392-0266 www.lancasterwatertreatment.com ● E-mail: info@lancasterpump.com 5/25 PaGE 24...